Measuring across a pump, chiller or coil, this wet differential pressure transmitter reads 0 to 30 psid through two stainless steel pressure ports rated for liquid service. A local LCD shows the differential without a service laptop. Metal-clad cables carry the sensors to the electronics, so the enclosure mounts away from the pipework it monitors and stays clear of the condensation that collects on a chilled line.
Measuring across a pump, chiller or coil, this wet differential pressure transmitter reads 0 to 30 psid through two stainless steel pressure ports rated for liquid service. A local LCD shows the differential without a service laptop. Metal-clad cables carry the sensors to the electronics, so the enclosure mounts away from the pipework it monitors and stays clear of the condensation that collects on a chilled line.
The ACI WPR2 Series is a remote wet-to-wet differential pressure transmitter built to cut installation time, often removing the need for extra plumbing and manifolds. The sensors sit at the taps and the electronics mount elsewhere, joined by cable rather than impulse tubing. Standard CMP-rated PVC cable is offered alongside a metal-clad option whose flexible conduit and 304 stainless steel construction resist abrasion, cuts and corrosion.
Features
Applications
| Pressure Range | 0 to 30 psid |
| Accuracy (Lowest Range) | ±1.5% FSO |
| Accuracy (Three Highest Ranges) | ±1.0% FSO |
| Output Load Resistance | 4 to 20 mA: 500 ohms maximum | 0 to 5 V DC / 0 to 10 V DC: 5K ohms minimum |
| Output Signals | 2-wire: Linear 4 to 20 mA DC current (Field Selectable) | 3-wire: 0 to 5 V DC; 0 to 10 V DC (Default) & 4 to 20 mA (Field Selectable) |
| Output Update Rate | 1 second |
| Supply Current | 4 to 20 mA Output: 24 mA minimum | 0 to 5 V DC / 0 to 10 V DC Outputs: 6 mA minimum |
| Supply Voltage | 4 to 20 mA output: 18 to 36 V DC (250 Ohm Load max.) / 20 to 36 V DC (500 Ohm Load max.) / 24 V AC (±10%) 50/60 Hz | 0 to 5 V DC and 0 to 10 V DC output: 16 to 36 V DC / 24 V AC (±10%) 50/60 Hz |
| Cable Length | 20' cables |
| Recommended Torque Specification | 150 lbs-in (16.95 Nm) Transducer Cable Rating | Connector Type CMP - Plenum Rated (UL Standard 444), NEC Article 800 | IP65 at the sensors Packard Connector |
| Burst Pressure | 300 PSI |
| Media Types | Any gas or liquid compatible w/ 304L or 316L Stainless Steel |
| Metal Clad Rating | Continuously interlocked Type 304 Stainless Steel core |
| Operating Humidity | 10 to 90% RH, non-condensing |
| Process Fitting Size | 1/4" - 18 NPT Male; Pressure Snubber included for light oils/water |
| Proof Pressure | 60 PSI |
| Thermal Effects | ±2.0% FSO from 32 to 140°F (0 to 60°C) |
| Warm Up Time | 15 minutes (wait 15 minutes before zeroing) |
| Compensated Temperature Range | 32 to 140°F (0 to 60°C) |
| Operating Temperature | Transducer: -40 to 257°F (-40 to 125°C) | Electronics/Housing/Cables: 32 to 167°F (0 to 75°C) |
| Storage Temperature | -13 to 176°F (-25 to 80°C) |
| Enclosure Material | Flammability Rating | Flame Retardant PC | PBT Alloy | UL94V-0 |
| Enclosure Rating | NEMA 4X/IP66 |
| Process Fitting Material | 304 SS |
| Product Dimensions (L x W x H) | 11.15 x 8.20 x 2.85" (283.2 x 208.3 x 72.4 mm) |
| Product Weight | 2.45 lbs (1112 g) |
| Approvals | CE, RoHS2, WEEE, Reach |
| Pressure Range | 0 to 30 psid |
| Accuracy (Lowest Range) | ±1.5% FSO |
| Accuracy (Three Highest Ranges) | ±1.0% FSO |
| Output Load Resistance | 4 to 20 mA: 500 ohms maximum | 0 to 5 V DC / 0 to 10 V DC: 5K ohms minimum |
| Output Signals | 2-wire: Linear 4 to 20 mA DC current (Field Selectable) | 3-wire: 0 to 5 V DC; 0 to 10 V DC (Default) & 4 to 20 mA (Field Selectable) |
| Output Update Rate | 1 second |
| Supply Current | 4 to 20 mA Output: 24 mA minimum | 0 to 5 V DC / 0 to 10 V DC Outputs: 6 mA minimum |
| Supply Voltage | 4 to 20 mA output: 18 to 36 V DC (250 Ohm Load max.) / 20 to 36 V DC (500 Ohm Load max.) / 24 V AC (±10%) 50/60 Hz | 0 to 5 V DC and 0 to 10 V DC output: 16 to 36 V DC / 24 V AC (±10%) 50/60 Hz |
| Cable Length | 20' cables |
| Recommended Torque Specification | 150 lbs-in (16.95 Nm) Transducer Cable Rating | Connector Type CMP - Plenum Rated (UL Standard 444), NEC Article 800 | IP65 at the sensors Packard Connector |
| Burst Pressure | 300 PSI |
| Media Types | Any gas or liquid compatible w/ 304L or 316L Stainless Steel |
| Metal Clad Rating | Continuously interlocked Type 304 Stainless Steel core |
| Operating Humidity | 10 to 90% RH, non-condensing |
| Process Fitting Size | 1/4" - 18 NPT Male; Pressure Snubber included for light oils/water |
| Proof Pressure | 60 PSI |
| Thermal Effects | ±2.0% FSO from 32 to 140°F (0 to 60°C) |
| Warm Up Time | 15 minutes (wait 15 minutes before zeroing) |
| Compensated Temperature Range | 32 to 140°F (0 to 60°C) |
| Operating Temperature | Transducer: -40 to 257°F (-40 to 125°C) | Electronics/Housing/Cables: 32 to 167°F (0 to 75°C) |
| Storage Temperature | -13 to 176°F (-25 to 80°C) |
| Enclosure Material | Flammability Rating | Flame Retardant PC | PBT Alloy | UL94V-0 |
| Enclosure Rating | NEMA 4X/IP66 |
| Process Fitting Material | 304 SS |
| Product Dimensions (L x W x H) | 11.15 x 8.20 x 2.85" (283.2 x 208.3 x 72.4 mm) |
| Product Weight | 2.45 lbs (1112 g) |
| Approvals | CE, RoHS2, WEEE, Reach |