The Fluke 1555 10kV Professional Insulation Resistance Tester provides digital insulation testing up to 10kV, making it perfect for testing a broad range of high voltage equipment including cables, switchgear, motors, and generators.
- Fluke 1555 10kV Professional Insulation Resistance Tester
250V Test Voltage (dc) | Range: < 200 kO - Accuracy: unspecified Range: 200 kO to 5 GO - Accuracy: 5% Range: 5 GO to 50 GO - Accuracy: 20% Range: > 50 GO - Accuracy: unspecified |
500 V Test voltage (dc) | Range: < 200 kO - Accuracy: unspecified Range: 200 kO to 10 GO - Accuracy: 5% Range: 10 GO to 100 GO - Accuracy: 20% Range: > 100 GO - Accuracy: unspecified |
1000 V Test voltage (dc) | Range: < 200 kO - Accuracy: unspecified Range: 200 kO to 20 GO - Accuracy: 5% Range: 20 GO to 200 GO - Accuracy: 20% Range: > 200 GO - Accuracy: unspecified |
2500 V Test voltage (dc) | Range: < 200 kO - Accuracy: unspecified Range: 200 kO to 50 GO - Accuracy: 5% Range: 50 GO to 500 GO - Accuracy: 20% Range: > 500 GO - Accuracy: unspecified |
5000 V Test voltage (dc) | Range: < 200 kO - Accuracy: unspecified Range: 200 kO to 100 GO - Accuracy: 5% Range: 100 GO to 1 TO - Accuracy: 20% Range: > 1 TO - Accuracy: unspecified |
10000 V Test voltage (dc) | Range: < 200 kO - Accuracy: unspecified Range: 200 kO to 200 GO - Accuracy: 5% Range: 10 GO to 2 TO - Accuracy: 20% Range: > 2 TO - Accuracy: unspecified |
Bar graph range | 0 to 1 TO |
Insulation test voltage accuracy | -0 percent, +10 percent at 1 mA load current |
Induced ac mains current rejection | 2 mA maximum |
Charging rate for capacitive load | 5 seconds per µF |
Discharge rate for capacitive load | 1.5 s/µF |
Leakage current measurement | Range: 1 nA to 2 mA Accuracy: plus/minus (5 percent + 2 nA) |
Capacitance measurement | Range: 0.01 uF to 15.00 µF Accuracy: plus/minus (15 percent rdg + 0.03 µF) |
Timer | Range: 0 to 99 minutes Resolution: Setting: 1 minute Indication: 1 second |
Live circuit warning | Warning range: 30 V to 660 V ac/dc, 50/60 Hz Voltage accuracy: plus/minus (15 percent + 2 V) |
Display | 75 mm x 105 mm |
Power | 12 V lead-acid rechargeable battery, Yuasa NP2.8-12 |
Charger Input (AC) | 85 V ac 50/60 Hz 20 VA |
Temperature (operating) | -20 ºC to 50 ºC (-4 ºF to 122 ºF) |
Temperature (storage) | -20 ºC to 65 ºC (-4 ºF to 149 ºF) |
Humidity | 80 percent to 31 ºC decreasing linearly to 50 percent at 50 ºC |
Altitude | 2000 m |
Enclosure sealing | IP40 |
Input overload protection | 1000 V ac |
Electromagnetic compatibility | EN 61326 |
Safety compliance | CAT III 1000 V, CAT IV 600 V |
Polution degree | 2 |
Dimensions | 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13 in) |
Weight | 3.6 kg (7.94 lb) |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Related Items
(0)
Coming Soon
Free Shipping.
(0)
Coming Soon
Free Shipping.