Alnor AXD610 Micromanometer measures differential and static pressure. This micromanometer calculates velocity when used with a pitot tube.
Product made in USA and comes with NIST Certificate of Calibration.
- Measure differential and static pressure from -15 to +15 in. H2O (-3735 to +3735 Pa)
- Calculate and display velocity when using a Pitot tube
- Accurate and reliable pressure measurement
- Hard carrying case, 4 alkaline batteries, operation and service manual and NIST calibration certificate
Specifications: | Alnor AXD610 Digital Handheld Micromanometer |
Static/Differential Pressure | |
Range | -15 to +15 in. H2O (-28.0 to +28.0 mm Hg, -3735 to +3735 Pa) |
Accuracy | ±1% of reading ±0.005 in. H2O (±1 Pa, ±0.01 mm Hg) |
Resolution | 0.001 in. H2O (0.1 Pa, 0.01 mm Hg) |
Velocity From a Pitot Tube | |
Range | 250 to 15,500 ft/min (1.27 to 78.7 m/s) |
Accuracy | ±1.5% at 2,000 ft/min (10.16 m/s) |
Resolution | 1 ft/min (0.1 m/s) |
Instrument Temperature Range | |
Operating | 40 to 113°F (5 to 45°C) |
Storage | -4 to 140°F (-20 to 60°C) |
General | |
Dimensions | 3.3 in x 7.0 in x 1.8 in (8.4 cm x 17.8 cm x 4.4 cm) |
Weight | 0.6 lbs. (0.27 kg) |
Power Requirements | Four AA-size batteries |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: | Alnor AXD610 Digital Handheld Micromanometer |
Works well in HVAC troubleshooting, balancing and testing HVAC commissioning and troubleshooting Static pressure measurements Differential pressure measurements | |
Duct traverses with Pitot Tube |
Working in ducts
Good for taking pressure readings in ducts to make sure the proper balancing is taken care of. Happy with it for sure.
Did you find this helpful?
8 of 9 Found Helpful
Reviewed by: (Verified Buyer) Walter from Canada.
on 5/2/2018
5
useful
used in our laboratory. very accurate.
Did you find this helpful?
8 of 9 Found Helpful
Reviewed by: (Verified Buyer) labrat from US.
on 1/5/2018
5
Intro Unit that performs
If you need to check static pressure and take some velocity measurements via a pitot tube, this gets it done.
Did you find this helpful?
7 of 8 Found Helpful
Reviewed by: (Verified Buyer) AirGuyLarry from .
on 4/4/2018
5
works
handy little tool there. Makes my balance work easy eh.
Did you find this helpful?
5 of 7 Found Helpful
Reviewed by: (Verified Buyer) AtoZed from US.
on 6/16/2018
5
Related Items
(0)
Coming Soon
Free Shipping.
(0)
Coming Soon
Free Shipping.
(0)
Coming Soon
Free Shipping.