ACI A Series Thermistor Room Temperature Sensor, 10 kΩ type III, 0 Ω to 5 kΩ setpoint

Model: A/AN-R2SO-A16-C5 | Order No: 148743

ACI A Series Thermistor Room Temperature Sensor, 10 kΩ type III, 0 Ω to 5 kΩ setpoint

Model: A/AN-R2SO-A16-C5 | Order No: 148743

Ideal for space temperature monitoring, this room temperature sensor reads 35 to 122°F (1.5 to 50°C) behind a four-way air flow cover that limits self-heating. In addition, a 10 kΩ type III NTC thermistor pairs with a 0 Ω to 5 kΩ setpoint slidepot and an occupant override. It mounts over a single gang junction box in offices, classrooms and commercial zones.

Ideal for space temperature monitoring, this room temperature sensor reads 35 to 122°F (1.5 to 50°C) behind a four-way air flow cover that limits self-heating. In addition, a 10 kΩ type III NTC thermistor pairs with a 0 Ω to 5 kΩ setpoint slidepot and an occupant override. It mounts over a single gang junction box in offices, classrooms and commercial zones.

Sale Price $32.22 USD
Regular Price $83.00 USD
Availability 2 to 3 Weeks
Quantity

ACI A/AN-R2SO-A16-C5 Offers

The ACI Thermistor Room Series combines option flexibility with attractive styling in our “-R2” or “-R” style enclosures which include four-way air flow design to minimize self-heating to the sensor. These enclosures are offered in a White “-R2” or Beige “-R” color depending on the enclosure style. These units are designed to be mounted over a single gang junction box or hole in the wall using drywall anchors.

Screw terminal blocks are available for making all connections to your building management system (network). An optional 1/8" (3.175 mm) Black foam pad with pressure sensitive adhesive is available to insulate the sensor from thermal drafts within the wall or wall surface.

A 1/16" Hex driver is needed to secure the cover from being easily removed. The “LCD” option uses two temperature sensors to monitor the ambient air temperature in the space and is factory calibrated at a single point.

Applications

  • Space temperature sensing in offices and classrooms
  • Wall-mounted room temperature monitoring for building automation systems
  • Occupant setpoint adjustment in commercial zones
  • Decorative wall sensor installations in schools and colleges
  • OEM room temperature sensing in HVAC/R control panels

ACI A/AN-R2SO-A16-C5 Specifications

Sensor Type: Thermistor
Curve: Non-linear, NTC (Negative Temperature Coefficient)
Sensing points: One
Output at 77°F (25°C): 10 kΩ nominal (Type III)
Lead wire colors: White/white
Operating temperature range: 35 to 122°F (1.5 to 50°C)
Accuracy: ±0.36°F (±0.2°C), from 32 to 158°F (0 to 70°C)
Configuration Room with set point and override
Performance Stability: Sensor dependent; contact ACI for more information on specific sensor
Response time (63% step change): 10 seconds nominal
Power dissipation constant: 3 mW/°C
Connections Type: Screw terminal blocks
Wire size: 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²)
Terminal block torque rating: 0.5 Nm minimum; 0.6 Nm maximum
Enclosure Material: ABS plastic
Color: White
Flammability rating: UL94-HB
Set Point Range: 0 Ω to 5 kΩ (direct acting)
Tolerance: ±10% of range
Indication: COOL/WARM

Override options
Short thermistor (default)
Field (jumper) selectable "Dry Contact" closure (separate input)
Short set point (available upon request)
Environmental Conditions Storage temperature range: -40 to 149°F (-40 to 65°C)
Operating humidity range: 10 to 95% RH, non-condensing
Agency Approvals CE, UKCA, RoHS2, WEEE
Dimensions 2.75 x 4.50 x 1.12" (69.85 x 114.30 x 28.55 mm)
Weight 0.2 lbs (90.7 g)
Click here for complete specifications on the ACI A/AN-R2SO-A16-C5

What's included with the ACI A/AN-R2SO-A16-C5

  • 10 kΩ Type III Room Temperature Sensor
  • Jumper Shunts
  • Limited Five-Year Warranty

Ask a question about ACI A Series Thermistor Room Temperature Sensor, 10 kΩ type III, 0 Ω to 5 kΩ setpoint

Customer Reviews for the ACI A/AN-R2SO-A16-C5

ACI A/AN-R2SO-A16-C5 Offers

The ACI Thermistor Room Series combines option flexibility with attractive styling in our “-R2” or “-R” style enclosures which include four-way air flow design to minimize self-heating to the sensor. These enclosures are offered in a White “-R2” or Beige “-R” color depending on the enclosure style. These units are designed to be mounted over a single gang junction box or hole in the wall using drywall anchors.

Screw terminal blocks are available for making all connections to your building management system (network). An optional 1/8" (3.175 mm) Black foam pad with pressure sensitive adhesive is available to insulate the sensor from thermal drafts within the wall or wall surface.

A 1/16" Hex driver is needed to secure the cover from being easily removed. The “LCD” option uses two temperature sensors to monitor the ambient air temperature in the space and is factory calibrated at a single point.

Applications

  • Space temperature sensing in offices and classrooms
  • Wall-mounted room temperature monitoring for building automation systems
  • Occupant setpoint adjustment in commercial zones
  • Decorative wall sensor installations in schools and colleges
  • OEM room temperature sensing in HVAC/R control panels

ACI A/AN-R2SO-A16-C5 Specifications

Sensor Type: Thermistor
Curve: Non-linear, NTC (Negative Temperature Coefficient)
Sensing points: One
Output at 77°F (25°C): 10 kΩ nominal (Type III)
Lead wire colors: White/white
Operating temperature range: 35 to 122°F (1.5 to 50°C)
Accuracy: ±0.36°F (±0.2°C), from 32 to 158°F (0 to 70°C)
Configuration Room with set point and override
Performance Stability: Sensor dependent; contact ACI for more information on specific sensor
Response time (63% step change): 10 seconds nominal
Power dissipation constant: 3 mW/°C
Connections Type: Screw terminal blocks
Wire size: 16 AWG (1.31 mm²) to 26 AWG (0.129 mm²)
Terminal block torque rating: 0.5 Nm minimum; 0.6 Nm maximum
Enclosure Material: ABS plastic
Color: White
Flammability rating: UL94-HB
Set Point Range: 0 Ω to 5 kΩ (direct acting)
Tolerance: ±10% of range
Indication: COOL/WARM

Override options
Short thermistor (default)
Field (jumper) selectable "Dry Contact" closure (separate input)
Short set point (available upon request)
Environmental Conditions Storage temperature range: -40 to 149°F (-40 to 65°C)
Operating humidity range: 10 to 95% RH, non-condensing
Agency Approvals CE, UKCA, RoHS2, WEEE
Dimensions 2.75 x 4.50 x 1.12" (69.85 x 114.30 x 28.55 mm)
Weight 0.2 lbs (90.7 g)
Click here for complete specifications on the ACI A/AN-R2SO-A16-C5

What's included with the ACI A/AN-R2SO-A16-C5

  • 10 kΩ Type III Room Temperature Sensor
  • Jumper Shunts
  • Limited Five-Year Warranty

Ask a question about ACI A Series Thermistor Room Temperature Sensor, 10 kΩ type III, 0 Ω to 5 kΩ setpoint

Customer Reviews for the ACI A/AN-R2SO-A16-C5

More ACI Products