Amprobe AC50A measures up to 60 A ac, ac voltage, resistance and continuity. The AC50A is CAT II 600 V rated and UL listed. It ships with a users manual, heavy-duty test leads and carrying case.
- AC current measurement to 60 A
- Leakage current measurements with resolution of 0.01 mA
- AC voltage to 400 V
- Resistance measurement and continuity beeper
- Min/Max control to see largest and smallest values in a series of measurements
- Relative value measurement to determine differentials
- Data Hold to freeze measurement value on the display
- Digital display with analog bargraph
- Jaw opening 30 mm (1.2 inch)
- Auto-Power-Off to save battery life
Specifications: | Amprobe AC50A Clamp Multimeter |
Current ac | 40 mA, 400 mA, 4 A, 40 A, 60 A 0 - 40 mA (10 μA resolution) +/-(1.5 % rdg. +3 dgt) 40 - 400 mA +/-(1.5 % rdg. +3 dgt) 400 mA - 4 A +/-(1.5 % rdg. +3 dgt) 4 - 40 A +/-(1.5 % rdg. +3 dgt) 40 - 50 A +/-(1.5 % rdg. +5 dgt) 50 - 60 A +/-(3.0 % rdg. +5 dgt) |
Voltage ac | 0 to 400 V +/-(1.0 % rdg. +3 dgt) Overload Protection 600 VAC |
Resistance | 0 to 400 ohms +/-(1.0 % rdg. +3 dgt) Overload Protection 600 VAC |
Continuity | < 40 ohms approx Open Circuit Voltage < 0.4 V Overload Protection 600 V AC |
Range Selection | Manual |
Bar graph | 40 segments |
Measuring Rate | 20 measurements/sec. (bargraph) 2 measurements/sec. (LCD) |
Clamp Opening | 30 mm |
Power Supply | Battery 1.5 V IEC LR6 (alkaline), 2 each |
Current Consumption | Approx. 10 mA |
Humidity | < 75 % relative humidity |
Display | 3-3/4, LCD including functions and symbols, 4000 count |
Auto-Power-Off | Approx. 30 min. |
Overload Display | Overload Display |
Overvoltage category | CAT II 600 V |
Pollution Degree | 2 |
Battery Display | Battery symbol in display at low battery |
Operating Temperature | -10 C to 50 Degrees C |
Storage Temperature | 20 C to 60 Degrees C with battery removed |
Dimensions | 183 x 63.6 x 35.6 mm |
Weight | 190 g |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Extremely useful and easy to use
We have used this meter at multiple installations for field bus distributed I/O. The meter helped to determine leakage current and the source, which could cause communication problems and nuisance tripping. The meter is very useful in trouble shooting problems at new installations and existing issues, out in the field.
Did you find this helpful?
9 of 10 Found Helpful
Reviewed by: (Verified Buyer) Mark59 from US.
on 5/4/2018
5
Related Items
(0)
Coming Soon
Free Shipping.
(0)
In Stock
Free Shipping.