ACI EPC Series Electronic to Pneumatic Transducer, dual valve

Model: EPC2 | Order No: 102476

ACI EPC Series Electronic to Pneumatic Transducer, dual valve

Model: EPC2 | Order No: 102476

Bridging a direct digital controller to a pneumatic actuator, this transducer converts a 0-5 V DC input into a 0-10 psi branch output. Dual valves hold branch pressure between corrections, so the transducer draws air only when the setpoint moves. It keeps an installed actuator in service under electronic control.

Bridging a direct digital controller to a pneumatic actuator, this transducer converts a 0-5 V DC input into a 0-10 psi branch output. Dual valves hold branch pressure between corrections, so the transducer draws air only when the setpoint moves. It keeps an installed actuator in service under electronic control.

Sale Price $213.01 USD
Regular Price $437.00 USD
Availability 2 to 3 Weeks
Quantity

ACI EPC2 Offers

The EPC Series are electric to pneumatic transducers which convert an analog input signal to a proportional pneumatic output, modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC series offers four selectable input ranges. Output pressure ranges are jumper shunt selectable and adjustable in all ranges. A feedback signal indicating the resultant branch line pressure is also provided.

Features

  • Bridges a direct digital controller to a pneumatic actuator
  • 0-5 V DC input to a 0-10 psi branch output
  • Dual valves hold branch pressure between corrections, so air is drawn only on a change

Applications

  • 3 way mixing valve control
  • Chiller loading
  • Pilot positioner control
  • Pneumatic valve & damper actuator control
  • Fan vane control
  • DDC control
  • Above ceiling applications (Mixing & VAV boxes)

ACI EPC2 Specifications

Output Pressure Range Field Calibration Possible: 0 to 20 psig (0 to 138 kPa) maximum
Output Pressure Accuracy | 1% room temperature 2% full scale across
Feedback Signal Output Range 0 to 5 V DC = Output Span
Input Signal Source (@ Impedance) 0 to 5 V DC @ infinite Ω | 0 to 10 V DC @ infinite Ω | 0 to 15 V DC @ infinite Ω | 0 to 20 mA / 250Ω
Output Supply valves @ 25 psig (172.38 kPa) main/20 psig (137.9 kPa) out, 2300 scim
Dry Contacts 24 V DC/VAC @ 1A maximum, N.O. in AUTO operation (Optional: N.O. in MAN operation)
Manual / Auto Override Switch MAN funciton = output can be varied | AUTO function = output is controlled from input signal Manual / Auto Override Feedback
Supply Current 500 mAAC, 200 mADC Maximum
Supply Voltage 24 V AC (± 10%), 50/60 Hz, 24 V DC (+10% / -5%)
Connections | Wire Size 90° Pluggable Screw Terminal Blocks | 16 (1.31 mm2) to 26 AWG (0.129 mm2)
Terminal Block Torque Rating 0.5 Nm (Minimum); 0.6 Nm (Maximum) Connections | Pneumatic Tubing Size- 1/4" O.D. nominal (1/8" I.D.) polyethylene
Air Flow Branch Line requires 2 in3 / 33.78 cm3 (min.) | Min. 25 ft of 1/4" O.D. poly branch tubing Furnished with integral-in-barb 80 to 100 micron filter (Part #PN004) except for EPC2LG which is furnished
Air Supply Pressure Maximum 25 psig (172.369 kPa), minimum 22 psig (151.69 kPa)
Filtering With external 5 micron in-line filter (PN021)
Pneumatic Fitting Removable brass fittings for Main & Branchc in machined manifold, Plugged 1/8-27-FNPT gauge port
Operating Humidity Range 10 to 95% non-condensing
Operating Temperature Range 35 to 120°F (1.7 to 48.9°C)
Storage Temperature Range -20 to 150°F (-28.9 to 65.5°C)
Enclosure Options (Box Options) Painted steel housing has mounting flange with four holes for sheet metal screws
Snaptrack Flammability Rating UL94 V-0
Snaptrack Material Polyvinyl Chloride (PVC)
Product Dimensions (L x W x H) 3.40 x 3.80 x 1.75" (86.4 x 96.5 x 44.4 mm)
Product Weight 0.46 lbs (208 g)
Agency Approvals RoHS2, WEEE
Click here for complete specifications on the ACI EPC2

What's included with the ACI EPC2

  • Electronic to Pneumatic Transducer
  • Two-Year Warranty

Ask a question about ACI EPC Series Electronic to Pneumatic Transducer, dual valve

Customer Reviews for the ACI EPC2

ACI EPC2 Offers

The EPC Series are electric to pneumatic transducers which convert an analog input signal to a proportional pneumatic output, modulating its control valve(s) to regulate the branch line pressure to the set point determined by the input signal. The EPC series offers four selectable input ranges. Output pressure ranges are jumper shunt selectable and adjustable in all ranges. A feedback signal indicating the resultant branch line pressure is also provided.

Features

  • Bridges a direct digital controller to a pneumatic actuator
  • 0-5 V DC input to a 0-10 psi branch output
  • Dual valves hold branch pressure between corrections, so air is drawn only on a change

Applications

  • 3 way mixing valve control
  • Chiller loading
  • Pilot positioner control
  • Pneumatic valve & damper actuator control
  • Fan vane control
  • DDC control
  • Above ceiling applications (Mixing & VAV boxes)

ACI EPC2 Specifications

Output Pressure Range Field Calibration Possible: 0 to 20 psig (0 to 138 kPa) maximum
Output Pressure Accuracy | 1% room temperature 2% full scale across
Feedback Signal Output Range 0 to 5 V DC = Output Span
Input Signal Source (@ Impedance) 0 to 5 V DC @ infinite Ω | 0 to 10 V DC @ infinite Ω | 0 to 15 V DC @ infinite Ω | 0 to 20 mA / 250Ω
Output Supply valves @ 25 psig (172.38 kPa) main/20 psig (137.9 kPa) out, 2300 scim
Dry Contacts 24 V DC/VAC @ 1A maximum, N.O. in AUTO operation (Optional: N.O. in MAN operation)
Manual / Auto Override Switch MAN funciton = output can be varied | AUTO function = output is controlled from input signal Manual / Auto Override Feedback
Supply Current 500 mAAC, 200 mADC Maximum
Supply Voltage 24 V AC (± 10%), 50/60 Hz, 24 V DC (+10% / -5%)
Connections | Wire Size 90° Pluggable Screw Terminal Blocks | 16 (1.31 mm2) to 26 AWG (0.129 mm2)
Terminal Block Torque Rating 0.5 Nm (Minimum); 0.6 Nm (Maximum) Connections | Pneumatic Tubing Size- 1/4" O.D. nominal (1/8" I.D.) polyethylene
Air Flow Branch Line requires 2 in3 / 33.78 cm3 (min.) | Min. 25 ft of 1/4" O.D. poly branch tubing Furnished with integral-in-barb 80 to 100 micron filter (Part #PN004) except for EPC2LG which is furnished
Air Supply Pressure Maximum 25 psig (172.369 kPa), minimum 22 psig (151.69 kPa)
Filtering With external 5 micron in-line filter (PN021)
Pneumatic Fitting Removable brass fittings for Main & Branchc in machined manifold, Plugged 1/8-27-FNPT gauge port
Operating Humidity Range 10 to 95% non-condensing
Operating Temperature Range 35 to 120°F (1.7 to 48.9°C)
Storage Temperature Range -20 to 150°F (-28.9 to 65.5°C)
Enclosure Options (Box Options) Painted steel housing has mounting flange with four holes for sheet metal screws
Snaptrack Flammability Rating UL94 V-0
Snaptrack Material Polyvinyl Chloride (PVC)
Product Dimensions (L x W x H) 3.40 x 3.80 x 1.75" (86.4 x 96.5 x 44.4 mm)
Product Weight 0.46 lbs (208 g)
Agency Approvals RoHS2, WEEE
Click here for complete specifications on the ACI EPC2

What's included with the ACI EPC2

  • Electronic to Pneumatic Transducer
  • Two-Year Warranty

Ask a question about ACI EPC Series Electronic to Pneumatic Transducer, dual valve