Amprobe AMP-330 TRMS Clamp Meter for Motor Maintenance and HVAC Applications is a complete clamp meter for the modern technician with TRMS measurements and 1000 V AC/DC and 600 A AC/DC range, along with Low-Pass Filter, worklight, and Amp-Tip technology for readings down to the tenth of an Amp. The Amprobe AMP-330 is designed to take 3-Phase Motor measurements including Rotation and Inrush, and also features a backlit screen, NCV detection and accurately measures Temperature, Frequency, Resistance, and Capacitance, and performs Diode Test.
Characteristics: | Amprobe AMP-330 TRMS Clamp Meter for Motor Maintenance |
Reads AC/DC Current to 600 A and AC/DC Voltage to 600 V | |
-40° to 752°F, (-40° to 400°C) Temperature readings |
|
DC Microamps output for gas appliance testing | |
3-phase sequence and motor rotation testing |
|
Inrush current monitoring during motor start-up | |
Highly accurate TRMS readings | |
Precise low-amp 0 to 60 A readings with AmpTip technology | |
Low pass filter for measuring variable frequnecy drives | |
Continuity beeper, diode test and capacitance readings | |
Quick analysis with Data Hold and Relative Zero | |
Low battery indicator and Auto Power off | |
Jaw works with conductors up to 2.0 inches (51mm) | |
CAT IV 600 V, CAT III 1000 V safety rated | |
Amprobe AMP-330 includes: | Test leads, batteries (installed), alligator clip set, banana plug K-type thermocouple, carrying case, and user manual |
Specifications: | Amprobe AMP-330 TRMS Clamp Meter for Motor Maintenance |
Safety Rating | CAT IV 600 V, CAT III 1000 V |
Jaw Opening | 2.0 in (51 mm) |
AC Voltage (True-RMS) | Range: 0 to 1000 V Accuracy: ±0.8% + 5LSD (50 to 60 Hz) ±1.5% + 5LSD (20 to 200 Hz) ±10% + 5LSD (200 to 400 Hz) |
DC Voltage | Range: 0 to 1000 V Accuracy: ±0.8% + 5LSD |
AC+DC Voltage | Range: 0 to 1000 V Accuracy: ±1.0% + 7LSD (50 to 60 Hz) ±1.8% + 7LSD (DC, 40 to 200 Hz) ±12% + 7LSD (200 to 400 Hz) |
AC Current (True-RMS) | Range: 0 to 1000 A Accuracy: ±1.8% + 5LSD (40 to 100 Hz) ±2.2% + 5LSD (100 to 400 Hz) |
DC Current | Range: 0 to 1000 A Accuracy: ±1.8% + 5LSD |
AC+DC Current | Range: 0 to 1000 A Accuracy: ±2.2% + 7LSD (DC, 40 to 100 Hz) ±2.5% + 7LSD (100 to 400 Hz) |
Precise Low Current AC | Range: 0 to 60.00 A Accuracy: ±1.5% + 5LSD (0.00 to 20.00 A, 40 to 100 Hz) ±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) ±3.0% + 5LSD (20.00 to 60.00 A, 40 to 100 Hz) ±3.0% + 5LSD (20.00 to 60.00 A, 100 to 400 Hz) |
Precise Low Current DC | Range: 0 to 60.00 A Accuracy: ±1.5% + 5LSD (0.00 to 20.00 A) ±3.0% + 5LSD (20.00 to 60.00 A) |
Precise Low Current AC+DC | Range: 0 to 60.00 A Accuracy: ±2.0% + 7LSD (0.00 to 20.00 A, DC, 40 to 100 Hz) ±2.2% + 7LSD (0.00 to 20.00 A, 100 to 400 Hz) ±3.0% + 7LSD (20.00 to 60.00 A, DC, 40 to 100 Hz) ±3.0% + 7LSD (20.00 to 60.00 A, 100 to 400 Hz) |
Frequency | Range: 5.00 to 999.9 Hz Accuracy: ±1.0% + 5LSD (1000 V range) Range: 40.0 to 400.0 Hz Accuracy: ±1.0% + 5LSD (1000 A range) |
Resistance | Range: 0.0 to 60.00 kΩ Accuracy: ±1.0% + 5LSD |
Capacitance | Range: 0.0 to 2500 μF Accuracy: ±2.0% + 4LSD |
Continuity Beeper | ON ≤ 10 Ω OFF > 250 Ω |
Non-Contact Voltage | 20 to 440 V, 50/60 Hz |
DC Microamps | Range: 0.0 to 2000 μA Accuracy: ±1.0% + 5LSD |
Temperature (Type K thermocouple) | Range: -40.0 to 752°F, -40.0 to 400°C Accuracy: -40.0 to 14.0°F (±1.0% +3.0°F), >14.0 to 99.9°F (±1.0% +1.5°F) 100 to 752°F (±1.0% +2°F), -40.0 to -10.0°C (±1.0% +1.5°C) >-10.0 to 99.9°C (±1.0% +0.8°C), 100 to 400°C (±1.0% + 1°C) |
3-Phase and Motor Rotation Indication | Rotation-R for mains supply Rotation-M for motors |
Inrush Current | • |
Peak Hold (Crest) | • |
Work Light | • |
True-RMS | • |
Low Pass Filter | • |
Autoranging | • |
Relative Zero | • |
MAX/MIN/AVG | • |
Diode Test | • |
Data Hold | • |
Backlight | • |
Auto Power Off | • |
Display | 3-5/6 digits 6000 counts |
Polarity | Automatic |
Update Rate | 5 per second nominal |
Operating Temperature | 14 to 122°F (-10 to 50°C) |
Relative Humidity | Non condensing at ≤10°C 90% at 10 to30°C 75% at 30 to 40°C 45% at 40 to 50°C |
Operating Altitude | 0 to 2000 m |
Pollution Degree | 2 |
Storage Temperature | -4 to 140°F (-20°C to 60°C), < 80% RH |
Temperature Coefficient | Nominal 0.10 x (specified accuracy)/ °C @ (0°C to 18°C or 28°C to 50°C) |
Battery | Two AA 1.5 V battery |
EMC | Meets EN 61326-1:2006 |
Safety Compliance | UL/IEC/EN 61010-1 ed. 3.0, IEC/EN 61010-2-033 ed. 1.0, CAN/CSA C22.2 NO. 61010-1 ed. 3.0, IEC/EN 61010-2-032 ed. 3.0 & IEC/EN 61010-031 ed. 1.1 |
Certification | UL (c/us) and CE |
Dimensions (L x W x H) | 10.16 x 3.70 x 1.73 in (258 x 94 x 44 mm) |
Weight | 420 g (0.93 lb) |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: | Amprobe AMP-330 TRMS Clamp Meter for Motor Maintenance |
Motor Maintenance | |
HVAC applications | |
Repairs | |
Troubleshooting | |
DIY applications |
Related Items
(0)
Coming Soon
Free Shipping.
(0)
In Stock
(0)
In Stock