Additel ADT282 Reference Thermometer, 14 to 122°F, 0 to 95% RH, dual-channel

Model: ADT282

Additel ADT282 Reference Thermometer, 14 to 122°F, 0 to 95% RH, dual-channel

Model: ADT282

This reference thermometer makes temperature measurements simple, with an operating temperature of 14 to 122°F (10 to 50°C), and humidity of 0 to 95% RH. This includes dual inputs providing support for a multitude of resistive type sensors and thermocouples.

This reference thermometer makes temperature measurements simple, with an operating temperature of 14 to 122°F (10 to 50°C), and humidity of 0 to 95% RH. This includes dual inputs providing support for a multitude of resistive type sensors and thermocouples.

Your Price $3459.00 USD
Availability 2 to 3 Weeks
Quantity

Additel ADT282 Offers

Additel’s 282 Reference Thermometer Readout delivers the best possible accuracies and features in the palm of your hand! With accuracy capabilities on par with laboratory grade thermometers, the ADT282 is capable of handling even your most critical measurements. This ultra-high precision readout features dual analog channels designed to facilitate comparison measurements and meet all of your temperature measurement needs. The easy to use touchscreen makes navigating the well-designed menus a time saving and enjoyable experience. The Lemo style smart connectors help to ensure that your probe calibration information is never in question. The ADT282 Reference Thermometer Readout helps makes metrology simple and will quickly become your new go-to when reliable temperature measurements are a must.

Features

  • Accuracy to 0.006°C at 0°C
  • Dual measurement channels
  • RTD and TC inputs
  • Smart style probe connections
  • Large smartphone like touchscreen
  • Differential measurement technology
  • Bluetooth and USB communications
  • Built-in sensor library
  • Datalogging
  • IP67 rated
  • Rugged handheld construction
  • Rechargeable lithium battery

Additel ADT282 Specifications

Measurement
PRT Measurement RTD Types: ITS-90, CVD, Ohms, Pt100 (385), Pt10 (385), Pt25 (385), Pt50 (385), Pt100 (3916), Pt100 (3926), Pt100 (391), Cu100 (428), Cu50 (428), Cu10 (427), Ni100 (617), Ni100 (618), Ni120 (672), and custom RTD
Resistance Accuracy: 0~ to 400Ω: ±0.5mΩ at (0 to 20Ω), ±25ppm RD at (20 to 400Ω)
Measurement range: -328 to 1562°F (-200 to 850°C)
Resolution: ±0.1mΩ or 0.0018°F (0.001°C)
Connection Type: 4-wire smart connection
Excitation Current: 1 mA - alternating constant current
Temperature Coefficient: ±1.1 ppm FS/°F (±2 ppm FS/°C) (-10°C~10°C and 30°C~50°C)
TC Measurement TC Types: mV, S, R, B, K, N, E, J, T, C, D, G, L, U, LR, A, 5.6uV/°F (10uV/°C), 0.56mV/°F (1mV/°C), Standard TC
Electrical Measurement: -10 to 75mV: ±(50ppm RD+2uV)
TC measurement range: -454 to 3272°F (-270 to 1800°C)
Resolution: ±0.1uV or 0.0018°F (0.001°C)
Connection Type: Mini-TC
CJC compensation methods: Internal, external or manual entry
Temperature Coefficient: ±2.8 ppm FS/°F (±5 ppm FS/°C) (-10°C~10°C and 30°C~50°C)
Internal CJC Specification: ±0.27°F (±0.15°C) (-10 to 50°C)
General
Display 5.0" 480 x 800 TFT LCD capacitive screen
Power Supply 6600mAh, 23.8Wh lithium battery, charging time 4 to 6 hours, battery pack can be charged independent. Battery life typically 16 hours
Environment Specification guaranteed temperature range: 50 to 86°F (10 to 30°C)
Working Temperature: 14 to 122°F (10 to 50°C)
Storage temperature: -4 to 158°F (-20 to 70°C)
Humidity: 0 to 95% RH, non-condensing
Warm-Up Time 10 minutes
Ports Protection Voltage 50V max
CE Certificate TUV IEC61326, IEC61010
Rohs Compliance Rohs II Directive 2011/65/EU, EN50581:2012
IP Protection Level IP67, 3.28' (1 m) drop test
Communication Isolate USB-TypeC (slave), Bluetooth BLE
Input Channels CH1, CH2 analog channel, 6 pins smart lemo ports for RTD probe; MINI-TC ports for TC probe
Measurement Display Single channel, dual channel, differential (e.g T1-T2)
Measuring Rates CH1, CH2 analog channels alternately and cyclically measure
RTD measuring rate: 1.6S/single channel, 1.6S/dual channel
TC measuring rate: 0.8S/single channel, 0.8S/dual channel
Measurement Units °C, °F, K
Statistics Max, Min, Avg
Warranty 1 Year
Dimension 6.97 x 4.13 x 2.04" (177 x 105 x 52 mm)
Weight 1.5 lbs (0.65 kg)
Click here for complete specifications on the Additel ADT282

What's included with the Additel ADT282

  • Reference Thermometer
  • ISO 17025 Accredited Calibration Certificate
  • USB Cable Type A to Type C
  • Power Adapter
  • Chargeable Li-Ion Battery
  • One-Year Warranty

Ask a question about Additel ADT282 Reference Thermometer, 14 to 122°F, 0 to 95% RH, dual-channel

Customer Reviews for the Additel ADT282

Additel ADT282 Offers

Additel’s 282 Reference Thermometer Readout delivers the best possible accuracies and features in the palm of your hand! With accuracy capabilities on par with laboratory grade thermometers, the ADT282 is capable of handling even your most critical measurements. This ultra-high precision readout features dual analog channels designed to facilitate comparison measurements and meet all of your temperature measurement needs. The easy to use touchscreen makes navigating the well-designed menus a time saving and enjoyable experience. The Lemo style smart connectors help to ensure that your probe calibration information is never in question. The ADT282 Reference Thermometer Readout helps makes metrology simple and will quickly become your new go-to when reliable temperature measurements are a must.

Features

  • Accuracy to 0.006°C at 0°C
  • Dual measurement channels
  • RTD and TC inputs
  • Smart style probe connections
  • Large smartphone like touchscreen
  • Differential measurement technology
  • Bluetooth and USB communications
  • Built-in sensor library
  • Datalogging
  • IP67 rated
  • Rugged handheld construction
  • Rechargeable lithium battery

Additel ADT282 Specifications

Measurement
PRT Measurement RTD Types: ITS-90, CVD, Ohms, Pt100 (385), Pt10 (385), Pt25 (385), Pt50 (385), Pt100 (3916), Pt100 (3926), Pt100 (391), Cu100 (428), Cu50 (428), Cu10 (427), Ni100 (617), Ni100 (618), Ni120 (672), and custom RTD
Resistance Accuracy: 0~ to 400Ω: ±0.5mΩ at (0 to 20Ω), ±25ppm RD at (20 to 400Ω)
Measurement range: -328 to 1562°F (-200 to 850°C)
Resolution: ±0.1mΩ or 0.0018°F (0.001°C)
Connection Type: 4-wire smart connection
Excitation Current: 1 mA - alternating constant current
Temperature Coefficient: ±1.1 ppm FS/°F (±2 ppm FS/°C) (-10°C~10°C and 30°C~50°C)
TC Measurement TC Types: mV, S, R, B, K, N, E, J, T, C, D, G, L, U, LR, A, 5.6uV/°F (10uV/°C), 0.56mV/°F (1mV/°C), Standard TC
Electrical Measurement: -10 to 75mV: ±(50ppm RD+2uV)
TC measurement range: -454 to 3272°F (-270 to 1800°C)
Resolution: ±0.1uV or 0.0018°F (0.001°C)
Connection Type: Mini-TC
CJC compensation methods: Internal, external or manual entry
Temperature Coefficient: ±2.8 ppm FS/°F (±5 ppm FS/°C) (-10°C~10°C and 30°C~50°C)
Internal CJC Specification: ±0.27°F (±0.15°C) (-10 to 50°C)
General
Display 5.0" 480 x 800 TFT LCD capacitive screen
Power Supply 6600mAh, 23.8Wh lithium battery, charging time 4 to 6 hours, battery pack can be charged independent. Battery life typically 16 hours
Environment Specification guaranteed temperature range: 50 to 86°F (10 to 30°C)
Working Temperature: 14 to 122°F (10 to 50°C)
Storage temperature: -4 to 158°F (-20 to 70°C)
Humidity: 0 to 95% RH, non-condensing
Warm-Up Time 10 minutes
Ports Protection Voltage 50V max
CE Certificate TUV IEC61326, IEC61010
Rohs Compliance Rohs II Directive 2011/65/EU, EN50581:2012
IP Protection Level IP67, 3.28' (1 m) drop test
Communication Isolate USB-TypeC (slave), Bluetooth BLE
Input Channels CH1, CH2 analog channel, 6 pins smart lemo ports for RTD probe; MINI-TC ports for TC probe
Measurement Display Single channel, dual channel, differential (e.g T1-T2)
Measuring Rates CH1, CH2 analog channels alternately and cyclically measure
RTD measuring rate: 1.6S/single channel, 1.6S/dual channel
TC measuring rate: 0.8S/single channel, 0.8S/dual channel
Measurement Units °C, °F, K
Statistics Max, Min, Avg
Warranty 1 Year
Dimension 6.97 x 4.13 x 2.04" (177 x 105 x 52 mm)
Weight 1.5 lbs (0.65 kg)
Click here for complete specifications on the Additel ADT282

What's included with the Additel ADT282

  • Reference Thermometer
  • ISO 17025 Accredited Calibration Certificate
  • USB Cable Type A to Type C
  • Power Adapter
  • Chargeable Li-Ion Battery
  • One-Year Warranty

Ask a question about Additel ADT282 Reference Thermometer, 14 to 122°F, 0 to 95% RH, dual-channel

Customer Reviews for the Additel ADT282

More Additel Products