Fluke I2000 Flex AC Current Probe is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000A when used in conjunction with multimeters, recorders or data loggers.
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas. Mfg part Fluke 2584912.
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm
- CAT III 600V safety rating
Electrical specifications | |
Current ranges | 20 A 200 A 200 A AC rms |
Output sensitivity (AC-coupled) | 100 mV 10 mV 1 mV 1 mV per A |
Load impedance | 100 k ohm minimum |
Accuracy | at +25 degrees C ± 1 percent of range (45 Hz to 65 Hz) |
Linearity | 10 percent to 100 percent of range ± 0.2 percent of reading |
Noise | 8 mV ac rms (30 A) 2 mV ac rms (300 A, 3000 A) |
Frequency range | 10 Hz to 20 kHz (-3 dB) |
Phase error | < ± 1 degree (45 Hz to 65 Hz) ± 10 degree (at 20 kHz) |
Position sensitivity | with cable > 25 mm from the coupling ± 2 percent of range |
External field | with cable > 200 mm from the head ± 1 percent of range |
Power supply | 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator |
Temperature Coefficient | ± 0.08 percent of reading per degrees C |
Working voltage see Safety standards section | 600 V AC rms or DC |
General Specifications | |
Head Circumference | 610 mm (24 in) |
Head cable diameter | 14.3 mm (0.56 in) |
Head bend radius | 38.1 mm (1.5 in) |
Cable length (head to electronics) | 2 m (6.56 ft) |
Output connection | Molded 4 mm safety plugs (not integrated) |
Operating temperature range | 0 degrees C to +70 degrees C (32 degrees F to 158 degrees F) (head and electronics) |
Storage temperature range | -40 degrees C to +105 degrees C (-40 degrees F to 221 degrees F) (head) -20 degrees C to +85 degrees C (-4 degrees F to 185 degrees F) (electronics) |
Operating humidity | 15 pwecwnr to 85 percent (non-condensing) |
Weight | 180 g (6.34 oz) (head) 190 g (6.70 oz) (electronics) |
Safety standards | EN 61010-1: 2001 EN 61010-2-032: 2002 EN 61010-031: 2002 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz. |
EMC standards | EN 61326: 1998 +A1, A2, and A3 |
Dimensions | HxWxD 116 mm x 68.5 mm x 30 mm (4.56 in x 2.69 in x 1.18 in) |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.