Reading space temperature from a single-gang box or a bare wall opening, this room sensor uses a 10,000 ohm Type II thermistor behind a four-way air flow enclosure that keeps the sensing element clear of self-heating. Screw terminal blocks take every connection to the building network, and a hex-secured cover resists casual removal.
Reading space temperature from a single-gang box or a bare wall opening, this room sensor uses a 10,000 ohm Type II thermistor behind a four-way air flow enclosure that keeps the sensing element clear of self-heating. Screw terminal blocks take every connection to the building network, and a hex-secured cover resists casual removal.
The ACI Thermistor Room Series combines option flexibility with attractive styling in our "-R2" or "-R" style enclosures which include four-way air flow design to minimize self-heating to the sensor. These enclosures are offered in a White "-R2" or Beige "-R" color depending on the enclosure style. These units are designed to be mounted over a single gang junction box or hole in the wall using drywall anchors. Screw terminal blocks are available for making all connections to your building management system (network).
Features
Applications
| Set Point Tolerance | ±10 % of range |
| Override Options | Short Thermistor (Default); Field (Jumper) Selectable "Dry Contact" Closure (Separate Input); Short Set Point available upon request |
| Power Dissipation Constant | 3 mW / °C |
| Sensor Type | Thermistor |
| Connections | Screw Terminal Blocks |
| Terminal Block Torque Rating | 0.5 Nm minimum; 0.6 Nm maximum |
| Wire Size | 1.31 mm2 (16 AWG) to 0.129 mm2 (26 AWG) |
| Number Temperature Sensing Points | One Sensor Output at 25 °C (77 °F) |
| Operating Range | 1.5 °C to 50 °C (35 °F to 122 °F) |
| Sensor Curve | Non-Linear, NTC (Negative Temperature Coefficient) |
| Operating Humidity Range | 10 % to 95 % RH, non- condensing |
| Storage Temperature Range | -40 °C to 65 °C (-40 °F to 149 °F) |
| Enclosure Material | Color | "-R2" Enclosure: ABS Plastic, White, UL94-HB "-R" Enclosure: ABS Plastic, Beige UL94-HB |
| Product Dimensions (L x W x H) | 4.50 x 2.70 x 1.10" (114.3 x 68.6 x 27.9 mm) |
| Product Weight | 0.10 lbs (48 g) |
| Agency Approvals | CE**, UKCA, RoHS2, WEEE |
| Set Point Tolerance | ±10 % of range |
| Override Options | Short Thermistor (Default); Field (Jumper) Selectable "Dry Contact" Closure (Separate Input); Short Set Point available upon request |
| Power Dissipation Constant | 3 mW / °C |
| Sensor Type | Thermistor |
| Connections | Screw Terminal Blocks |
| Terminal Block Torque Rating | 0.5 Nm minimum; 0.6 Nm maximum |
| Wire Size | 1.31 mm2 (16 AWG) to 0.129 mm2 (26 AWG) |
| Number Temperature Sensing Points | One Sensor Output at 25 °C (77 °F) |
| Operating Range | 1.5 °C to 50 °C (35 °F to 122 °F) |
| Sensor Curve | Non-Linear, NTC (Negative Temperature Coefficient) |
| Operating Humidity Range | 10 % to 95 % RH, non- condensing |
| Storage Temperature Range | -40 °C to 65 °C (-40 °F to 149 °F) |
| Enclosure Material | Color | "-R2" Enclosure: ABS Plastic, White, UL94-HB "-R" Enclosure: ABS Plastic, Beige UL94-HB |
| Product Dimensions (L x W x H) | 4.50 x 2.70 x 1.10" (114.3 x 68.6 x 27.9 mm) |
| Product Weight | 0.10 lbs (48 g) |
| Agency Approvals | CE**, UKCA, RoHS2, WEEE |