Compact and shock-resistant, this three-phase power quality analyzer measures, diagnoses, and performs power quality work on one-, two-, or three-phase networks while prioritizing safety. Moreover, this analyzer has five voltage and four current inputs, can store, capture, and record data, and includes four AmpFlex® sensors.
Compact and shock-resistant, this three-phase power quality analyzer measures, diagnoses, and performs power quality work on one-, two-, or three-phase networks while prioritizing safety. Moreover, this analyzer has five voltage and four current inputs, can store, capture, and record data, and includes four AmpFlex® sensors.
The PowerPad® III Model 8436 is a three-phase power quality analyzer that is easy-to-use, compact and shock resistant. It enables technicians and engineers to measure and carry out diagnostics and power quality work on one-, two- or three- phase networks. Five voltage and four current inputs are provided. It is IEC 61000-4-30 Class B and safety rated to 600V CAT IV. It is rated IP67 when used with the flexible sensor Ampflex® 196A.
This three-phase power quality analyzer can record 2 GB of trend data on a memory card. Additional internal memory is used to let you store alarms, transients, and snapshot data. The user can store up to 50 screen snapshots, up to 210 captured transients that contain four cycles for each active input, and >16,000 alarm events from up to 40 different parameters. Trend data can also be recorded for days, weeks, or even months. Inrush current can also be captured and stored.
Features
Applications
Sampling Frequency | 256 samples/cycle |
Data Storage | SD card for trend recording Additional separate 12.5 MB partitioned memory for snapshots, transient/inrush and alarms |
Voltage (TRMS) | Phase-to-Phase: 2000 V Phase-to-Neutral: 1000 V Voltage Ratio: up to 500 kV |
Current (TRMS) | MN Clamp: 0 to 6 A / 120 A or 0 to 240 A SR Clamp: 0 to 1200 A MR Clamp: 0 to 1000 Aac, 0 to 1400 Adc MiniFlex®: 10 to 3000 A AmpFlex®: 10 to 10 kA (1) SL261 Clamp: 50 mA to 100 Aac/dc J93: 50 to 3500 Aac/dc Current Ratio: 10 mA to 50 kA |
Frequency (Hz) | 40 to 69 Hz |
Other Measurements | kW, kvar, kVA, PF, DPF, kWh, kvarh, kVAh, K-Factor, Flicker |
Harmonics | 1st to 50th, Direction, Sequence |
Communication Port | Optically isolated USB |
Inputs | 4 Voltage / 4 Current |
Sample Rate | 256 per Cycle 12.8 kHz at 50 Hz 15.36 kHz at 60 Hz |
Vrms (AC + DC) | Range: 1000 V P to N 2000 V P to P Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±0.5% reading + 200 mV |
Vpk | Range: 1414 V Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±3% reading + 2 V |
Vrms Half Cycle | Range: 1000 V P to N 2000 V P to P Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±0.8% reading + 1 V |
Amps (AC + DC) | Range: SR193 and MR193 Measurement range: 1 to 1000 A Resolution: 0.1 A Accuracy: ±0.5% reading + 200 mA Range: MN193 5 A Measurement range: 5 mA to 5 A Resolution: 1 mA Accuracy: ±0.5% reading + 2 mA Range: MN193 100 A Measurement range: 100 mA to 100 A Resolution: 10 mA Accuracy: ±0.5% reading + 20 mA |
AmpFlex and MiniFlex | Range: 100 A Measurement range: 100 mA to 100 A Resolution: 10 mA Accuracy: ±0.5% reading + 30 mA Range: 6500 A Measurement range: 10 to 6500 A Resolution: 0.1 A and 1 A Accuracy: ±0.5% reading + 3 A Range: 10 kA Measurement range: 10 A to 10 kA Resolution: 1 A Accuracy: ±0.5% reading + 3 A |
Apk | Range: SR193 and MR193 Measurement range: 1 to 1414 A Resolution: 0.1 A Accuracy: ±1% reading + 2 A Range: MN193 5 A Measurement range: 5 mA to 7.017 A Resolution: 1 mA Accuracy: ±1% reading + 20 mA Range: MN193 100 A Measurement range: 100 mA to 141.4 A Resolution: 10 mA Accuracy: ±1% reading + 200 mA |
Apk AmpFlex and MiniFlex | Range: 100 A Measurement range: 100 mA to 100 A Resolution: 0.1 A Accuracy: ±3% reading + 600mA Range: 6500 A Measurement range: 10 to 6500 A Resolution: 0.1 A and 1 A Accuracy: ±3% reading + 5 A Range: 10 kA Measurement range: 10 A to 10 kA Resolution: 1 A Accuracy: ±3% reading + 100 A |
A Half Cycle | Range: SR193 and MR193 Measurement range: 1 to 1200 A Resolution: 0.1 A Accuracy: ±1% reading + 10 A Range: MN193 5 A Measurement range: 5 mA to 6 A Resolution: 1 mA Accuracy: ±1% reading + 1mA Range: MN193 100 A Measurement range: 100 mA to 120 A Resolution: 10 mA Accuracy: ±1% reading + 100 mA |
Frequency | Range: 40 to 70 Hz Resolution: 0.01 Hz Accuracy (typical): ±0.01 Hz |
Power | Watts (VA, var) P-Q-S Probes: AmpFlex, MiniFlex Range: 10 mW to 10 MW 10 mW to 10 MW Resolution: 4 digits minimum Accuracy (typical): ±1% reading ±1.5% reading |
Power Factor (Cos Φ/DPF) | Range: -1 to 1 Resolution: 0.001 Accuracy (typical): ±1° for Φ, +5 cts for cos Φ |
Energy | kWh (kVAh, kvarh) P-Q-S Range: 1 mWh to 9,999,999 MWh (MVAh, Mvarh) Accuracy (typical): ±1% reading |
Harmonics | Range: DC, 1 to 50 |
Volts and Amp % | Range: f Measurement range: 0.0 to 1500% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts Range: r Measurement range: 0.0 to 100% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts Range: Absolute V Measurement range: 0 to 1000 V Resolution: 0.1 V Accuracy: ±2.5% reading + 1 V Range: Absolute A Measurement range: 0 to 1000 A Resolution: 0.1 A Accuracy: ±2% reading + 1 A Range: THD Measurement range: 0 to 999.9% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts |
Phase Angle | Range: -179° to 180° Resolution: 1° Accuracy (typical): ±1.5° + 1° × (n/12.5) |
Additional Features | Also display Energy loss, Flicker, Plt (2H), Pst (10min), Unbalance V% and A% |
Display | 1/4 VGA (320 x 240) color LCD display with adjustable brightness and contrast |
Power Source | 9.6 V NiMH rechargeable battery pack (included) 110 V to 1000 V DC to 400 Hz Battery life: ≥8 hours with display on; ≤35 hours with display off (record mode) |
Safety Rating | EN 61010, 600 V CAT IV(2), 1000 V CAT III, Pollution Degree 2 |
Dimensions | 10.6 x 9.8 x 7.1" (270 x 250 x 180 mm) |
Weight | 8.2 lbs (3.7 kg) with batteries |
Click on a category to view a selection of compatible accessories with the AEMC 8436 PowerPad® Three-Phase Power Quality Analyzer with AmpFlex sensors, 2000 V, 10 kA.
Sampling Frequency | 256 samples/cycle |
Data Storage | SD card for trend recording Additional separate 12.5 MB partitioned memory for snapshots, transient/inrush and alarms |
Voltage (TRMS) | Phase-to-Phase: 2000 V Phase-to-Neutral: 1000 V Voltage Ratio: up to 500 kV |
Current (TRMS) | MN Clamp: 0 to 6 A / 120 A or 0 to 240 A SR Clamp: 0 to 1200 A MR Clamp: 0 to 1000 Aac, 0 to 1400 Adc MiniFlex®: 10 to 3000 A AmpFlex®: 10 to 10 kA (1) SL261 Clamp: 50 mA to 100 Aac/dc J93: 50 to 3500 Aac/dc Current Ratio: 10 mA to 50 kA |
Frequency (Hz) | 40 to 69 Hz |
Other Measurements | kW, kvar, kVA, PF, DPF, kWh, kvarh, kVAh, K-Factor, Flicker |
Harmonics | 1st to 50th, Direction, Sequence |
Communication Port | Optically isolated USB |
Inputs | 4 Voltage / 4 Current |
Sample Rate | 256 per Cycle 12.8 kHz at 50 Hz 15.36 kHz at 60 Hz |
Vrms (AC + DC) | Range: 1000 V P to N 2000 V P to P Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±0.5% reading + 200 mV |
Vpk | Range: 1414 V Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±3% reading + 2 V |
Vrms Half Cycle | Range: 1000 V P to N 2000 V P to P Measurement range: 2 to 1000 V Resolution: 0.1 V Accuracy (typical): ±0.8% reading + 1 V |
Amps (AC + DC) | Range: SR193 and MR193 Measurement range: 1 to 1000 A Resolution: 0.1 A Accuracy: ±0.5% reading + 200 mA Range: MN193 5 A Measurement range: 5 mA to 5 A Resolution: 1 mA Accuracy: ±0.5% reading + 2 mA Range: MN193 100 A Measurement range: 100 mA to 100 A Resolution: 10 mA Accuracy: ±0.5% reading + 20 mA |
AmpFlex and MiniFlex | Range: 100 A Measurement range: 100 mA to 100 A Resolution: 10 mA Accuracy: ±0.5% reading + 30 mA Range: 6500 A Measurement range: 10 to 6500 A Resolution: 0.1 A and 1 A Accuracy: ±0.5% reading + 3 A Range: 10 kA Measurement range: 10 A to 10 kA Resolution: 1 A Accuracy: ±0.5% reading + 3 A |
Apk | Range: SR193 and MR193 Measurement range: 1 to 1414 A Resolution: 0.1 A Accuracy: ±1% reading + 2 A Range: MN193 5 A Measurement range: 5 mA to 7.017 A Resolution: 1 mA Accuracy: ±1% reading + 20 mA Range: MN193 100 A Measurement range: 100 mA to 141.4 A Resolution: 10 mA Accuracy: ±1% reading + 200 mA |
Apk AmpFlex and MiniFlex | Range: 100 A Measurement range: 100 mA to 100 A Resolution: 0.1 A Accuracy: ±3% reading + 600mA Range: 6500 A Measurement range: 10 to 6500 A Resolution: 0.1 A and 1 A Accuracy: ±3% reading + 5 A Range: 10 kA Measurement range: 10 A to 10 kA Resolution: 1 A Accuracy: ±3% reading + 100 A |
A Half Cycle | Range: SR193 and MR193 Measurement range: 1 to 1200 A Resolution: 0.1 A Accuracy: ±1% reading + 10 A Range: MN193 5 A Measurement range: 5 mA to 6 A Resolution: 1 mA Accuracy: ±1% reading + 1mA Range: MN193 100 A Measurement range: 100 mA to 120 A Resolution: 10 mA Accuracy: ±1% reading + 100 mA |
Frequency | Range: 40 to 70 Hz Resolution: 0.01 Hz Accuracy (typical): ±0.01 Hz |
Power | Watts (VA, var) P-Q-S Probes: AmpFlex, MiniFlex Range: 10 mW to 10 MW 10 mW to 10 MW Resolution: 4 digits minimum Accuracy (typical): ±1% reading ±1.5% reading |
Power Factor (Cos Φ/DPF) | Range: -1 to 1 Resolution: 0.001 Accuracy (typical): ±1° for Φ, +5 cts for cos Φ |
Energy | kWh (kVAh, kvarh) P-Q-S Range: 1 mWh to 9,999,999 MWh (MVAh, Mvarh) Accuracy (typical): ±1% reading |
Harmonics | Range: DC, 1 to 50 |
Volts and Amp % | Range: f Measurement range: 0.0 to 1500% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts Range: r Measurement range: 0.0 to 100% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts Range: Absolute V Measurement range: 0 to 1000 V Resolution: 0.1 V Accuracy: ±2.5% reading + 1 V Range: Absolute A Measurement range: 0 to 1000 A Resolution: 0.1 A Accuracy: ±2% reading + 1 A Range: THD Measurement range: 0 to 999.9% Resolution: 0.1% Accuracy: ±2.5% reading + 5cts |
Phase Angle | Range: -179° to 180° Resolution: 1° Accuracy (typical): ±1.5° + 1° × (n/12.5) |
Additional Features | Also display Energy loss, Flicker, Plt (2H), Pst (10min), Unbalance V% and A% |
Display | 1/4 VGA (320 x 240) color LCD display with adjustable brightness and contrast |
Power Source | 9.6 V NiMH rechargeable battery pack (included) 110 V to 1000 V DC to 400 Hz Battery life: ≥8 hours with display on; ≤35 hours with display off (record mode) |
Safety Rating | EN 61010, 600 V CAT IV(2), 1000 V CAT III, Pollution Degree 2 |
Dimensions | 10.6 x 9.8 x 7.1" (270 x 250 x 180 mm) |
Weight | 8.2 lbs (3.7 kg) with batteries |
Click on a category to view a selection of compatible accessories with the AEMC 8436 PowerPad® Three-Phase Power Quality Analyzer with AmpFlex sensors, 2000 V, 10 kA.