The Ground Resistance Tester Model 6471 is a portable, versatile instrument for measuring ground resistance, bond/connection resistance, and soil resistivity plus clamp-on testing. It features auto-ranging, a large LCD for clear readings, and is CAT IV rated to 50 V with over-voltage protection. Housed in a durable, dust and water-sealed case, it operates on rechargeable NiMH batteries and includes an external charger. Ideal for maintenance crews, it meets IEC standards for shock, vibration, and drop tests, and its adjustable test frequency ensures accurate results even under challenging conditions.
The Ground Resistance Tester Model 6471 is a portable, versatile instrument for measuring ground resistance, bond/connection resistance, and soil resistivity plus clamp-on testing. It features auto-ranging, a large LCD for clear readings, and is CAT IV rated to 50 V with over-voltage protection. Housed in a durable, dust and water-sealed case, it operates on rechargeable NiMH batteries and includes an external charger. Ideal for maintenance crews, it meets IEC standards for shock, vibration, and drop tests, and its adjustable test frequency ensures accurate results even under challenging conditions.
Portable measurement instrument designed to measure ground resistance with 2 clamps (no auxiliary rods), bond/connection resistance (2-pole and 4-pole Kelvin sensing), ground resistance (3-pole or 4-pole), ground coupling resistance, and selective ground resistance, soil resistivity (Wenner or Schlumberger method). In addition, this ground resistance tester measures from 0.01 to 99.99 kΩ and is auto-ranging, automatically seeking out the optimum measurement range, test frequency and test current.
Features
Applications
2 Clamp Measurement | |
Range | 0.10 to 500 Ω |
Resolution | 0.01 to 1 Ω |
Measurement Frequency | Auto: 1611 Hz Manual: 128-1367-1611-1758 Hz |
3-Point Measurement | |
Range (Auto-Ranging) | 0.09 Ω to 99.9 kΩ |
Resolution | 0.01 to 100 Ω |
Test Voltage | Nominal 16 or 32 V RMS user selectable |
Resistance Measurement Frequency | 41 to 513 Hz automatic or user selectable |
Test Current | Up to 250 mA |
Accuracy | ±2% of reading + 1 ct at 128 Hz |
Soil Resistivity 4-Point Measurement | |
Test Method | Wenner or Schlumberger selectable with automatic calculation in Ω-meters, Ω-cm or Ω-feet |
Range (Auto-Ranging) | 0.01 to 99.99 kΩ (maximum 999 kΩm) |
Resolution | 0.001 to 10Ω |
Test Voltage | 16 or 32 V user selectable |
Frequency | From 41 to 128 Hz selectable |
External Voltage Measurement | |
Range (Auto-Ranging) | 0.1 to 65.0 V AC/DC - DC to 440 Hz |
Accuracy | ±2% of reading + 1 cts |
Resistance Measurement (Bond Testing) | |
Measurement Type | 2-pole (with lead resistance compensation) or 4-pole (Kelvin sensing) user selectable |
Range (Auto-Ranging) | 2-pole 0.12 to 99.9 kΩ 4-pole 0.02 to 99.99 kΩ |
Accuracy | ±2% of reading + 2 cts |
Test | Voltage: 16 V DC (+, - or auto polarity) Current: Up to 250 mA maximum |
Data Storage | |
Memory Capacity | 512 test results |
Communication | Optically isolated USB |
Power Source | 9.6 V rechargeable battery pack |
Recharging Source | 110/220, 50/60 Hz external charger with 18 V DC, 1.9 A output or 12 V vehicle power |
Click on a category to view a selection of compatible accessories with the AEMC 6471 Digital Ground Resistance Tester with DataView Software, 0.01 to 99.99 kΩ, 240 V AC, 3 and 4 point.
2 Clamp Measurement | |
Range | 0.10 to 500 Ω |
Resolution | 0.01 to 1 Ω |
Measurement Frequency | Auto: 1611 Hz Manual: 128-1367-1611-1758 Hz |
3-Point Measurement | |
Range (Auto-Ranging) | 0.09 Ω to 99.9 kΩ |
Resolution | 0.01 to 100 Ω |
Test Voltage | Nominal 16 or 32 V RMS user selectable |
Resistance Measurement Frequency | 41 to 513 Hz automatic or user selectable |
Test Current | Up to 250 mA |
Accuracy | ±2% of reading + 1 ct at 128 Hz |
Soil Resistivity 4-Point Measurement | |
Test Method | Wenner or Schlumberger selectable with automatic calculation in Ω-meters, Ω-cm or Ω-feet |
Range (Auto-Ranging) | 0.01 to 99.99 kΩ (maximum 999 kΩm) |
Resolution | 0.001 to 10Ω |
Test Voltage | 16 or 32 V user selectable |
Frequency | From 41 to 128 Hz selectable |
External Voltage Measurement | |
Range (Auto-Ranging) | 0.1 to 65.0 V AC/DC - DC to 440 Hz |
Accuracy | ±2% of reading + 1 cts |
Resistance Measurement (Bond Testing) | |
Measurement Type | 2-pole (with lead resistance compensation) or 4-pole (Kelvin sensing) user selectable |
Range (Auto-Ranging) | 2-pole 0.12 to 99.9 kΩ 4-pole 0.02 to 99.99 kΩ |
Accuracy | ±2% of reading + 2 cts |
Test | Voltage: 16 V DC (+, - or auto polarity) Current: Up to 250 mA maximum |
Data Storage | |
Memory Capacity | 512 test results |
Communication | Optically isolated USB |
Power Source | 9.6 V rechargeable battery pack |
Recharging Source | 110/220, 50/60 Hz external charger with 18 V DC, 1.9 A output or 12 V vehicle power |
Click on a category to view a selection of compatible accessories with the AEMC 6471 Digital Ground Resistance Tester with DataView Software, 0.01 to 99.99 kΩ, 240 V AC, 3 and 4 point.