TSI Alnor EBT731 Balometer Capture Hood

TSI Alnor EBT731 Balometer Capture Hood

Model: EBT731
MFG Part: EBT731
 
Your Price:
$3,165.00

Availability: Quantity in stock

Free UPS Ground Shipping within Continental US
Note: This product normally leaves our warehouse within 1 to 2 business days.
Note: Some accessories and parts may have a longer lead time.
Valuetesters.com offers personal prices non-grumpy service.

Write a Review

Review(s)
Valuetesters.com offers financing and leasing options through Marlin Business Services Corp., a publicly trades company (NASDAQ: MRLN).

 

 

Quick Overview

TSI Alnor EBT731 Balometer Capture Hood is a multipurpose electronic air balancing instrument that is primarily used at diffusers and grilles to efficiently take direct air volume readings. It features a detachable micromanometer which can be used with optional probes in multiple measurement applications for increased flexibility. The TSI Alnore EBT731 comes with: 2 in. x 2 in. (610 mm x 610 mm) air capture hood/frame/base, manometer with carrying case, (4) AA size rechargeable NiMH batteries, multi-country AC adapter, 18 in. (46 cm) Pitot probe, (2) Static Pressure probes, 16 ft (4.8 m) Neoprene tubing, wheeled luggage-style carrying case, NIST traceable calibration certification, downloading software, USB interface cable, and manual.

 

Characteristics
Characteristics: TSI Alnor EBT731 Balometer Capture Hood
EBT731 comes with: 2 in. x 2 in. (610 mm x 610 mm) air capture hood/frame/base, manometer with carrying case, (4) AA size rechargeable NiMH batteries, multi-country AC adapter, 18 in. (46 cm) Pitot probe, (2) Static Pressure probes, 16 ft (4.8 m) Neoprene tubing, wheeled luggage-style carrying case, NIST traceable calibration certification, downloading software, USB interface cable, and manual
Capture Hood
  Ergonomic design and ultra light weight for easy, one-person operation
  Automatically senses and displays supply or return flows, saving time on the job
  Back pressure compensation ensures accurate readings
  Multiple hood sizes available for easy, cost effective use across multiple jobs
  Detachable digital micromanometer offers flexibility to use in multiple applications
Detachable Micromanometer
  Accurately measures pressure, velocity and flow to help you meet industry standards
  Auto-zeroing pressure sensor reduces user-steps and saves time
  Automatic density correction increases reading accuracy
  Intuitive menu structure allows for ease of use and setup
  Large graphic display with backlight offers easy-to-use interface
  Displays up to five measurements simultaneously
  On-screen messages and instructions
  Programmed for multiple languages
  Integrated Log-Tchebycheff duct traverse application simplifies calculations
  Bluetooth communications for transferring data or remote polling
  Compatible with AiRNAB™ digital documentation system
  Includes downloading software with USB cable
  Accommodates optional pitot, air flow (straight pitot), temperature/relative humidity, velocity matrix, or thermoanemometer probes for use in multiple applications
Description

TSI Alnor EBT731 Balometer Capture Hood is a multipurpose electronic air balancing instrument that is primarily used at diffusers and grilles to efficiently take direct air volume readings. It features a detachable micromanometer which can be used with optional probes in multiple measurement applications for increased flexibility. The lightweight, ergonomically designed EBT731 capture hood kit offers durable, trouble-free operation along with saving time and money by combining multiple measurement tools into one package.

The TSI Alnor EBT731 balometer capture hood helps the operator create a healthy and energy efficient environment while at the same time metting local codes, regulations, and guidelines for ventilation systems. The TSI Alnor EBT731 comes with: 2' x 2' (610 mm x 610 mm) air capture hood/frame/base, manometer with carrying case, (4) AA size rechargeable NiMH batteries, multi-country AC adapter, 18 in. (46 cm) Pitot probe, (2) Static Pressure probes, 16 ft (4.8 m) Neoprene tubing, wheeled luggage-style carrying case, NIST traceable calibration certification, downloading software, USB interface cable, and manual.

Specifications
Specifications: TSI Alnor EBT731 Balometer Capture Hood
Velocity Range
Pitot probes 25 to 15,500 ft/min (0.125 to 78 m/s)
Air flow probe 25 to 5,000 ft/min (0.125 to 25 m/s)
Velocity matrix 25 to 2,500 ft/min (0.125 to 12.5 m/s)
Accuracy ±3% of reading ±7 ft/min (±0.04 m/s) at velocities >50 ft/min (>0.25 m/s)
Units ft/min, m/s
Resolution 1 ft/min (0.01 m/s)
Pressure
Differential pressure ±15 in. H2O (±3735 Pa); 150 in. H2O (37.5 kPa), maximum safe operating pressure
Absolute pressure 15 to 40 in. Hg (356 to 1016 mm Hg)
Accuracy ±2% of reading ±0.0001 in. H2O (±0.025 Pa) static and differential; ±2% of reading absolute
Units in. H2O, in. Hg, Pa, hPa, kPa, mm Hg, cm Hg, mm H2O, cm H2O
Resolution 0.00001 in. H2O (0.001 Pa) static and differential; 0.01 in. Hg (1 mm Hg) absolute
Volume
Range 25 to 2,500 ft3/min (42 to 4250 m3/h) capture hood
Accuracy ±3% of reading ±7 ft3/min (±12 m3/h) at flows >50 ft3/min (>85 m3/h)
Units ft3/min, m3/h, m3/min, l/s
Resolution 1 ft3/min (1 m3/h)
RH
Range 5 to 95% RH temperature/RH probe
Accuracy ±3% RH
Resolution 0.1% RH
Temperature
Sensor in base 40 to 140°F (4.4 to 60°C)
Temperature/RH probe 14 to 140°F (-10 to 60°C)
Accuracy ±0.5°F (±0.3°C)
Units °F, °C
Resolution 0.1°F (0.1°C)
Operating Temperature Range 40 to 140°F (4.4 to 60°C)
Storage Temperature Range 40 to 140°F (4.4 to 60°C)
Statistics min, max, average
Data Storage 26,500 samples, time and date stamped
Logging Interval User selectable
Response Time 2 to 8 seconds, differential pressure sensor
Power Requirement Four AA-size cells or AC adapter
Applications
Applications: TSI Alnor EBT731 Balometer Capture Hood
  HVAC commissioning
  Clean room certification
  Troubleshooting HVAC systems
  Testing and balancing HVAC systems
Accessories
Specs and Videos