AEMC L322 4 to 20mA Logger is a two channel 4-20mADC current data logger. This thermocouple logger is able to perform a variety of recording tasks with easy and intuitive setup from a computer using DataView?« software.
- AEMC L322 Thermocouple Datalogger for 4 to 20mA
- Two independent input channels
- Measures current up to 25mADC with 0.1mA resolution
- Storage rates are programmable to 8 per second or 1 per day
- 3 storage modes selectable by user; Stop when full, FIFO; XRM
- Up to 240,000 measurements stored in non-volatile memory
- Two standard AA, alkaline batteries provide power
- Lightweight and compact enough to fit anywhere
- Logger status quickly and clearly displayed via 5 LED indicators
- Safety rating of 50V CAT III
- Comes complete with FREE DataView software for data storage, real-time waveform display, analysis and report generation
Specifications: | AEMC L322 4 to 20mA Thermocouple Logger |
Electrical: | |
Channels | Two |
Input Connection | Detachable terminal strip |
Measurement Range | 0 to 25mAdc |
Resolution | 0.1mA |
Accuracy | 0 to 1mA: unspecified 1mA to 30mA: ±(0.25% of Reading + 100μA) |
Sample Rate | 8 samples taken at storage interval |
Storage Rate | Programmable from 125ms to 1 day |
Storage Modes | Start/Stop, FIFO and Extended Recording Mode (XRM™) |
Recording Length | 15 minutes to 8 weeks, programmable using DataView® |
Memory | 240,000 measurements (512KB) - The recorded data is stored in non-volatile memory and will be retained even if the battery is low or removed. |
Communication | USB 2.0 optically isolated |
Power Source | 2 x 1.5V AA-cell alkaline batteries |
Battery Life | 100 hours to >45 days (dependent on sample rate and recording length) |
Mechanical: | |
Dimensions | 4.94 x 2.75 x 1.28" (125 x 70 x 32mm) |
Weight (with battery) | 7 oz (200 grams) |
Case | UL94-V0 |
Vibration | IEC 68-2-6 (1.5mm, 10 to 55Hz) |
Shock | IEC 68-2-27 (30G) |
Drop | IEC 68-2-32 (1m) |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: | AEMC L322 4 to 20mA Thermocouple Logger |
Process control monitoring and troubleshooting | |
Sensor monitoring | |
General DC current monitoring | |
Profile temperature, pressure, flow and other parameters directly |
Related Items
FIND REPLACEMENT
Replaced by 6528 and 6529
FIND REPLACEMENT
Replaced by Cat #2151.36