The Fluke 1625 Geo Earth Ground Resistance Meter executes all four types of earth ground measurement tests. Capable of measuring earth ground loop resistances solely with clamps.
- Fluke 1625 Geo Earth Ground Resistance Meter
- Automatically chooses the best measuring frequency - creating more accurate measurements
- Features R* measurement - Calculates earth ground impedance at 55 Hz to accurately reflect the earth ground resistance that a fault-to-earth would see
- User programmable limits
- Continuity with audible alert
- Selective earth ground rod testing with 1 clamp
- Capable of 2-pole resistance measurement AC
- Stakeless earth ground rod testing with 2 clamps
- 3-Pole & 4-Pole earth ground measurements, 4-Pole soil resistivity measurements, 2-Pole & 4-Pole resistance measurements DC
- Switchable voltage 20V/48V
- 2 year warranty
Specifications: | Fluke 1625-2 Geo Earth Ground Tester | |||
General Specifications | ||||
Memory | Internal memory storage up to 1500 records accessible via USB port | |||
Measuring Function | Interference voltage and frequency, earthing resistance 3- and 4-pole with/without clip-on current transformer, resistance 2-pole with AC, 2- and 4-pole with DC | |||
Display | 4 digit (2999 Digit) - 7 segment liquid crystal display, with improved visibility | |||
Operation | Central rotary switch and function keys | |||
Temperature Range | ||||
Operating temperature | -10°C to 50°C (14°F to 122°F) | |||
Storage temperature | -30°C to 60°C (-22°F to 140°F) | |||
Temperature coefficient | ±0.1% of reading/°C < 18°C > 28°C | |||
Type of protection | IP56 for case, IP40 for battery door according to EN60529 | |||
Max voltage | Warning – socket "clamp" to socket E, ES, S or H | |||
Urms = 0 V | ||||
Sockets E, ES, S or H to each other in any combination, max. Urms = 250 V (pertains to misuse) | ||||
Safety | Protection by double and/or reinforced insulation. Max. 50 V to earth per IEC61010-1. 300V CAT II, Pollution degree 2 | |||
Quality standard | Developed, designed and manufactured to comply with DIN ISO 9001 | |||
External field influence | Complies with DIN 43780 (8/76) | |||
Auxiliary power | 6 x 1.5 V alkaline (IEC LR6 or type AA) | |||
Battery life span | With IEC LR6/type AA: typ. 3,000 measurements (RE+RH = 1 kO) | |||
With IEC LR6/type AA: typ. 6,000 measurements (RE + RH > 10 kO) | ||||
Dimensions (W x H x D) | 250 x 133 x 187 mm (9.75 x 5.25 x 7.35 in) | |||
Weight | = 1.1 kg (2.43 lb) without accessories 7.6 kg (16.8 lb) incl. accessories and batteries in carrying case | |||
Case material | Polyester | |||
Measurement of Interference Voltage DC + AC (UST) | ||||
Measuring limits of error: method | Full wave rectification | |||
Measuring range | 1 V to 50 V | |||
Display range | 0.0 V to 50 V | |||
Resolution | 0.1 V | |||
Frequency range | DC/AC 45 Hz to 400 Hz sine | |||
Accuracy | ±(5% of rdg + 5 digit) | |||
Measuring sequence | Approx. 4 measurements/s | |||
Internal resistance | Approx. 1.5 MO | |||
Max. overload | Urms = 250 V | |||
Measurement of Interference Frequency (F) | ||||
Measuring limits of error: method | Measurement of oscillation period of the interference voltage | |||
Measuring range | 6.0 Hz to 400 Hz | |||
Display range | 16.0 Hz to 299.9 Hz to 999 Hz | |||
Resolution | 0.1 Hz to 1 Hz | |||
Range | 1 V to 50 V | |||
Accuracy | ±(1% of rdg + 2 digit) | |||
Earthing Resistance (RE) | ||||
Measuring method | Current and voltage measurement with probe as IEC61557-5 | |||
Open circuit voltage | 20/48 V, AC | |||
Short circuit current | 250 mA AC | |||
Measuring frequency | 94, 105, 111, 128 Hz selected manually or automatic. (AFC) 55 Hz in function R1 | |||
Noise rejection | 120 dB (16 2/3 , 50 , 60, 400 Hz) | |||
Max. overload | Urms = 250 V | |||
Electrical Measurement Specifications | ||||
Intrinsic Error or Influence Quantity | Reference Conditions or Specified Operating Range | Designation Code | Requirements or Test in Accordance with the Relevant Parts of IEC 1557 | Type of Test |
Intrinsic error | Reference conditions | A | Part 5, 6.1 | R |
Position | Reference position ±90° | E1 | Part 1, 4.2 | R |
Supply voltage | At the limits stated by the manufacturer | E2 | Part 1, 4.2, 4.3 | R |
Temperature | 0°C and 35°C | E3 | Part 1, 4.2 | T |
Series interference voltage | See 4.2 and 4.3 | E4 | Part 5, 4.2, 4.3 | T |
Resistance of the probes and auxiliary earth electrodes | 0 to 100 x RA but = 50 kO | E5 | Part 5, 4.3 | T |
System frequency | 99% to 101% of the nominal frequency | E7 | Part 5, 4.3 | T |
System voltage | 85% to 110% of the nominal voltage | E8 | Part 5, 4.3 | T |
Operating error | B = ±(|A| + 1,15 vE21 E22 E23 E24 E25 E26 ) | Part 5, 4.3 | R | |
B[%] = ± B/fiducial value x 100% | ||||
A = intrinsic error | ||||
En = variations | ||||
R = routine test | ||||
T = type test | ||||
Measuring range | 0.020 O to 300 kO | |||
Display range | 0.001 O to 2.999 O | |||
3.00 O to 29.99 O | ||||
30.0 O to 299.9 O | ||||
0.300 kO to 2.999 kO | ||||
3.00 kO to 29.99 kO | ||||
30.0 kO to 299.9 kO | ||||
Resolution | 0.001 O | |||
0.01 O | ||||
0.1 O | ||||
1 O | ||||
10 O | ||||
100 O | ||||
Accuracy | ±(2% of rdg + 2 digit) | |||
Operating error | ±(5% of rdg + 5 digit) | |||
Measuring time | Typical 8 seconds with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies | |||
Additional error because of probe-and auxiliary earth electrode resistance | RH(RS + 2000 O)/RE x 1.25 x 10-6% + 5 digits | |||
Measuring error of RH and RS | Typ. 10% of RE + RS + RH | |||
Max. probe resistance | = 1 MO | |||
Max. auxiliary earth electrode resistance | = 1 MO | |||
Automatic check if error is kept within the limits required by IEC61557-5. If after a measurement of probe-, auxiliary earth electrode- and earthing resistance, a measurement error of higher than 30% is assumed because of the influencing conditions, the display shows a warning symbol and a notice that RS or RH are too high. | ||||
Automatic Switchover of Measuring Resolution in Dependence to Auxiliary Earth Electrode Resistance RH | ||||
RH with Umeas = 48 V | < 300 O | |||
< 6 O | ||||
< 60 O | ||||
< 600 O | ||||
RH with Umeas = 20 V | < 250 O | |||
< 2.5 kO | ||||
< 25 kO | ||||
< 250 kO | ||||
Resolution | 1 mO | |||
10 mO | ||||
100 mO | ||||
1 O | ||||
Selective Measurement of the Earthing Resistance (RE Clamp) | ||||
Measuring method | Current and voltage measurement with probe as per EN61557-5 and current measurement in the individual branch with additional current transformer (patent applied for). | |||
Open circuit voltage | 20/48 V AC | |||
Short circuit current | 250 mA AC | |||
Measuring frequency | 94, 105, 111, 128 Hz selected manually or automatically (AFC), 55 Hz (R1) | |||
Noise rejection | 120 dB (162/3, 50, 60, 400 Hz) | |||
Max. overload | Max. Urms = 250 V (measurement will not be started) | |||
Measuring range | 0.020 O to 300 kO | |||
Display range | 0.001 O to 2.999 O | |||
3.00 O to 29.99 O | ||||
30.0 O to 299.9 O | ||||
0.300 kO to 2.999 kO | ||||
3.00 kO to 29.99 kO | ||||
Resolution | 0.001 O | |||
0.01 O | ||||
0.1 O | ||||
1 O | ||||
10 O | ||||
Accuracy | ±(7% of rdg + 2 digit) | |||
Operating error | ±(10% of rdg + 5 digit) | |||
Additional error because of probe- and auxiliary earth typ. electrode resistance | RH(RS + 2000 ?)/RETOTAL x 1.25 x 10-6% + 5 digits | |||
Measuring error of RH and RS | Typ. of 10% of RETOTAL + RS + RH | |||
Measuring time | Typ. 8 sec. with a fixed frequency 30 sec. max. with AFC and complete cycle of all measuring frequencies. | |||