Viasensor G150-02N IAQ Indoor Air Quality Meter CO2

Viasensor G150-02N IAQ Indoor Air Quality Meter CO2

Model: G150-02N
MFG Part: 0
 
List Price:
$2,850.00
You Saved:
-178.12
Special Price:
$2,671.88

Availability: Quantity in stock

Free UPS Ground Shipping within Continental US
Note: This product normally leaves our warehouse within 1 to 2 business days.
Note: Some accessories and parts may have a longer lead time.

Write a Review

Review(s)

Quick Overview

Viasensor G150-02N IAQ Indoor Air Quality Meter CO2 with RH/T probe is designed to monitor CO2 for all indoor air quality applications. Made in UK.

 

Viasensor G150-02N IAQ Indoor Air Quality Meter CO2

More Views

  • Viasensor G150-02N IAQ Indoor Air Quality Meter CO2


iPhone App Valuetesters Valuetesters Professional Blog Valuetesters Youtube


Valuetesters.com offers financing and leasing options through Marlin Business Services Corp., a publicly trades company (NASDAQ: MRLN).


Characteristics
IAQ analyser package 0-20 percent CO2 with internal pump and G1.8 RH/T probe
Improved accuracy on CO2 readings
Quick verification of CO2 levels for site audits
Time saving with dual temperature probes
Data logging for long-term application
Easy to read large well-lit display
Built-in gas moisture removal
Includes:Battery charger, sample tube/filters and operating manual
Description
Viasensor G150-02N IAQ Indoor Air Quality Meter CO2 with RH/T probe is designed to monitor CO2 for all indoor air quality applications.

Viasensor G150-02N IAQ Indoor Air Quality Meter has been developed to incorporate the latest technology and specification requirerments, that provide the user with a fast, simple-to-use and accurate piece of environmental field kit. Made in UK.
Specifications
Gases MeasuredCO2: By custom dual wavelength infra-red with reference channel
RangeCO2: 0-20 percent
Measurement AccurancyCO2 Accuracy: plus/minus (1 percent range + 2 percent of reading) at reference conditions Temperature dependence: plus/minus 0.2 percent reading /C (typical at 5 percent CO2) Pressure dependence: plus/minus 0.02 percent of reading / hPa (typical at 5 percent CO2)
Response time T90CO2: ≤ 20 seconds ≤ 60 seconds
Visual and audible alarmUser selectable CO2 and O2 alarm levels
CommunicationsUSB type B mini-connector, HID device class
Data Storage1000 reading sets + 270 events
Operating temperature41 F to 104 F; 5 C to 40 C
Relative humidity0 - 95 percent non condensing (RH Probe 0 - 100 percent non condensing
Barometric pressureplus/minus 500mbar from calibration pressure
Dimensions6½ x 4 x 2 3/16 inches; 165 x 100 x 55mm
Weight18 oz.; 495 grams
RH measurementRH Probe 0 - 100 percent RH non condensing
RH accuracyplus/minus 1.5 percent RH across the range
Temperaturex2 using optional probes 32 F to 122 F; 0 C to 50 C
Temperature accuracy, typicalplus/minus 0.2 C from 32 to 44 C, plus/minus 0.5 C over the rest of the rang
Barometric pressure800 - 1200 mbar
Applications
General IAQ
Environmental Site Audits
Laboratories
Medical
Accessories
Specs and Videos

Technical Specs for Viasensor G150-02N IAQ Indoor Air Quality Meter CO2:

View FileViasensor-G150-02N    Size: (641.07 KB) Viasensor-G150-02N

You may also be interested in the following product(s)