Calibrating noble-metal thermocouples to reference accuracy, this reference calibration furnace spans 100 to 1210°C, displays within ±1.0°C to 600°C and ±1.5°C at 1210°C, and reaches 1210°C in 50 minutes. No insert ships, so you choose the hole pattern. Process electronics read a reference probe and four devices under test, drive HART transmitters and log results as found and as left.
Calibrating noble-metal thermocouples to reference accuracy, this reference calibration furnace spans 100 to 1210°C, displays within ±1.0°C to 600°C and ±1.5°C at 1210°C, and reaches 1210°C in 50 minutes. No insert ships, so you choose the hole pattern. Process electronics read a reference probe and four devices under test, drive HART transmitters and log results as found and as left.
Features
Applications
| Temperature Performance | |
| Temperature Range at 23°C | 100 to 1210°C |
| Display Accuracy | ±1.0°C at 100°C, ±1.0°C at 300°C, ±1.0°C at 600°C, ±1.2°C at 900°C, ±1.5°C at 1210°C |
| Stability | ±0.1°C |
| Axial Uniformity at 60 mm (2.4") | ±0.4°C at 100°C, ±0.8°C at 300°C, ±1.0°C at 600°C, ±1.0°C at 900°C, ±1.0°C at 1210°C |
| Radial Uniformity | ±0.2°C at 100°C, ±0.3°C at 300°C, ±0.4°C at 600°C, ±0.6°C at 900°C, ±0.8°C at 1210°C |
| Loading Effect | ±0.5°C |
| Resolution | 0.01°C |
| Temperature Units | °C, °F and K |
| Heating Time | 50 minutes from 23 to 1210°C |
| Cooling Time | 55 minutes from 1210 to 300°C, 55 minutes from 300 to 100°C |
| Typical Time to Stability | 15 minutes |
| Well and Insert | |
| Immersion Depth | 5.43" (138 mm) with a Reference style insert, 4.57" (116 mm) with a Short style |
| Insert Outside Diameter | 0.98" (24.8 mm) |
| Insert Supplied | None; the well ships without an insert |
| Process Calibrator | |
| Reference Probe Input | External standard thermocouple, Type S or R |
| Thermocouple Channels | 4, patented TC terminals |
| Thermocouple Accuracy, Type K | ±0.182°C at 100°C, ±0.266°C at 300°C (channels 1 to 4) |
| Thermocouple Range | -75 to 75 mV on channels 1 to 4, -18 to 18 mV on the reference channel |
| Thermocouple Voltage Accuracy | 0.02% of reading + 8 µV on channels 1 to 4, 0.01% of reading + 2 µV on the reference channel |
| Internal Cold Junction Accuracy | ±0.35°C on channels 1 to 4, ±0.25°C on the reference channel |
| Current Range | -30 to 30 mA |
| Current Accuracy | ±0.02% of reading + 2 µA |
| Voltage Ranges | -12 to 12 V and -30 to 30 V |
| Voltage Accuracy | ±0.02% of reading + 2 mV |
| Switch Test | Mechanical or electrical on channels 1 and 2 |
| Loop Power Output | 24 V ±10%, 60 mA maximum |
| HART Communication | Read, configure and calibrate HART devices |
| Documentation | Up to 1000 tasks storing 10 results each, with as-found and as-left data |
| General | |
| Display | 6.5" (165 mm) color touch screen |
| Communication | USB-A, USB-B, RJ45, Wi-Fi, Bluetooth |
| Dimensions | 13.6 x 6.7 x 13.0" (345 x 170 x 330 mm) |
| Weight | 23.4 lb (10.6 kg) |
| Power Requirements | 90 to 254 V AC, 45 to 65 Hz, 580 W |
| Environmental Conditions | 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m |
| Storage Conditions | -20 to 60°C |
| Mechanical Testing | Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm) |
| Temperature Performance | |
| Temperature Range at 23°C | 100 to 1210°C |
| Display Accuracy | ±1.0°C at 100°C, ±1.0°C at 300°C, ±1.0°C at 600°C, ±1.2°C at 900°C, ±1.5°C at 1210°C |
| Stability | ±0.1°C |
| Axial Uniformity at 60 mm (2.4") | ±0.4°C at 100°C, ±0.8°C at 300°C, ±1.0°C at 600°C, ±1.0°C at 900°C, ±1.0°C at 1210°C |
| Radial Uniformity | ±0.2°C at 100°C, ±0.3°C at 300°C, ±0.4°C at 600°C, ±0.6°C at 900°C, ±0.8°C at 1210°C |
| Loading Effect | ±0.5°C |
| Resolution | 0.01°C |
| Temperature Units | °C, °F and K |
| Heating Time | 50 minutes from 23 to 1210°C |
| Cooling Time | 55 minutes from 1210 to 300°C, 55 minutes from 300 to 100°C |
| Typical Time to Stability | 15 minutes |
| Well and Insert | |
| Immersion Depth | 5.43" (138 mm) with a Reference style insert, 4.57" (116 mm) with a Short style |
| Insert Outside Diameter | 0.98" (24.8 mm) |
| Insert Supplied | None; the well ships without an insert |
| Process Calibrator | |
| Reference Probe Input | External standard thermocouple, Type S or R |
| Thermocouple Channels | 4, patented TC terminals |
| Thermocouple Accuracy, Type K | ±0.182°C at 100°C, ±0.266°C at 300°C (channels 1 to 4) |
| Thermocouple Range | -75 to 75 mV on channels 1 to 4, -18 to 18 mV on the reference channel |
| Thermocouple Voltage Accuracy | 0.02% of reading + 8 µV on channels 1 to 4, 0.01% of reading + 2 µV on the reference channel |
| Internal Cold Junction Accuracy | ±0.35°C on channels 1 to 4, ±0.25°C on the reference channel |
| Current Range | -30 to 30 mA |
| Current Accuracy | ±0.02% of reading + 2 µA |
| Voltage Ranges | -12 to 12 V and -30 to 30 V |
| Voltage Accuracy | ±0.02% of reading + 2 mV |
| Switch Test | Mechanical or electrical on channels 1 and 2 |
| Loop Power Output | 24 V ±10%, 60 mA maximum |
| HART Communication | Read, configure and calibrate HART devices |
| Documentation | Up to 1000 tasks storing 10 results each, with as-found and as-left data |
| General | |
| Display | 6.5" (165 mm) color touch screen |
| Communication | USB-A, USB-B, RJ45, Wi-Fi, Bluetooth |
| Dimensions | 13.6 x 6.7 x 13.0" (345 x 170 x 330 mm) |
| Weight | 23.4 lb (10.6 kg) |
| Power Requirements | 90 to 254 V AC, 45 to 65 Hz, 580 W |
| Environmental Conditions | 8 to 38°C for guaranteed accuracy, 0 to 50°C operating, 0% to 90% RH non-condensing, to 3000 m |
| Storage Conditions | -20 to 60°C |
| Mechanical Testing | Vibration 2 g (10 to 500 Hz) for 30 minutes on 2 sides; impact 4 g three times; drop test 19.6" (500 mm) |