Amprobe 33XR-A Digital Multimeter has manual ranging with temperature and capacitance. Amprobe 33XR-A Digital Multimeter gives the contractor and field service technician all the essential measurement functions they need in a rugged package.
Characteristics: | Amprobe 33XR-A Digital Multimeter |
Frequency to 40 MHz, temperature to 1832 Degrees F, capacitance to 4000 μF | |
Input warning tone when test leads are in wrong jack | |
1000 V/750 V dc/ac | |
10 Amps ac/dc, fully safety fused | |
DC microamps for low current levels | |
Resistance to 4 M?äª | |
Continuity beeper | |
Min/Max, Relative, Peak and Data Hold | |
Auto power off to save battery life | |
Separate door for easy battery and fuse access | |
Magne-Grip Holster with magnetic hanging strap | |
CAT III 600 V, CAT II 1000 V rated | |
UL (CULUS) listed | |
Warranty (years): | 1 |
Specifications: | Amprobe 33XR-A Digital Multimeter |
Voltage AC | 750 V Avg. |
Voltage DC | 1000 V |
mV AC | Average |
Basic DC Accuracy | 0.7% |
DC Current, fused | 10 A |
AC Current, fused | 10 A |
Resistance | 4M? |
Capacitance | 4000μF |
Frequency | 40 MHz |
Temperature | 1832 Degrees F/1000 Degrees C |
DC Voltage | Ranges 400 mV, 4 V, 40 V, 400 V, 1000 V Accuracy all ranges +/- (0.7 % rdg + 1 dgt) Resolution 100 μV Input Impedance 10 MΩ |
AC Voltage (45 Hz to 500 Hz) | Ranges 400 mV, 4 V, 40 V, 400 V, 750 V Accuracy 4 V Range, 200 Hz to 500 Hz +/- (2.0 % rdg + 4 dgts) Accuracy All other ranges +/- (1.5 % rdg + 4 dgts) Resolution 100 μV Input Impedance 10 MΩ |
DC Current | Ranges 400 μA, 4 mA, 40 mA, 300 mA, 10 A Accuracy 400 μA to 300 mA ranges +/- (1.0 % rdg + 1 dgt) Accuracy 10A range +/- (2.0 % rdg + 3 dgts) Resolution 0.1 μA Voltage Burden 400 μA range 1 mV/μA Voltage Burden 4 mA range 100 mV/1 mA Voltage Burden 40 mA range 12 mV/1 mA Voltage Burden 300 mA range 4 mV/1 mA Voltage Burden 10 A range 100 mV/1 A |
AC Current (45 Hz to 500 Hz) | Ranges 400 μA, 4 mA, 40 mA, 300 mA, 10 A Accuracy 400 μA to 300 mA ranges +/- (1.5 % rdg + 4 dgts) Accuracy 10 A range +/- (2.5 % rdg + 4 dgts) Resolution 0.1 μA Voltage Burden See DC Current |
Resistance | Ranges 400 Ω, 40 kΩ, 4 MΩ Accuracy 400 Ω and 40 kΩ ranges +/- (1.0 % rdg + 4 dgts) Accuracy 4 MΩ range +/- (1.2 % rdg + 4 dgts) Resolution 100 mΩ Open Circuit Voltage 400 Ω range 3.0 V dc Open Circuit Voltage All other ranges 0.5 V dc typical |
Capacitance | Ranges 4 μF, 40 μF, 400 μF, 4000 μF Accuracy 4 μF range +/- (5.0 % rdg + 10 dgts) Accuracy 40 μF, 400 μF ranges +/- (5.0 % rdg + 5 dgts) Accuracy 4000 μF range +/- (5.0 % rdg + 15 dgts) Resolution 0.1 μF Test Voltage < 3.0 V Test Frequency 10 Hz Input Protection μA/mA input 0.315 A/1000 V fast blow ceramic fuse 6.3 x 32 mm |
Temperature | Ranges -20 to 1000 Degrees C, -4 F to 1832 Degrees F Accuracy -20 to 10 Degrees C +/- (2.0 % rdg + 4 Degrees C ) Accuracy 10 to 200 Degrees C +/- (1.0 % rdg + 3 Degrees C ) Accuracy 200 to 1000 Degrees C +/- (3.0 % rdg + 2 Degrees C ) Accuracy -4 to 50 Degrees F +/- (2.0 % rdg + 8 Degrees F) Accuracy 50 to 400 Degrees F +/- (1.0 % rdg + 6 Degrees F) Accuracy 400 to 1832 Degrees F +/- (3.0 % rdg + 4 Degrees F) Resolution 1 Degree C, 1 Degree F |
Frequency (autoranging) | Ranges 4 kHz, 40 kHz, 400 kHz, 4 MHz, 40 MHz Accuracy all ranges +/- (0.1 % rdg + 3 dgts) Resolution 1 Hz Sensitivity 10 Hz to 4 MHz > 1.5 V ac rms Sensivity 4 MHz to 40 MHz > 2 V ac rms, < 5 V ac rms Min Pulse Width > 25 ns Duty Cycle Limits > 30 % and < 70 % |
Continuity | Audible Indication < 35 ? Response Time 100 ms |
Diode Test | Test Current 1.0 mA (approximate) Accuracy +/- (1.5 % rdg + 3 dgts) Resolution 1 mV Open Circuit Volts 3.0 V dc typical |
Peak Hold | AC Volts Accuracy 40 V to 750 V +/- (3.0 % rdg + 60 dgts) AC Current Accuracy +/- (3.0 % rdg + 60 dgts) Response Time > 1 ms |
Overload Protection | AC/DC Voltage 400 mV range 1000 V dc or 750 V ac rms 15 sec AC/DC Voltage All other ranges 1000 V dc or 750 V ac rms AC/DC Current uA/mA input 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) AC/DC Current 10A input 10 A /1000 V fast-blow ceramic (10 x 38 mm)(10 A for 4 minutes maximum followed by a 12 minute cooling period) Resistance 1000 V dc or 750 V ac rms Continuity 1000 V dc or 750 V ac rms Diode Test 1000 V dc or 750 V ac rms Capacitance 0.315 A /1000 V fast-blow ceramic (6.3 x 32 mm) Temperature 1000 V dc or 750 V ac rms Frequency 1000 V dc or 750 V ac rms |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.