Fluke 87-5 Industrial TRMS meter has enhanced measurement functions, troubleshooting capabilities, resolution, and precision to diagnose and fix more issues on motor drives, in plant automation, power distribution, and electro-mechanical equipment. This tester has a unique function for precise voltage and frequency reading on variable speed motor drives and other electrically loud gear.
Chracteristics: | Fluke 87-5 TRMS Digital Multimeter for Industrial Applications |
User-determined filter for precise voltage and frequency readings on motor drives | |
6000 counts, 3-3/4 digits | |
4-1/2 digit mode for accurate readings (20,000 counts), with two-level bright white backlight | |
Measure up to 10 Amps, 20 Amps for up to 30 sec. | |
Incorporated thermometer allows for a lighter load to carry (TC probe included) | |
Frequency to 200 kHz and % duty cycle | |
Resistance, continuity and diode testing capabilities | |
10,000 & mu F capacitance range for components and motor caps | |
Min/Max/Average recording with Min/Max Alert to auto-determine fluctuations | |
Peak-capture to store transients as fast as 250 & Icirc & frac14 s | |
Relative mode to eliminate test lead intrusion from low ohms readings | |
Automatic/manual ranging to get the most use out of the product | |
Touch Hold to seize stable measurements and avoid noisy signals | |
Analog bargraph for fast altering or unsteady signals | |
Audible input warning against improper use of input jacks | |
Enhanced selectable sleep mode for battery longevity | |
Access door for quick battery swaps without breaking the calibration seal | |
"Classic" design with new detachable holster that has internal test lead and probe storage places | |
Unique function for precise readings of loud pulse-width modulated Alternating Current voltage. | |
Measures precisely at the ASD and at the motor terminals |
Specifications: | Fluke 87-5 Industrial True RMS Multimeter |
Voltage DC | Maximum Voltage: 1000V Accuracy: +/-(0.05%+1) Maximum Resolution: 10 μV |
Voltage AC | Maximum Voltage: 1000V Accuracy: +/-(0.7%+2) True RMS AC Bandwidth: 20kHz* *with low pass filter; 3db @ 1kHz Maximum Resolution: 0.1 mV |
Current DC | Maximum Amps: 10A (20 A for 30 seconds maximum) Amps Accuracy: +/-(0.2%+2) Maximum Resolution: 0.01 μA |
Current AC | Maximum Amps: 10A (20 A for 30 seconds maximum) Amps Accuracy: +/-(1.0%+2) True RMS Maximum Resolution: 0.1 μA |
Resistance | Maximum Resistance: 50 MΩ Accuracy: +/-(0.2%+1) Maximum Resolution: 0.1Ω |
Capacitance | Maximum Capacitance 9,999 μF Accuracy +/-(1%+2) Maximum Resolution 0.01 nF |
Frequency | Maximum Frequency 200 kHz Accuracy +/-(0.005%+1) Maximum Resolution 0.01 Hz |
Duty Cycle | Maximum Duty Cycle 99.9% Accuracy +/-(0.2% per khz +0.1%) Maximum Resolution 0.1% |
Temperature Measurement | -200.0 to 1090 Degrees C -328.0 to 1994.0 Degrees F excluding probe |
80 BK Temperature Probe | -40.0 to 260 Degrees C -40.0 to 500 Degrees F, 2.2 Degrees C or 2% whichever is greater |
Conductance | Maximum Conductance 60.00 nS Accuracy +/-(1.0%+10) Maximum Resolution 0.01 nS |
Diode | Range: 3 V Resolution: 1 mV Accuracy: +/-(2 % + 1) |
Duty Cycle Range | Accuracy: Within +/-(0.2% per kHz + 0.1 %) |
Operating Temperature | -20 to +55 Degrees C |
Storage Temperature | -40 to +60 Degrees C |
Humidity (Without Condensation) | 0% - 90% (0 to 35 Degrees C) 0% - 70% (35 to 55 Degrees C) |
Operating Altitude | 2000 m |
Overvoltage category | EN 61010-1 to 1000 V CAT III, 600V CAT IV |
Agency Approvals | UL, CSA, TUV, VDE listed |
Size | 201 x 98 x 52 mm (with holster) |
Weight | 355 g |
Weigh With Holster and Flex-Stand | 624 g |
Display | Digital: 6000 counts updates 4/sec. (19,999 counts in high-resolution mode.) Analog: 32 segments, updates 40/sec. Frequency: 19,999 counts, updates 3/sec at > 10 Hz. |
Battery Life | Alkaline: ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010-1:2001 |
Vibration | Per MIL-PRF-28800 for a Class 2 instrument |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.