ACR 01-0091 SmartReader Plus 4

Model: ACR 01-0091 | Order No: 01-0091

ACR 01-0091 SmartReader Plus 4

Model: ACR 01-0091 | Order No: 01-0091

Four channel temperature, pressure, and humidity data logger.

Four channel temperature, pressure, and humidity data logger.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

ACR 01-0115 SmartReader Plus 4 Data Logger-

ACR 01-0115 SmartReader Plus 4 Data Logger

Model: ACR 01-0115 | Order No: 01-0115

Allows users to easily monitor and troubleshoot pneumatic control systems. Additionally, this data logger is self-contained and features a ¼" quick release pressure fitting which allows a fast and trouble-free connection.


SmartReader Plus 4 Four Channel - 32KB Pressure, Temperature and Relative Humidity Data Logger

The SmartReader Plus 4 data logger provides easy monitoring and troubleshooting of pneumatic control systems. The unit is completely self-contained with a ¼" quick-release pressure fitting to allow a fast and trouble-free connection. As an added bonus, the SmartReader Plus 4 also monitors ambient temperature and either external temperature (with thermistor probes) or temperature and relative humidity together (with an RH/temperature probe). Probes and sensors are sold separately.


Features:

  • Four channels
  • Monitor pressure, temperature and RH
  • Choose from a variety of different pressure ranges
  • Use with a variety of different temperature probes

Applications:

  • Performance tracking of pneumatically controlled valves
  • Verifying thermostat and humidistats
  • Monitoring sensitive shipments

Specifications:

GENERAL SPECIFICATIONS
Model Pressure Range Memory Catalog Number
SRP-003-128 0-10" H2O 32 KB 01-0090
SRP-004-010-128K 0-10" H2O 128 KB 01-0120
SRP-004-5G 0-5 PSI-G 32 KB 01-0091
SRP-004-5G-128K 0-5 PSI-G 128 KB 01-0115
SRP-004-30G 0-30 PSI-G 32 KB 01-0093
SRP-004-30G-128K 0-30 PSI-G 128 KB 01-0117
SRP-004-30A 0-30 PSI-A 32 KB 01-0092
SRP-004-30A-128K 0-30 PSI-A 128 KB 01-0116
SRP-004-100G 0-100 PSI-G 32 KB 01-0095
SRP-004-100G-128K 0-100 PSI-G 128 KB 01-0119
SRP-004-100A 0-100 PSI-A 32 KB 01-0094
SRP-004-100A-128K 0-100 PSI-A 128 KB 01-0118
SRP-004-150G 0-150 PSI-G 32 KB 01-0097
SRP-004-150G-128K 0-150 PSI-G 128 KB 01-0139
 
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium
Resolution 12-bit (1 part in 4096)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
*Not available with sample rates faster than eight seconds.
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
Memory Size
(2 memory sizes available)
32 KB (capable of storing up to 21,500 readings)
128 KB (capable of storing up to 87,000 readings)
Sampling Rates User selectable rates from 25 per second to once every eight hours
(BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
Number of Channels Four (4):
  • One (1) internal sensor for ambient temperature
  • One (1) for pressure
  • Two (2) for optional remote relative humidity and temperature probe [model EH-020A]
Click here for complete specifications on the ACR ACR 01-0091

What's included with the ACR ACR 01-0091

  • ACR 01-0091 SmartReader Plus 4

Click on a category to view a selection of compatible accessories with the ACR 01-0091 SmartReader Plus 4.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 29-0013 Terminal Block Strain Relief ACR 29-0013
Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks.




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 35-0000 Therm Penetration Probe - Low Temp ACR 35-0000
Stainless steel, 3 1/2in penetration probe w/handle. Thermistor type. Range: -60 to 55°C (-75 to 130°F). Length: 10ft (3 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.




Ask a question about ACR 01-0091 SmartReader Plus 4

Customer Reviews for the ACR ACR 01-0091

SmartReader Plus 4 Four Channel - 32KB Pressure, Temperature and Relative Humidity Data Logger

The SmartReader Plus 4 data logger provides easy monitoring and troubleshooting of pneumatic control systems. The unit is completely self-contained with a ¼" quick-release pressure fitting to allow a fast and trouble-free connection. As an added bonus, the SmartReader Plus 4 also monitors ambient temperature and either external temperature (with thermistor probes) or temperature and relative humidity together (with an RH/temperature probe). Probes and sensors are sold separately.


Features:

  • Four channels
  • Monitor pressure, temperature and RH
  • Choose from a variety of different pressure ranges
  • Use with a variety of different temperature probes

Applications:

  • Performance tracking of pneumatically controlled valves
  • Verifying thermostat and humidistats
  • Monitoring sensitive shipments

Specifications:

GENERAL SPECIFICATIONS
Model Pressure Range Memory Catalog Number
SRP-003-128 0-10" H2O 32 KB 01-0090
SRP-004-010-128K 0-10" H2O 128 KB 01-0120
SRP-004-5G 0-5 PSI-G 32 KB 01-0091
SRP-004-5G-128K 0-5 PSI-G 128 KB 01-0115
SRP-004-30G 0-30 PSI-G 32 KB 01-0093
SRP-004-30G-128K 0-30 PSI-G 128 KB 01-0117
SRP-004-30A 0-30 PSI-A 32 KB 01-0092
SRP-004-30A-128K 0-30 PSI-A 128 KB 01-0116
SRP-004-100G 0-100 PSI-G 32 KB 01-0095
SRP-004-100G-128K 0-100 PSI-G 128 KB 01-0119
SRP-004-100A 0-100 PSI-A 32 KB 01-0094
SRP-004-100A-128K 0-100 PSI-A 128 KB 01-0118
SRP-004-150G 0-150 PSI-G 32 KB 01-0097
SRP-004-150G-128K 0-150 PSI-G 128 KB 01-0139
 
Size 107mm x 74mm x 22mm (4.2" x 2.9" x 0.9")
Weight 110 g (3.75 oz)
Case Material Noryl® Plastic
Battery 3.6 volt Lithium
Resolution 12-bit (1 part in 4096)
Mounting Magnetic backing or locking eyelet
Clock Accuracy ± 2 seconds per day
Sampling Methods Continuous (First-in First-out), Stop When Full (Fill-then-stop)
*Not available with sample rates faster than eight seconds.
Operating Limits -40°C to 70°C (-40°F to 158°F) and 0 to 95% RH (non-condensing)
PC Requirements Windows PC with at least one free USB or serial port (depending on interface)
Software Requirements TrendReader® 2 (Compatible with Windows 2000 SP4, XP SP1 and Vista 32 bit)
Memory Size
(2 memory sizes available)
32 KB (capable of storing up to 21,500 readings)
128 KB (capable of storing up to 87,000 readings)
Sampling Rates User selectable rates from 25 per second to once every eight hours
(BP-101 battery pack or PS-201 power supply required for sampling rates faster than eight seconds)
Number of Channels Four (4):
  • One (1) internal sensor for ambient temperature
  • One (1) for pressure
  • Two (2) for optional remote relative humidity and temperature probe [model EH-020A]
Click here for complete specifications on the ACR ACR 01-0091

What's included with the ACR ACR 01-0091

  • ACR 01-0091 SmartReader Plus 4

Click on a category to view a selection of compatible accessories with the ACR 01-0091 SmartReader Plus 4.

ACR Fast Sampling Battery Pack BP-101 ACR 01-0078
Portable power supply for SmartReader Plus data loggers to allow them to sample faster than 8 seconds.




ACR 29-0013 Terminal Block Strain Relief ACR 29-0013
Strain relief for sensors attached to SmartReader/SmartReader Plus 11-pin terminal blocks.




ACR 01-0171 SmartReader Plus Display Module ACR 01-0171
Portable Real-time Display Module for any SmartReader Plus Data Logger (2 AA batteries and 1 foot cable included).




ACR 01-0098 Network Y Splitter - Stereo (YA-200) ACR 01-0098
Allows a SmartReader Plus logger to be added to an ACR-stereo type network. 1 male and 2 female ends. Includes 1ft male to male adapter cable.




ACR 01-0167 Alarm Module - 100 - NA ACR 01-0167
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 120V NA power supply for SmartReader Plus loggers.




ACR 01-0168 Alarm Module - 100 - EU ACR 01-0168
Alarm module, stereo Y-adapter, 1ft male-male stereo cable, and 240V Cont. Europe power supply for SmartReader Plus loggers.




ACR 35-0000 Therm Penetration Probe - Low Temp ACR 35-0000
Stainless steel, 3 1/2in penetration probe w/handle. Thermistor type. Range: -60 to 55°C (-75 to 130°F). Length: 10ft (3 meters).




ACR 35-0001 Thermal Probe - General Purpose Temperature ACR 35-0001
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 35-0002 Therm-Probe - GP Tip - 80C - SR SRP ACR 35-0002
Stainless Steel, 1 X 3/16in probe. Thermistor type. Range: 10 to 170°C (50 to 335°F). Length: 20ft (6 meters).




ACR 35-0003 Thermal Probe - Oven Temperature ACR 35-0003
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: 70 to 255°C (155 to 490°F). Length: 20ft (6 meters).




ACR 35-0020 Skin Surface Thermal Probe - Human Temperature ACR 35-0020
Stainless steel, 1/3 X 9/64in probe. Thermistor type. Range: 20 to 40°C (68 to 104°F). Length: 5ft (1.5 meters).




ACR 35-0025 Pipe Surface Thermal Probe - General Purpose ACR 35-0025
Stainless steel, 1 X 3/16in probe. Thermistor type. Range: -35 to 95°C (-30 to 200°F). Length: 20ft (6 meters).




ACR 01-0165 Net Fast Sample Power Supply - 120V N A ACR 01-0165
120V AC to 5V DC power supply for SmartReader Plus networks with a minimum of three loggers or >50ft of network cable. Includes inYin splitter (YA-200).




ACR 01-0057 Weatherproof Logger Box ACR 01-0057
NEMA 4X clear-faced weatherproof box for all ACR loggers, Size: 18 x 13 x 10cm (7 x 5 x 4").




ACR 01-0077 Logger-PC Interface Cable (IC-101) ACR 01-0077
9-pin PC serial port to logger interface cable. Compatible with SmartReader and SmartReader Plus loggers.




ACR 01-0088 Logger-PC Interface Cable, 4' ACR 01-0088
Connect the SmartReader Plus data logger to PC computer through a USB port with this interface cable which measures 4' (1.22 m). In addition, this interface cable has a 0.138" (3.5 mm) stereo jack connection.




ACR 29-0004 Terminal Block - 11 Pin ACR 29-0004
11-pin female teminal block for SmartReader/SmartReader Plus sensor inputs.