Fluke TiS60 Advanced Thermal Infrared Camera is the seventh in a new series of economical and highly-effective thermal imagers that provide a wide range of important standard features and some excellent new innovations. The Fluke TiS60 provides a solid 260x195 thermal resolution, a speedy 9 Hz refresh rate, a convenient and easy-to-use fixed-focus design, Fluke's exclusive IR-Fusion Blending and Picture-in-Picture technology, video recording capability, a built-in laser pointer and an impressive 417:1 distance to spot ratio for high accuracy. Additionally, the TiS60 is Fluke Connect compatible which allows wireless connection to the Fluke Connect App for advanced real-time reporting and synchronization with a wide range of Fluke Connect devices including multimeters and much more. Saved images are stored in the 4GB on-board memory and can also be saved to the Fluke Cloud ensuring no measurement data is lost.
Characteristics: | Fluke TiS60 Advanced Thermal Infrared Camera |
Simple point-and-shoot operation | |
260x195 resolution (50,700 pixels) offers quality images at an affordable price | |
Fluke exclusive IR-Fusion mode and Picture-in-Picture | |
Laser pointer targeting | |
Radiometric video recording | |
Impressive distance-to-spot ratio of 417:1 | |
3.5in full color LCD display at 320x240 pixels | |
High Temp range of -20 °C to 550 °C (–4 °F to 1022 °F) | |
Built-in 5 megapixel digital camera | |
Smart Battery system clearly displays remaining battery power | |
Fluke Connect compatible for easy and fast on-the-job reporting | |
4 GB internal memory and optional 4 GB micro SD card stores thousands of images | |
Includes: | Thermal imager, AC charger/power supply with mains adapters for battery charging and AC operation, One rugged lithium ion smart battery, Soft transport bag, Statement of factory calibration, Quick start guide, Safety sheet |
Specifications: | Fluke TiS60 Advanced Thermal Infrared Camera |
Key Features | |
IFOV (spatial resolution) | 2.4 mRad |
Detector resolution | 260x195 |
Field of view | 35.7 ° x 26.8 ° |
Distance to spot | 417:1 |
Wireless connectivity | Yes |
Fluke Connect app compatible | Yes (where available) |
IR-Fusion Technology | |
AutoBlend mode | 5 presets (0%, 25%, 50%, 75%, 100%) |
Picture-In-Picture (PIP) | 5 presets (0%, 25%, 50%, 75%, 100%) |
Focus system | Fixed focus, Minimum focus distance 0.45 m (1.5 ft) |
Ruggedized display | 3.5 inch (landscape) 320x240 LCD |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | = 0.08 °C at 30 °C target temp (80 mK) |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +550 °C (–4 °F to 1022 °F) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (manual mode) | 2.5 °C |
Minimum span (auto mode) | 5 °C |
Built-in digital camera (visible light) | 5 MP |
Frame rate | 9 Hz |
Laser Pointer | Yes |
Data storage and Image Capture | |
Extensive SD memory system | Internal 4 GB (optional 4 GB micro SD card sold separately) |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Image file formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric (.bmp, .jpg) files |
Instant Upload | Instantly upload captured images to Fluke Connect server with the use of a WiFi connection |
Memory review | Thumbnail review |
Software | SmartView software - full analysis and reporting software and Fluke Connect (where available) |
Export file formats with SmartView software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
IR-PhotoNotes | Yes (3 images) |
Standard video recording | Yes |
Radiometric video recording | Yes |
Video file formats | Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
Streaming video (remote display) | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | One lithium ion smart battery pack with five-segment LED display to show charge level |
Battery life | Four+ hours |
Battery charge time | 2.5 hours to full charge |
Battery charging system | In-imager charging (optional external charger sold separately) |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Temperature Measurement | |
Accuracy | ±2 °C or 2% (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Color Palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High-Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra Contrast palettes | 8: Ironbow Ultra, Blue-Red Ultra, High-Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General Specifications | |
Color alarms (temperature alarms) | High temperature, low temperature, Isotherms |
Infrared spectral band | 7.5 µm to 14 µm |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) |
Relative humidity | 10% to 95%, non-condensing |
Spot temperature | Yes |
Safety standards | EN 61010-1: CAT none, pollution degree 2, EN 60825-1: Class 2, EN 60529, EN 62133 (lithium battery) |
Electromagnetic compatibility | EN 61326-1:2006, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
C Tick | IEC/EN 61326-1 |
US FCC | EN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3 |
Vibration and shock | 2G, IEC 68-2-6 and 25G, IEC 68-2-29 |
Drop | Engineered to withstand 2 m (6.5 ft) drop |
Size (H x W x L) | 26.7 x 10.1 x 14.5 cm (10.5 x 4.0 x 5.7 in) |
Weight (battery included) | Fixed focus .72 kg (1.6 lb), Manual focus .77 kg (1.7 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Warranty | Two-years (standard), extended warranties are available |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Application: | Fluke TiS60 Advanced Thermal Infrared Camera |
Industrial / Electrical Equipment, including, but not limited to: Motors, Pumps, Compressors, Bearings, Rollers, etc. | |
Electrical Service: Transformers, Fuse Panels, Control Centers, Circuit Breakers, Transmission lines, etc. | |
Process systems: tanks and vessels, reactors, refractory insulation, etc. | |
HVAC/R: Insulation, Air Handlers, Compressors, Moisture |