Accuenergy AcuTEMS-OA Series Temperature Nickel RTD with 1 kΩ, outside

Model: AcuTEMS-OA-A-06-1

Accuenergy AcuTEMS-OA Series Temperature Nickel RTD with 1 kΩ, outside

Model: AcuTEMS-OA-A-06-1

This outdoor air temperature RTD provides accurate ambient temperature measurements and is housed in a NEMA 4 plastic (IP65) enclosure. It uses a nickel RTD with a nominal resistance of 1 kΩ.

This outdoor air temperature RTD provides accurate ambient temperature measurements and is housed in a NEMA 4 plastic (IP65) enclosure. It uses a nickel RTD with a nominal resistance of 1 kΩ.

Sale Price $90.53 USD
Regular Price $98.40 USD
Availability 2 to 3 Weeks
Quantity

Accuenergy AcuTEMS-OA-A-06-1 Offers

The AcuTEMS OA series sensor measures outdoor ambient air temperature with up to ±0.36°F (±0.2°C) accuracy. Designed to be mounted on a vertical surface outdoors in a shaded location, the sensor comes with an IP65 enclosure for protection against outdoor elements. The AcuTEMS OA features multiple RTD, thermistor, and transmitter output options, and it is ideal for HVAC/R systems to maintain comfort and ensure efficient equipment operation. For applications under direct sunlight, install the AcuHUM OAW instead, which comes with a sixlayered weather shield for extra UV protection, boosted ventilation and improved accuracy.

The AcuTEMS OA series sensor measures outdoor ambient air temperature with up to ±0.36°F (±0.2°C) accuracy. Designed to be mounted on a vertical surface outdoors in a shaded location, the sensor comes with an IP65 enclosure for protection against outdoor elements. The AcuTEMS OA features multiple RTD, thermistor, and transmitter output options, and it is ideal for HVAC/R systems to maintain comfort and ensure efficient equipment operation. For applications under direct sunlight, install the AcuHUM OAW instead, which comes with a sixlayered weather shield for extra UV protection, boosted ventilation and improved accuracy.

How to choose an Outside Air Temperature Sensor?

How to choose an Outside Air Temperature Sensor?

Outside air temperature sensor designed to measure ambient air temperature outside buildings and facilities using precision sensing elements, including 100Ω Platinum, 1kΩ Platinum, Nickel RTDs, and 10kΩ Type II, Type III, or 20KΩ thermistors. The sensor is installed vertically in a shaded outside location using screw mounting and push-button wiring. An IP65-rated enclosure protects against dust, moisture, and other outdoor elements. With a response time under 10 seconds, the sensor transmits temperature data to building automation system controllers to support efficient operation of economizers, heating, and cooling systems, ensuring optimal indoor comfort and reliable HVAC/R performance.

Outside air temperature sensor designed to measure ambient air temperature outside buildings and facilities using precision sensing elements, including 100Ω Platinum, 1kΩ Platinum, Nickel RTDs, and 10kΩ Type II, Type III, or 20KΩ thermistors. The sensor is installed vertically in a shaded outside location using screw mounting and push-button wiring. An IP65-rated enclosure protects against dust, moisture, and other outdoor elements. With a response time under 10 seconds, the sensor transmits temperature data to building automation system controllers to support efficient operation of economizers, heating, and cooling systems, ensuring optimal indoor comfort and reliable HVAC/R performance.

Features

  • Push-in button terminal blocks and quick release enclosure screws enable swift and convenient installation
  • Push-in button terminal blocks and quick release enclosure screws enable swift and convenient installation
  • IP65 enclosure provides superior protection against dust and moisture ingress
  • IP65 enclosure provides superior protection against dust and moisture ingress
  • 100Ω Platinum, 1kΩ Platinum/Nickel RTDs, and 10kΩ Type II/Type III, 20kΩ thermistors available for different BAS controller requirements
  • 100Ω Platinum, 1kΩ Platinum/Nickel RTDs, and 10kΩ Type II/Type III, 20kΩ thermistors available for different BAS controller requirements
  • Three wire terminals provide flexibility for 2-wire or 3-wire installation
  • Three wire terminals provide flexibility for 2-wire or 3-wire installation
  • 4 to 20 mA and 0 to 10 V DC output options for different BAS controllers and applications
  • 4 to 20 mA and 0 to 10 V DC output options for different BAS controllers and applications

Applications

  • Economizer Control
  • Economizer Control
  • Weather Compensation
  • Weather Compensation
  • HVAC/R System Optimization
  • HVAC/R System Optimization

Accuenergy AcuTEMS-OA-A-06-1 Specifications

Specifications for the AcuTEMS-OA-A-06-1
Sensor Accuracy ±0.9°F at 77°F (±0.5°C at 25°C)
Sensor Accuracy ±0.9°F at 77°F (±0.5°C at 25°C)
Temperature Output Resistive output (thermistor or RTD)
Temperature Output Resistive output (thermistor or RTD)
Temperature Sensor 1kΩ Nickel RTD
Temperature Sensor 1kΩ Nickel RTD
Enclosure NEMA 4 Plastic (IP65)
Enclosure NEMA 4 Plastic (IP65)
Electrical
Transmitter Voltage Power 19.2 to 28.8 V AC or V DC
Transmitter Voltage Power 19.2 to 28.8 V AC or V DC
Transmitter Current Power 19.2 to 28.8 V DC (RL=500Ω)
8.5 to 35 V DC (RL=0Ω)
Transmitter Current Power 19.2 to 28.8 V DC (RL=500Ω)
8.5 to 35 V DC (RL=0Ω)
Transmitter Output 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires)
Transmitter Output 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires)
Output Load ≤500Ω (Current), ≥2KΩ (Voltage)
Output Load ≤500Ω (Current), ≥2KΩ (Voltage)
Temperature Performance
Temperature Transmitter Measurement Range -40 to 140°F (-40 to 60°C)
Temperature Transmitter Measurement Range -40 to 140°F (-40 to 60°C)
Response Time <10 s
Response Time <10 s
Environmental
Operating Temperature Range -40 to 158°F (-40 to 70°C) at 0 to 95% RH
(Non-Condensing)
Operating Temperature Range -40 to 158°F (-40 to 70°C) at 0 to 95% RH
(Non-Condensing)
Storage Temperature -22 to 176°F (-30 to 80°C)
Storage Temperature -22 to 176°F (-30 to 80°C)
Certifications and Warranty
Enclosure Material Fire retardant polycarbonate (UL94V-0)
Enclosure Material Fire retardant polycarbonate (UL94V-0)
Protection IP65
Protection IP65
Agency Approvals CE
Agency Approvals CE
Warranty 5 Years
Warranty 5 Years
Mechanical
Mounting Screw surface mount
Mounting Screw surface mount
Wiring Connection Push button terminal blocks (2 wire or 3 wire)
Wiring Connection Push button terminal blocks (2 wire or 3 wire)
Weight 0.53 lbs (240 g)
Weight 0.53 lbs (240 g)
Click here for complete specifications on the Accuenergy AcuTEMS-OA-A-06-1

What's included with the Accuenergy AcuTEMS-OA-A-06-1

  • Outdoor Ambiant Air Temperature Sensor
  • Outdoor Ambiant Air Temperature Sensor
  • Five-Years Warranty
  • Five-Years Warranty

Ask a question about Accuenergy AcuTEMS-OA Series Temperature Nickel RTD with 1 kΩ, outside

Customer Reviews for the Accuenergy AcuTEMS-OA-A-06-1

Accuenergy AcuTEMS-OA-A-06-1 Offers

The AcuTEMS OA series sensor measures outdoor ambient air temperature with up to ±0.36°F (±0.2°C) accuracy. Designed to be mounted on a vertical surface outdoors in a shaded location, the sensor comes with an IP65 enclosure for protection against outdoor elements. The AcuTEMS OA features multiple RTD, thermistor, and transmitter output options, and it is ideal for HVAC/R systems to maintain comfort and ensure efficient equipment operation. For applications under direct sunlight, install the AcuHUM OAW instead, which comes with a sixlayered weather shield for extra UV protection, boosted ventilation and improved accuracy.

The AcuTEMS OA series sensor measures outdoor ambient air temperature with up to ±0.36°F (±0.2°C) accuracy. Designed to be mounted on a vertical surface outdoors in a shaded location, the sensor comes with an IP65 enclosure for protection against outdoor elements. The AcuTEMS OA features multiple RTD, thermistor, and transmitter output options, and it is ideal for HVAC/R systems to maintain comfort and ensure efficient equipment operation. For applications under direct sunlight, install the AcuHUM OAW instead, which comes with a sixlayered weather shield for extra UV protection, boosted ventilation and improved accuracy.

How to choose an Outside Air Temperature Sensor?

How to choose an Outside Air Temperature Sensor?

Outside air temperature sensor designed to measure ambient air temperature outside buildings and facilities using precision sensing elements, including 100Ω Platinum, 1kΩ Platinum, Nickel RTDs, and 10kΩ Type II, Type III, or 20KΩ thermistors. The sensor is installed vertically in a shaded outside location using screw mounting and push-button wiring. An IP65-rated enclosure protects against dust, moisture, and other outdoor elements. With a response time under 10 seconds, the sensor transmits temperature data to building automation system controllers to support efficient operation of economizers, heating, and cooling systems, ensuring optimal indoor comfort and reliable HVAC/R performance.

Outside air temperature sensor designed to measure ambient air temperature outside buildings and facilities using precision sensing elements, including 100Ω Platinum, 1kΩ Platinum, Nickel RTDs, and 10kΩ Type II, Type III, or 20KΩ thermistors. The sensor is installed vertically in a shaded outside location using screw mounting and push-button wiring. An IP65-rated enclosure protects against dust, moisture, and other outdoor elements. With a response time under 10 seconds, the sensor transmits temperature data to building automation system controllers to support efficient operation of economizers, heating, and cooling systems, ensuring optimal indoor comfort and reliable HVAC/R performance.

Features

  • Push-in button terminal blocks and quick release enclosure screws enable swift and convenient installation
  • Push-in button terminal blocks and quick release enclosure screws enable swift and convenient installation
  • IP65 enclosure provides superior protection against dust and moisture ingress
  • IP65 enclosure provides superior protection against dust and moisture ingress
  • 100Ω Platinum, 1kΩ Platinum/Nickel RTDs, and 10kΩ Type II/Type III, 20kΩ thermistors available for different BAS controller requirements
  • 100Ω Platinum, 1kΩ Platinum/Nickel RTDs, and 10kΩ Type II/Type III, 20kΩ thermistors available for different BAS controller requirements
  • Three wire terminals provide flexibility for 2-wire or 3-wire installation
  • Three wire terminals provide flexibility for 2-wire or 3-wire installation
  • 4 to 20 mA and 0 to 10 V DC output options for different BAS controllers and applications
  • 4 to 20 mA and 0 to 10 V DC output options for different BAS controllers and applications

Applications

  • Economizer Control
  • Economizer Control
  • Weather Compensation
  • Weather Compensation
  • HVAC/R System Optimization
  • HVAC/R System Optimization

Accuenergy AcuTEMS-OA-A-06-1 Specifications

Specifications for the AcuTEMS-OA-A-06-1
Sensor Accuracy ±0.9°F at 77°F (±0.5°C at 25°C)
Sensor Accuracy ±0.9°F at 77°F (±0.5°C at 25°C)
Temperature Output Resistive output (thermistor or RTD)
Temperature Output Resistive output (thermistor or RTD)
Temperature Sensor 1kΩ Nickel RTD
Temperature Sensor 1kΩ Nickel RTD
Enclosure NEMA 4 Plastic (IP65)
Enclosure NEMA 4 Plastic (IP65)
Electrical
Transmitter Voltage Power 19.2 to 28.8 V AC or V DC
Transmitter Voltage Power 19.2 to 28.8 V AC or V DC
Transmitter Current Power 19.2 to 28.8 V DC (RL=500Ω)
8.5 to 35 V DC (RL=0Ω)
Transmitter Current Power 19.2 to 28.8 V DC (RL=500Ω)
8.5 to 35 V DC (RL=0Ω)
Transmitter Output 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires)
Transmitter Output 4 to 20 mA (2 Wires) or 0 to 10 V DC (3 Wires)
Output Load ≤500Ω (Current), ≥2KΩ (Voltage)
Output Load ≤500Ω (Current), ≥2KΩ (Voltage)
Temperature Performance
Temperature Transmitter Measurement Range -40 to 140°F (-40 to 60°C)
Temperature Transmitter Measurement Range -40 to 140°F (-40 to 60°C)
Response Time <10 s
Response Time <10 s
Environmental
Operating Temperature Range -40 to 158°F (-40 to 70°C) at 0 to 95% RH
(Non-Condensing)
Operating Temperature Range -40 to 158°F (-40 to 70°C) at 0 to 95% RH
(Non-Condensing)
Storage Temperature -22 to 176°F (-30 to 80°C)
Storage Temperature -22 to 176°F (-30 to 80°C)
Certifications and Warranty
Enclosure Material Fire retardant polycarbonate (UL94V-0)
Enclosure Material Fire retardant polycarbonate (UL94V-0)
Protection IP65
Protection IP65
Agency Approvals CE
Agency Approvals CE
Warranty 5 Years
Warranty 5 Years
Mechanical
Mounting Screw surface mount
Mounting Screw surface mount
Wiring Connection Push button terminal blocks (2 wire or 3 wire)
Wiring Connection Push button terminal blocks (2 wire or 3 wire)
Weight 0.53 lbs (240 g)
Weight 0.53 lbs (240 g)
Click here for complete specifications on the Accuenergy AcuTEMS-OA-A-06-1

What's included with the Accuenergy AcuTEMS-OA-A-06-1

  • Outdoor Ambiant Air Temperature Sensor
  • Outdoor Ambiant Air Temperature Sensor
  • Five-Years Warranty
  • Five-Years Warranty

Ask a question about Accuenergy AcuTEMS-OA Series Temperature Nickel RTD with 1 kΩ, outside

Customer Reviews for the Accuenergy AcuTEMS-OA-A-06-1

More Accuenergy Products