ACI A Series CO2 Duct Carbon Dioxide Transmitter, 0 to 2000 ppm, 0 to 10 V DC

Model: A/CO2-DUCT | Order No: 150117

ACI A Series CO2 Duct Carbon Dioxide Transmitter, 0 to 2000 ppm, 0 to 10 V DC

Model: A/CO2-DUCT | Order No: 150117

Ideal for demand control ventilation, this duct-mounted carbon dioxide transmitter measures 0 to 2000 ppm by single beam NDIR. In addition, outputs are 0 to 10 V DC and 4 to 20 mA, with 0-5 V DC field selectable on integral dip switches. Automatic baseline correction removes manual calibration in schools, offices and auditoriums.

Ideal for demand control ventilation, this duct-mounted carbon dioxide transmitter measures 0 to 2000 ppm by single beam NDIR. In addition, outputs are 0 to 10 V DC and 4 to 20 mA, with 0-5 V DC field selectable on integral dip switches. Automatic baseline correction removes manual calibration in schools, offices and auditoriums.

Sale Price $327.00 USD
Regular Price $557.00 USD
Availability 2 to 3 Weeks
Quantity

ACI A/CO2-DUCT Offers

The ACI Carbon Dioxide Duct Series (A/CO2-D) monitors the carbon dioxide (CO2) levels in industrial, commercial, school, and office-type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non-dispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide levels for building climate control.

In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default outputs are 0-10 V DC (Output 1) and 4-20 mA (Output 2), whereas 0-5 V DC is field selectable via integral dip switches. The A/CO2-D provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate.

Applications

  • Demand control ventilation in school and office buildings
  • Duct-mounted indoor air quality monitoring in air handling units
  • Return air CO2 monitoring for economizer and ventilation control
  • Auditorium and gymnasium ventilation control
  • Shopping mall and theatre air quality monitoring

ACI A/CO2-DUCT Specifications

Sensing Method Technology: Single beam infrared sensing technology (NDIR)
Method: Diffusion
Configuration Duct
Measurement Default range: 0 to 2000 ppm
Extended ranges: Up to 10,000 ppm (factory set)
Accuracy: ±40 ppm and ±3% of reading (at 15 to 35°C; 20 to 70% RH and 101.3 kPa)
Extended range accuracy above 2000 ppm: ±30 ppm and ±5% of reading
Pressure dependence: +1.6% reading per kPa (deviation from standard pressure 101.3 kPa)
Response time: ≤2 minutes, diffusion
Warm-up time: <1 Minute (at full specs <15 minutes)
Sensor Life and Calibration Sensor life: >15 years (typical)
Calibration: ABC algorithm (Automatic Baseline Correction)
Output CO2 output signal: Output 1: 0-5 V DC or 0-10 V DC (Default); Output 2: 4-20 mA (500 Ohm load maximum)
Fail safe: Polarity protected
Power Supply Supply voltage: 24 V AC ±20%, 50/60 Hz (half-wave rectifier) | 16.5 to 40 V DC maximum
Power consumption: 3 VA for 24 V AC, 3 W for 24 V DC (peak); <0.9 W (average)
Connections Type: Screw terminal blocks
Wire size: 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²)
Terminal block torque rating: 0.5 Nm (minimum); 0.6 Nm (maximum)
Housing Duct box: IP65 rated, PC & ABS blend, Flammability Rating UL94V-0
Cover: Makrolon® 6555 plastic, Flammability Rating UL94V-0
Pipe: PC & ABS blend, Flammability Rating UL94V-0
Operating Temperature Range 32 to 122°F (0 to 50°C)
Operating Humidity Range 0 to 95%, non-condensing
Agency Approvals EMC Directive 2014/30/EC | RoHS Directive 2011/65/EU
Dimensions 5.59 x 3.31 x 1.81" (142 x 84 x 46 mm)
Weight 0.79 lbs (0.36 kg)

What's included with the ACI A/CO2-DUCT

  • Sensor
  • Limited Five-Year Warranty

Ask a question about ACI A Series CO2 Duct Carbon Dioxide Transmitter, 0 to 2000 ppm, 0 to 10 V DC

Customer Reviews for the ACI A/CO2-DUCT

ACI A/CO2-DUCT Offers

The ACI Carbon Dioxide Duct Series (A/CO2-D) monitors the carbon dioxide (CO2) levels in industrial, commercial, school, and office-type environments. The concentration of CO2 is a strong indication of the overall indoor air quality. The A/CO2 Series is based on a single beam, non-dispersive infrared technology and is a cost-efficient solution for measuring carbon dioxide levels for building climate control.

In addition, ABC software eliminates the need for manual calibration. Carbon Dioxide concentration is measured up to 2,000 ppm and is converted into proportional analog outputs. The factory default outputs are 0-10 V DC (Output 1) and 4-20 mA (Output 2), whereas 0-5 V DC is field selectable via integral dip switches. The A/CO2-D provides data which can be used in conjunction with a Building Automation System or Demand Control Ventilation to decrease energy consumption while creating a healthier indoor climate.

Applications

  • Demand control ventilation in school and office buildings
  • Duct-mounted indoor air quality monitoring in air handling units
  • Return air CO2 monitoring for economizer and ventilation control
  • Auditorium and gymnasium ventilation control
  • Shopping mall and theatre air quality monitoring

ACI A/CO2-DUCT Specifications

Sensing Method Technology: Single beam infrared sensing technology (NDIR)
Method: Diffusion
Configuration Duct
Measurement Default range: 0 to 2000 ppm
Extended ranges: Up to 10,000 ppm (factory set)
Accuracy: ±40 ppm and ±3% of reading (at 15 to 35°C; 20 to 70% RH and 101.3 kPa)
Extended range accuracy above 2000 ppm: ±30 ppm and ±5% of reading
Pressure dependence: +1.6% reading per kPa (deviation from standard pressure 101.3 kPa)
Response time: ≤2 minutes, diffusion
Warm-up time: <1 Minute (at full specs <15 minutes)
Sensor Life and Calibration Sensor life: >15 years (typical)
Calibration: ABC algorithm (Automatic Baseline Correction)
Output CO2 output signal: Output 1: 0-5 V DC or 0-10 V DC (Default); Output 2: 4-20 mA (500 Ohm load maximum)
Fail safe: Polarity protected
Power Supply Supply voltage: 24 V AC ±20%, 50/60 Hz (half-wave rectifier) | 16.5 to 40 V DC maximum
Power consumption: 3 VA for 24 V AC, 3 W for 24 V DC (peak); <0.9 W (average)
Connections Type: Screw terminal blocks
Wire size: 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²)
Terminal block torque rating: 0.5 Nm (minimum); 0.6 Nm (maximum)
Housing Duct box: IP65 rated, PC & ABS blend, Flammability Rating UL94V-0
Cover: Makrolon® 6555 plastic, Flammability Rating UL94V-0
Pipe: PC & ABS blend, Flammability Rating UL94V-0
Operating Temperature Range 32 to 122°F (0 to 50°C)
Operating Humidity Range 0 to 95%, non-condensing
Agency Approvals EMC Directive 2014/30/EC | RoHS Directive 2011/65/EU
Dimensions 5.59 x 3.31 x 1.81" (142 x 84 x 46 mm)
Weight 0.79 lbs (0.36 kg)

What's included with the ACI A/CO2-DUCT

  • Sensor
  • Limited Five-Year Warranty