General Tools KHV57030 HVAC DMM Kit with IR Thermometer combines two excellent electrical tools in one convenient kit for less than the cost of buying the units alone. General Tools KHVP57068 includes both the DMM570 TRMS Multimeter and the IRT730K infrared thermometer, as well as useful accessories including thermocouples, alligator clips, test leads, and a custom padded carrying case.
- General Tools KHV57030 HVAC DMM Kit with IR Thermometer
- DMM570 TRMS Multimeter with NCV Detection
- Designed with 19 functions and 48 ranges
- Takes measurements for AC/DC voltage, AC/DC current, resistance, capacitance, frequency, and duty cycle
- Takes K-type thermocouple temperature measurements
- Tests for diode integrity and continuity
- TRMS measurements for greater accuracy
- Water, dust, and oil protection to IP54
- Resistant to a 6ft. drop
- CAT III 1000V, CAT IV 600V safety rated
- Manual or auto ranging
- Non-contact voltage detection
- Avoid ghost voltage readings with Lo-Z low-impedance mode
- 3-3/4 digit (6,600 count) dual readout LCD is backlit and easy to read
- Fast response bar-graph has 66 segments
- MIN/MAX, Hold and Zero functions
- Auto Power-off
- Features magnetic hanging strap
- IRT730K 30:1 IR Thermometer
- Very large measurement range
- Emissivity is adjustable
- Target area outlined by laser targeting ring
- K type thermocouple probe included for contact temperature measurement
- Release trigger to hold measurement
- 100 data sets stored and recalled
- Display Min/Max/Avg/Dif
- High and low temperature alarms are user programmable
- Backlit LCD is large and features dual 5 digit readouts
- Auto power off to save energy
- Reads in °F or °C
- Battery status indicator
- General Tools KHV57030 includes:
- Pipe wrap thermocouple, "K " type bead thermocouple probe, "K " type stem thermocouple probe,
Adapter for thermocouples with spade lugs, Pair of CAT III 1000V rated test leads with alligator clips,
Magnetic meter hanging strap, Custom padded carrying case, Batteries and user's manuals
Specifications: | General Tools KHV57030 HVAC DMM Kit with IR Thermometer |
AC/DC Voltage Measurement Range | 0 to 660mV/6.6V/66V/1000V |
DC Voltage Measurement Accuracy | ±(0.5% of reading + 2 digits) |
AC Voltage Measurement Accuracy | ±(1% of reading + 2 digits) |
Voltage Measurement Resolution | 10µV |
NCV Detection Range | 12 to 600VAC |
Overvoltage Protection Level | 1kV |
AC/DC Current Measurement Ranges | 0 to 6.6µA/66µA/660µA/6.6mA/6.6mA/660mA/10A |
Current Measurement Accuracy | ±(1.2% of reading + 2 digits) |
Resistance Measurement Ranges | 0 to66?/6.6k?/66k?/660k?/6.6M?/66M? |
Resistance Measurement Accuracy | ±(0.8% of reading + 2 digits) |
Capacitance Measurement Ranges | 0 to 6nF/60nF/600nF/6µF/60µF/600µF/6,000µF/60,000µF |
Capacitance Measurement Accuracy | ±(4% of reading + 5 digits) |
Temperature Measurement Ranges | 0 to -40°C/-4°C/4°C/40°C/400°C |
Temperature Measurement Accuracy | ±2% of reading |
Frequency Measurement Ranges (in AC Voltage mode w/12VAC input) | 0 to 10Hz/100Hz/1kHz |
Frequency Measurement Accuracy (in AC voltage mode) | ±(1.5% of reading + 5 digits) |
Frequency Measurement Ranges (in Frequency mode w/5V p-p 1kHz square wave input) | 0 to 10kHz/100kHz/1MHz/10MHz |
Frequency Measurement Accuracy in Frequency mode | ±(0.3% of reading + 5 digits) |
Duty Cycle Measurement Range (w/5V p-p 1kHz square wave input) | 1 to 99% |
Continuity Threshold | <50? |
Diode Integrity Check Voltage | up to 2.7V |
Data Update Frequency | 3X/sec |
Auto Power Off Trigger | 15 minutes of front-panel inactivity |
Operating Temperature | 32° to 104°F (0° to 40°C) |
Dimensions | 7.1 x 3.4 x 2.0 in. (176 x 84 x 54mm) |
Weight | 12 oz. (342g) |
Power Source | 1 "9V " battery (included) |
General Tools IRT730K 30:1 IR Thermometer | |
IRT Distance to Spot (D:S) Ratio | 30:1 |
IRT Emissivity | Adjustable from 0.1 to 1.0 in 0.01 steps with default of 0.95 |
IRT Measurement Range | -58° to 1400°F (-50° to 760°C) |
IRT Measurement Accuracy | ±9°F (±5°C) from -58°F to -4°F; ±1.5% of reading or +3.6°F(2°C), whichever is greater, from -4° to 392°F (-20° to 200°C); ±2% of reading or +3.6°F(2°C), whichever is greater, from 392° to 800°F(200° to 427°C); ±1.5% of reading or +1.8°F(1°C), whichever is greater, from 800° to1400°F (427° to 760°C) |
IRT Measurement Resolution | 0.1°F (0.1°C) |
Range/Accuracy of Included "K " Type Stem Thermocouple Probe | -58° to 1112°F (-50° to 600°C)/ ±(2% + 2 digits) |
Response Time | <500ms |
Laser Power | <1mW (Class 2) @ wavelength of 630 to 670nm |
Spectral Response | 8 to 14m |
Operating Temperature | 41° to 104°F (5° to 45°C) @10 to 90%RH |
Auto Power Off Trigger | 30 seconds of front-panel inactivity |
Dimensions | 6.9 x 5.1 x 1.7 in. (175 x 130 x 42mm) |
Weight | 7.4 oz. (210g) |
Power Source | 1 "9V " battery (included) |
Proposition 65 Warning for California Residents: This product can expose you to chemicals including Benzene, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
Applications: | General Tools KHV57030 HVAC DMM Kit with IR Thermometer |
Designed to locate overheating components in industrial and electrical applications |