Amprobe 35XP-A Digital Multimeter is for HVAC, plant maintenance technicians and residential electricians with Voltec non-contact voltage detection. It lets you instantly detect dangerous ac line voltages.
Characteristics
Chracteristics:Amprobe 35XP-A Digital Multimeter with NCV Detection
 VolTect non-contact voltage sensor and magnetic holster included
 4000-count screen resolution
 Temp. measurement capability up to 1000 Degrees C/1832 Degrees F, with an included type K thermocouple.
 Has the highest voltage-rating in this class of meter: 750 Volt ac current/1000 Volt dc current
 Motor run/start capacitance tests
 Flame testing resolution at 0.1 μ
 20 Megahertz frequency, and resistance to 20 mA
 Stability beeper
 Hold button to freeze the currently displayed reading
Description
Amprobe 35XP-A Digital Multimeters have multiple features and are compact. They have two unique accessories that are included: Voltec and our exclusive Magne-Grip Holster. Every DMM includes features that make your testing safer, easier, and more effective. This tool can be used in multiple applications, whether it be in field service, electronic repair, electrical or HVAC.
Specifications
Specifications: Amprobe 35XP-A Digital Multimeter
DC Volts Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V Resolution 100 μV Accuracy +/-(0.5 % rdg + 1 dgt) Input impedance 400 mV: >100 MΩ Input impedance 4 V: 10 MΩ Input impedance 40 V ~ 1000 V: 9.1 MΩ Overload protection 1000 VDC or 750 VAC rms
AC Volts (45 Hz - 500 Hz) Ranges 400 mV, 4 V, 40 V, 400 V, 750 V Resolution 100 μV Accuracy 45 Hz ~ 100 Hz on 400 mV range +/-(1.5 % rdg + 5 dgts) Accuracy on 4 V to 750 V ranges +/-(1.5 % rdg + 5 dgts) Input impedance 400 mV: >100 MΩ Input impedance 4 V: 10 MΩ Input impedance 40 V ~ 1000 V: 9.1 MΩ Overload protection 1000 VDC or 750 VAC rms
DC Current Ranges 400 μA, 4000 μA, 40 mA, 400 mA, 2 A Resolution 0.1 μA Accuracy on 400 μA to 400 mA ranges +/-(1.0 % rdg + 2 dgt) Accuracy on 2 A range +/-(2.0 % rdg + 3 dgts) Input protection 2 A/1000 V fast blow ceramic fuse 6.3_32 mm on A input Burden voltage 500 mV max. (2 V max. on 4 mA, 400 mA ranges)
AC Current (45 Hz - 500 Hz) Ranges 400 μA, 4000 μA, 40 mA, 400 mA, 2 A Resolution 0.1 μA Accuracy on 400 μA to 400 mA ranges +/-(1.5 % rdg + 5 dgts) Accuracy on 2 A range +/-(2.5 % rdg + 5 dgts) Input protection 2 A/1000 V fast blow ceramic fuse 6.3 x 32 mm on A input Burden voltage 500 mV max. (2 V max. on 4 mA, 400 mA ranges)
Resistance Ranges 400 Ω, 4 kΩ, 40 kΩ, 400 kΩ, 4 MΩ, 40 MΩ Resolution 100 mΩ Accuracy on 400 Ω to 4 MΩ ranges +/-(1.0 % rdg + 4 dgts) Accuracy on 40 MΩ range +/-(2.0 % rdg + 5 dgts) Open circuit volts 0.45 V dc typical, (-1.2 Vdc on 400 Ω range) Overload protection 1000 VDC or 750 VAC rms
Capacitance Ranges 4 nF, 40 nF, 400 nF, 4 μF, 40 μF, 400 μF, 4 mF Resolution 1 pF Accuracy on 4 nF to 4 μF ranges +/-(5.0 % rdg + 30 dgts) Accuracy on 40 μF to 400 μF ranges +/-(5.0 % rdg + 5 dgts) Accuracy on 4 mF ranges +/-(5.0 % rdg + 15 dgts) Test voltage < 1 V Test frequency on 4 nF to 40 μF ranges 1.3 Hz Test Frequency on 400 μF, 4 mF ranges 0.7 Hz Input protection 2 A/1000 V fast blow ceramic fuse 6.3 x 32 mm on A input
Temperature Ranges -20 - 1000 Degrees C, -4 - 1832 Degrees F Resolution 0.1 Degrees C, 0.1 Degrees F Accuracy -20 - 10 Degrees C +/-(2.0 % rdg + 4 Degrees C) Accuracy 10 - 200 Degrees C +/-(1.0 % rdg + 3 Degrees C) Accuracy 200 - 1000 Degrees C +/-(3.0 % rdg + 2 Degrees C) Accuracy -4 - 50 Degrees F +/-(2.0 % rdg + 8 Degrees F) Accuracy 50 - 400 Degrees F +/-(1.0 % rdg + 6 Degrees F) Accuracy 400 - 1832 Degrees F +/-(3.0 % rdg + 4 Degrees F) Overload protection 1000 VDC or 750 VAC rms
Frequency Ranges 4 k, 40 k, 400 k, 4 M, 40 MHz Resolution 1 Hz Accuracy +/-(0.1 % rdg + 3 dgts) Sensitivity 10 Hz ~ 4 MHz: >1.5 V rms Sensitivity 4 MHz ~ 40 MHz: >2 V rms, <5 V rms Minimum pulse width > 25 ns Duty cycle limits > 30 % and < 70 % Overload protection 1000 VDC or 750 VAC rms
Continuity Audible indication Less than 25 Ω Response time 100 ms Overload protection 1000 VDC or 750 VAC rms
Diode Test Test current 1.2 mA (approximate) Accuracy +/-(1.5 % rdg + 3 dgts) Resolution 1 mV Open circuit volts 3.0 dc typical Overload protection 1000 VDC or 750 VAC rms
Non-Contact Voltage Indicator Sense voltage 70 V to 600 VAC beeper chirps and big bright red LED comes on, works on all ranges
Display 3-3/4 digit liquid crystal display (LCD) with a maximum reading of 3999
Polarity Automatic, positive implied, negative polarity indication
Overrange (OL) or (-OL) is displayed
Zero Automatic
Low battery indication The low battery icon is displayed when the battery voltage drops below theoperating level
Auto power off Approx. 10 minutes
Measurement rate 2 times per second, nominal
Operating environment 0 to 50 Degrees C at <70 % R.H.
Storage temperature -20 to 60 Degrees C, 0 to 80 % R.H. with battery removed from meter
Accuracy Stated accuracy at 23 Degrees C +/- 5 Degrees C, <75 % relative humidity
Temperature coefficient 0.1 x (specified accuracy) per Degree C. (0 to 18 Degrees C, 28 to 50 Degrees C)
Altitude 6561.7 feet (2000 M)
Power Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life 150 hours typical with carbon-zinc, 300 hours typical with alkaline
Dimensions 155 mm (H) x 72 mm (W) x 32 mm (D)
Weight Approx. 400 g including battery
Safety Designed to meet IEC 1010-1, Rev-2 CAT I 1000V, CAT II 600V,CAT III 300V,Designed to meet IEC 1010-1, Rev-2 CAT I 1000V, CAT II 600V,CAT III 300V, class 2 and pollution degree 2 indoor use. Complies with CE and CSA 22.2 No. 1010-1 requirements.
Auxiliary Features Data hold Freeze the latest reading on the display; Range Execute manual range mode; AUTO power off; After auto power off, press any button to restart the meter, and the last reading of measurement will be maintained in the display; Jack Input warning detects wrong connection
Temperature coefficient 0.1 x (specified accuracy) per Degree C (0 to 18 Degrees C, 28 to 50 Degrees C)
Power Single standard 9 volt battery, NEDA 1604, JIS 006P, IEC 6F22
Battery life 200 hours typical with carbon-zinc
Weight Approx. 210 g including battery
Safety Designed to meet IEC 1010-1, Rev-2 CAT I 1000 V, CAT II 600 V,CAT III 300 V, class 2 and pollution deg. 2 indoor use. Complies with CE,and CSA 22.2 No. 1010-1 requirements
Auxiliary Features Data hold Freeze the latest reading on the displayRange Execute manual range modeAuto power off After auto power off, press (RANGE), (HOLD) button to restart the meter,and the last reading of measurement will be maintained in the displayA jack Input warning detects wrong connection