Fluke I3000S Flex-24 AC Current Clamp. The i3000s Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers.
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas. Mfg part Fluke 2584888. Fluke parts and accessories.
- Maximum conductor diameter 178 mm (7 in.)
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
Linearity | 10 percent to 100 percent of range ± 0.2 percent of reading |
Accuracy | at +25 degrees C ± 1 percent of range (45 Hz to 65 Hz) |
Load impedance | 100 k ohm minimum |
Output sensitivity (AC-coupled) | 100 mV 10 mV 1 mV per A |
Current ranges | 30 A 300 A 3000 A AC rms |
Electrical specifications | |
Noise | 8 mV ac rms (30 A) 2 mV ac rms (300 A, 3000 A) |
Frequency range | 10 Hz to 50 kHz (-3 dB) |
Phase error | < ± 1 degree (45 Hz to 65 Hz) ± 10 degree (at 20 kHz) |
Position sensitivity | with cable > 25 mm from the coupling ± 2 percent of range |
External field | with cable > 200 mm from the head ± 1 percent of range |
Power supply | 2 x AA/MN 1500/LR6 Alkaline, , 400 hours, low battery indicator or dedicated external power supply |
Temperature Coefficient | ± 0.08 percent of reading per degrees C |
Working voltage see Safety standards section 600 V AC rms or DC | |
General Specifications | |
Head Circumference | 915 mm (36 in.) |
Head cable diameter | 14.3 mm (0.56 in) |
Head bend radius | 38.1 mm (1.5 in) |
Cable length (head to electronics) | 2 m (6.56 ft) |
Output connection | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter |
Operating temperature range | 20 degrees C to +90 degrees C (-4 degrees F to 190 degrees F) (head) -20 degrees C to +85 degrees C (-4 degrees F to 185 degrees F) (electronics) |
Storage temperature range | -40 degrees C to +105 degrees C (-40 degrees F to 221 degrees F) (head) -20 degrees C to +85 degrees degrees C (-4 degrees F to 185 degrees F) (electronics) |
Operating humidity | 15 percent to 85 percent (non-condensing) |
Weight | 180 g (0.396 lb) (head) 190 g (0.419 lb) (electronics) |
Safety standards | BS EN 61010-1: 2001 BS EN 61010-2-032: 2002 BS EN 61010-031: 2002 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V AC rms or dc and frequencies below 1 kHz. |
EMC standards | EN 61326: 1998 +A1, A2, & A3 |
Maximum conductor size | 610 mm or 914 mm, depending on model |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.