Bacharach HGM-MZ Multi Zone Halogen Gas Monitor 3015-5045 is designed for continuous multi-point monitoring of CFC, HFC, HCFC, and Halon refrigerant gases. This multi zone Halogen gas monitor identifies current and peak gas levels.
- 2 years from date of shipment
- Expand 4 to 16 zones
- Remote display accessory available that will support 8 MZs (64 zones)
- Monitors up to 1,200 feet
- Capable of detecting 35 refrigerant gases
- Identifies current and peak gas levels
- Uses infrared technology
Specifications: | Bacharach HGM-MZ Multi Zone Halogen Gas Monitor 3015-5045 |
Dimensions | 12.23 x 13.7 x 4.96 inches |
Certification | UL 61010-1, CAN/CSA 22.2 No. 61010 & CE Mark |
AC Power | 120 to 240 VAC, 50/60 Hz, 20 W |
Ambient Humidity | 5 percent to 90 percent RH (non-condensing) |
Operating Temperature | 32 to 122 F (0 to 50 C) |
Power Safety Mode | Fully automatic system reset. All programmed parameters retained. |
Communications | Full two-way communication with HGM-RD Display Module or Building Management System via RS-485 serial interface. RS-232C communication port standard |
Alarms | Four SPDT alarm contacts are provided (rated 3A 250VAC) Three assigned to PPM level alarms, one assigned to system faults |
Conditioned Signal | Dual optional 4-20mAdc isolated outputs. Channel 1 = zone area, Channel 2 = PPM |
Response Time | 5 to 120 seconds depending on air line length and number of zones |
Re-Zero | Auto or on zone change |
Sampling Mode | Automatic or manual (hold) |
Temperature Drift | plus/minus 0.3 percent of reading per degrees C |
Front Panel | 3 Indicator lights: Green - Monitor is powered on. LED glows during normal operation; flashes when unit is in warm-up mode Red - Alarm. LED flashes when any point has exceeded the alarm setting. Yellow - Fault. LED flashes when there is a system fault |
Measuring Range | All gasses 0 to 10,000 ppm |
Accuracy | plus/minus 1ppm plus/minus 10 percent of reading from 0-1000ppm (R11 plus/minus 10ppm plus/minus 15 percent of reading 0-1000ppm) |
Sensitivity | All gasses 1 ppm (R11 plus/minus 10ppm plus/minus 15 percent of reading 0-1000ppm) |
Gas Library | CFC: R-11, R-12, R-113, R-114, R-502 HFC: R-404a (HP62), R-407a, R-407c (AC9000), R-134a, R-410a (AZ20), R-507 (AZ50), R-508b (SUVA95), R236FA, R125 HCFC: R-22, R-123, R-124, R-500, R-503, R-401a (MP39), R-402a (HP80), R-402b (HP81), R-408a, R-409a, R-23, R21 HALON: H1301,H2402, H1211 OTHER: FA188, FC72, N1230 |
Detector Type | Infrared Non-Dispersive |
Coverage | 12 point standard, expandable to 16 points in 4 point increments |
Weight | 15 lbs. |
Altitude Limit | 6,562 ft (2,000 m) |
Monitoring Distance | 1,200 ft. maximum for combined length of sample + exhaust tubing (each zone) |
System Noise | Less than 40dB(A) @ 10 feet |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: | Bacharach HGM-MZ Multi Zone Halogen Gas Monitor 3015-5045 |
Walk-in freezers | |
Refrigeration racks | |
Chillers | |
Physical plants | |
Grocery stores | |
Mechanical rooms |