Amprobe AM-570 TRMS Multimeter for Industrial Applications is engineered for electricians working in commercial environments with advanced or large electrical systems. Amprobe AM-570 features True RMS measurements, dual thermocouples for temperature differentials, and the ability to detect stray voltage.
- Amprobe AM-560 Advanced Multimeter for HVAC
- Measures AC/DC voltage, ac/dc current, resistance,
frequency, capacitance, temperature, and duty cycle. - Low-Z for stray voltages
- Dual thermocouple ports allow for measurement of temperature differential
- Test variable frequency drives with low pass filter
- Voltect non-contact voltage tester
- Continuity testing has audible indicator
- Diode Test
- Backlit LCD with analog bar graph display
- Data hold function
- Memory recall for min/max values
- Peak hold
- Relative zero mode
- Work light and test lead storage are built-in
- Gives warning if leads are improperly connected
- Manual and auto ranging
- Safety rated to CAT IV 600V, CAT III 1000V
Specifications: | Amprobe AM-570 TRMS Multimeter for Industrial Applications | |
Range | Best Accuracy | |
True-RMS | Yes | |
AC Voltage | 6.000 / 60.00 / 600.0 / 1000 V | ±(1.0% Rdg + 3 LSD) @ 45 Hz to 400 Hz, 0 V to 600 V |
DC Voltage | 600.0 mV 6.000 / 60.00 / 600.0 / 1000 V | ±(0.5% Rdg + 2 LSD) @ 6 V to 600 V ranges |
Resistance | 600.0 Ohms 6.000 / 60.00 / 600.0 kOhms 6.000 / 60.00 MOhms | ±(1.0% Rdg + 2 LSD) @ 6 kOhms to 600 kOhms ranges |
AC Current | 600.0 μA / 6000 μA 60.00 mA / 500.0 mA / 10.00 A | ±(2.0% Rdg + 5 LSD) @ 45 Hz to 400 Hz |
DC Current | 600.0 μA / 6000 μA 60.00 mA / 500.0 mA / 10.00 A | ±(1.5% Rdg + 3 LSD) |
Frequency | 60.00 / 600.0 Hz 6.000 / 60.00 / 600.0 kHz 6.000 / 60.00 MHz | ±(0.1% Rdg + 3 LSD) |
Duty cycle | 10.00% to 90.00% | ±(1.2% Rdg + 30 LSD) @ 5Hz to 2 kHz |
Capacitance | 60.00 / 600.0 nF 6.000 / 60.00 / 600.0 / 6000 µF 60.00 mF | ±(3.0% Rdg + 5 LSD) @ 600 nF to 60 µF ranges |
Temperature | -40 °F to 1832 °F / -40 °C to 1000 °C | °F: ±(1.0% rdg + 12) @ >104 °F to 752 °F / °C: ±(1.0% rdg + 8) @ >40 °C to 400 °C |
Number of temperature inputs | Dual Thermocouple |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Related Items
(1)
Coming Soon
(0)
Coming Soon
Free Shipping.
(0)
Coming Soon
(0)
FIND REPLACEMENT
Replaced by DM66