- Fieldpiece LT17A Digital Multimeter with Temperature
- Works with Fieldpiece Accessory Heads
- Continuity Indicator
- Silicone Leads with Detachable Probe Tips
- Tilt Stand and Magnetic Hanger
- Bright Blue Backlight
- MAX/MIN hold
- Rugged ABS case with rubber boot
- Auto power-off (APO) to conserve battery life
- Comfortable handheld design
Specifications | Fieldpiece LT17A Digital Multimeter with Temperature | |
DC Voltage | Ranges | 200mV, 2000mV, 20V, 200V, 600V |
Resolution | 0.1mV | |
Accuracy | 0.5%±1 | |
Input Impedence | 10MO | |
AC Voltage (50Hz-500Hz) | Ranges | 200mV, 2000mV, 20V, 200V, 600V |
Resolution | 0.1mV | |
Accuracy | 1.2%±4(200mV to 20V ranges), 2%±4(200V and 600V ranges) | |
Input Impedence | 10MO | |
DC Current (through meter) | Ranges | 200µA, 20mA, 200mA |
Resolution | 0.1µA | |
Accuracy | 1.0%±1 | |
Voltage burden | 800mV | |
AC Current (through meter) | Ranges | 200µA, 20mA, 200mA |
Resoltuion | 0.1µA | |
Accuracy | 1.5%±4 | |
Voltage burden | 800mV | |
Frequency (autoranging) | Range | 10Hz to 40KHz |
Resoltuion | 1Hz | |
Sensitivity | 3.5V rms min | |
Accuracy | 0.1%± 3 | |
Resistance (ohms) | Ranges | 200O, 2kO, 200kO, 20MO |
Resolution | 0.1O | |
Accuracy | 1.0%±4 (200O to 200kO ranges), 2.0%±4 (20MO range) | |
Open circuit voltage | 0.3VDC typical, (3.0VDC on 200O) | |
Diode Test | Accuracy | 1.5%±3 |
Test current | 1.0mA approx. | |
Open circuit voltage | 3.0VDC typical | |
Capacitance (MFD) | Ranges | 200µF, 2kµF, 20kµF |
Resolution | 0.1µF | |
Accuracy | 4%±10 | |
Test frequency | 21Hz | |
Test voltage | <3.0V | |
Temperature | Ranges | -30 to 1400°F (-34 to 750°C) |
Resolution | 0.1°F/°C | |
Accuracy | ±1°F; 32 to 120°F (±0.5°C; 0 to 48°C), ±1.0%+1.5°F; -4 to 750°F (±1.0%+1.0°C; -20 to 399°C) ±3.0%+4°F; -30 to -4°F and 750 to 1400°F (±3.0%+2°C; -34 to -20°C and 399 to 750°C) | |
Sensor type | K-type thermocouple | |
Field Calibration (temp offset pot) | The LT17A can be easily calibrated on the job. Use a bucket of ice water to have a known 32°F (0°C) temperature. With the thermocouple in the ice water, adjust the TEMP OFFSET pot on the face of the meter until it reads 32.0 (0.0) | |
Fuse Replacement | When only certain ranges quit working, check the fuse. Open the case and replace according to the Overload Protection values below. If that doesn’t work visit our Warranty Page.to check for other problems. | |
Overload Protection | VAC/DC | (200mV range ) 600VAC/DC rms for 15 sec (>200mV range) 600VAC/DC rms |
AAC/DC | 0.25A/500V fuse (6.3X32mm) | |
Capacitance | 0.25A/500V fuse (6.3X32mm) model RFM66 | |
Temperature | 30VAC/DC rms | |
Frequency | 500VAC/DC rms | |
Resistance | 500VAC/DC rms | |
Diode Test | 500VAC/DC rms | |
Continuity | 500VAC/DC rms | |
Auto-off | off after 25 minutes to extend battery | |
Indicators | Continuity beeper (<100O). Low bat | |
Overrange | "OL" or “-OL” is displayed | |
Operating environment | 32 to 122°F (0 to 50°C) <70%RH | |
Storage environment (with batteries removed) | -4 to 140°F (-20 to 60°C) <80%RH | |
Altitude | 6561.7 feet (2000m) | |
Battery life | 150 hours typical | |
Battery type | 9V NEDA 1604 type | |
Stated accuracies | 74°F±8°F (23°C±4°C), 75%RH | |
Temperature coefficient | 0.1 x (specified accuracy) 1°F/°C (32 to 66°F (0 to 19°C), 82 to 122°F (28 to 50°C)) | |
What's Included? | Classic Style Clamp Meter with Temperature (LT17A), Deluxe Silicone Test Leads (ADLS2), 400A Amp Clamp Accessory (ACH4), Wrap Tab Bead Tip Thermocouple (ATB1), Short Alligator Lead Extensions (ASA2), Mail Pouch-Style Instrument Case (ANC5), 9-Volt battery (installed), Operator’s manual |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.