Bringing a repeatable temperature source to the plant floor, this dry well calibrator spans -40 to 155°C, holds ±0.18°C across the full range, and reaches 155°C in 13 minutes. Insert E sets the hole pattern in the well. Process electronics read a reference probe and two devices under test, drive HART transmitters and log results as found and as left.
Bringing a repeatable temperature source to the plant floor, this dry well calibrator spans -40 to 155°C, holds ±0.18°C across the full range, and reaches 155°C in 13 minutes. Insert E sets the hole pattern in the well. Process electronics read a reference probe and two devices under test, drive HART transmitters and log results as found and as left.
Features
Applications
| Temperature Performance | |
| Temperature Range at 23°C | -40 to 155°C |
| Display Accuracy | ±0.18°C at full range |
| Stability | ±0.01°C at full range |
| Axial Uniformity at 60 mm (2.4") | ±0.07°C at full range |
| Radial Uniformity | ±0.01°C at full range |
| Loading Effect | ±0.1°C display sensor, ±0.02°C external sensor |
| Hysteresis | 0.025°C (display sensor) |
| Resolution | 0.01°C |
| Temperature Units | °C, °F and K |
| Heating Time | 13 minutes from -40 to 155°C, 5 minutes from -40 to 23°C, 8 minutes from 23 to 155°C |
| Cooling Time | 28 minutes from 155 to -40°C, 8 minutes from 155 to 23°C, 20 minutes from 23 to -40°C |
| Typical Time to Stability | 10 minutes |
| Well and Insert | |
| Immersion Depth | 5.70" (145 mm) |
| Insert Outside Diameter | 1.02" (25.8 mm) |
| Insert Supplied | ADT110-875-L-INSERT-E |
| Process Calibrator | |
| Reference Probe Input | 6-pin Lemo smart connector, 4-wire PRT |
| Reference Readout Accuracy | ±0.009°C at -40°C, ±0.017°C at 155°C, ±0.030°C at 420°C, ±0.042°C at 660°C |
| Reference Resistance Range | 0 to 400 Ω |
| Reference Resistance Accuracy | ±0.002 Ω from 0 to 50 Ω, ±40 ppm of reading from 50 to 400 Ω |
| Reference Characterizations | ITS-90, CVD, IEC-751, resistance |
| RTD Channels | 2, each accepting 2, 3 or 4-wire RTDs |
| RTD Measurement Accuracy | ±0.002 Ω from 0 to 25 Ω, ±0.008% of reading from 25 Ω to 4 kΩ |
| RTD Characterizations | PT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120 |
| Thermocouple Channels | 2, mini TC terminals accepting S, R, K, B, N, E, J, T, C, D, G, L and U |
| Thermocouple Accuracy, Type K | ±0.13°C at 0°C, ±0.16°C at 155°C, ±0.19°C at 350°C, ±0.25°C at 660°C |
| Thermocouple Range | -75 to 75 mV |
| Thermocouple Voltage Accuracy | 0.02% of reading + 5 µV |
| Internal Cold Junction Accuracy | ±0.35°C from 0 to 50°C ambient |
| Current Range | -30 to 30 mA |
| Current Accuracy | 0.02% of reading + 2 µA |
| Voltage Ranges | -12 to 12 V and -30 to 30 V |
| Voltage Accuracy | ±0.02% of reading + 2 mV |
| Switch Test | Mechanical or electrical |
| Loop Power Output | 24 V ±10%, 60 mA maximum |
| HART Communication | Read, configure and calibrate HART devices |
| Documentation | Up to 1000 tasks storing 10 results each, with as-found and as-left data |
| General | |
| Display | 6.5" (165 mm) color touch screen |
| Communication | USB-A, USB-B, RJ45, Wi-Fi, Bluetooth |
| Dimensions | 12.6 x 6.7 x 13.0" (320 x 170 x 330 mm) |
| Weight | 21.8 lb (9.9 kg) |
| Power Requirements | 90 to 254 V AC, 45 to 65 Hz, 580 W |
| Environmental Conditions | 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m |
| Storage Conditions | -20 to 60°C |
| Mechanical Testing | Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm) |
Click on a category to view a selection of compatible accessories with the Additel ADT875PC-155-E-110V Dry Well Calibrator with Process Calibrator, -40 to 155°C, insert E, 110V.
| Temperature Performance | |
| Temperature Range at 23°C | -40 to 155°C |
| Display Accuracy | ±0.18°C at full range |
| Stability | ±0.01°C at full range |
| Axial Uniformity at 60 mm (2.4") | ±0.07°C at full range |
| Radial Uniformity | ±0.01°C at full range |
| Loading Effect | ±0.1°C display sensor, ±0.02°C external sensor |
| Hysteresis | 0.025°C (display sensor) |
| Resolution | 0.01°C |
| Temperature Units | °C, °F and K |
| Heating Time | 13 minutes from -40 to 155°C, 5 minutes from -40 to 23°C, 8 minutes from 23 to 155°C |
| Cooling Time | 28 minutes from 155 to -40°C, 8 minutes from 155 to 23°C, 20 minutes from 23 to -40°C |
| Typical Time to Stability | 10 minutes |
| Well and Insert | |
| Immersion Depth | 5.70" (145 mm) |
| Insert Outside Diameter | 1.02" (25.8 mm) |
| Insert Supplied | ADT110-875-L-INSERT-E |
| Process Calibrator | |
| Reference Probe Input | 6-pin Lemo smart connector, 4-wire PRT |
| Reference Readout Accuracy | ±0.009°C at -40°C, ±0.017°C at 155°C, ±0.030°C at 420°C, ±0.042°C at 660°C |
| Reference Resistance Range | 0 to 400 Ω |
| Reference Resistance Accuracy | ±0.002 Ω from 0 to 50 Ω, ±40 ppm of reading from 50 to 400 Ω |
| Reference Characterizations | ITS-90, CVD, IEC-751, resistance |
| RTD Channels | 2, each accepting 2, 3 or 4-wire RTDs |
| RTD Measurement Accuracy | ±0.002 Ω from 0 to 25 Ω, ±0.008% of reading from 25 Ω to 4 kΩ |
| RTD Characterizations | PT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120 |
| Thermocouple Channels | 2, mini TC terminals accepting S, R, K, B, N, E, J, T, C, D, G, L and U |
| Thermocouple Accuracy, Type K | ±0.13°C at 0°C, ±0.16°C at 155°C, ±0.19°C at 350°C, ±0.25°C at 660°C |
| Thermocouple Range | -75 to 75 mV |
| Thermocouple Voltage Accuracy | 0.02% of reading + 5 µV |
| Internal Cold Junction Accuracy | ±0.35°C from 0 to 50°C ambient |
| Current Range | -30 to 30 mA |
| Current Accuracy | 0.02% of reading + 2 µA |
| Voltage Ranges | -12 to 12 V and -30 to 30 V |
| Voltage Accuracy | ±0.02% of reading + 2 mV |
| Switch Test | Mechanical or electrical |
| Loop Power Output | 24 V ±10%, 60 mA maximum |
| HART Communication | Read, configure and calibrate HART devices |
| Documentation | Up to 1000 tasks storing 10 results each, with as-found and as-left data |
| General | |
| Display | 6.5" (165 mm) color touch screen |
| Communication | USB-A, USB-B, RJ45, Wi-Fi, Bluetooth |
| Dimensions | 12.6 x 6.7 x 13.0" (320 x 170 x 330 mm) |
| Weight | 21.8 lb (9.9 kg) |
| Power Requirements | 90 to 254 V AC, 45 to 65 Hz, 580 W |
| Environmental Conditions | 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m |
| Storage Conditions | -20 to 60°C |
| Mechanical Testing | Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm) |
Click on a category to view a selection of compatible accessories with the Additel ADT875PC-155-E-110V Dry Well Calibrator with Process Calibrator, -40 to 155°C, insert E, 110V.