Provides the ability to display both voltage and current for each output. Provides a clean and stable output with <1mVrms of ripple.
Provides the ability to display both voltage and current for each output. Provides a clean and stable output with <1mVrms of ripple.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Power Supplies category for similar products.
Or let's do a search and help you find what you need:
The AX502 offers dual 30V outputs. It offers a unique master/slave tracking arrangement whereby the ratio between the master and slave can be setup on the fly as needed during the test. Adjusting the master voltage causes the slave to track. Adjusting the slave voltage causes the ratio from master to slave to change accordingly. It offers a Coarse and Fine voltage adjustment as well as a current limiting adjustment. It is built to provide many years of reliable, precise, easy-to-use operation and will be a welcome addition to any lab, test bench or production line.
Features
Applications
| Electrical | |
| Technology | Linear |
| Number of Outputs | 2 |
| Voltage | |
| Output 1 | 0 to 30V DC |
| Output 2 | 0 to 30V DC |
| Output 3 (No display) | N/A |
| Display Resolution | 100mV |
| Accuracy | ±0.5% Reading ±1ct |
| Ripple | ±1mVrms |
| Line Regulation | ±10% Line Voltage |
| Load Regulation | |
| 0 to 2.5A | ±0.02% Voltage Reading ±5mV |
| 0 to 5A | N/A |
| Current | |
| Output 1 | 0 to 2.5A |
| Output 2 | 0 to 2.5A |
| Output 3 (No display) | N/A |
| Resolution | 10mA |
| Basic Accuracy | ±0.5% Reading ±1ct |
| Limit Indicator | LED, Outputs 1 & 2 |
| Short-circuit Protection | Electronic current limitation with voltage shutdown |
| Overheating Protection | Thermal protection |
| Output Coupling | |
| Tracking | Output 1: Master Output 2: Slave Proportional Slave tracking 0 to 100% of Master |
| Series Mode | 0 to 60V DC / 0 to 2.5A |
| Parallel Mode | 0 to 30V DC / 0 to 5A |
| General | |
| Power Source | 115VAC ±10% |
| Display (LED) | Dual Display: VOLTAGE in Green, CURRENT in Red 0.56" (14.2mm) digit size |
| Operating Temperature Range | 50 to 104°F (10 to 40°C) |
| Operating Relative Humidity | <80% RH up to 104°F (40°C)</td> |
| Storage Temperature Range | -4 to 158°F (-20 to 70°C) |
| Dimensions | 10.63 x 8.86 x 4.73" (270 x 225 x 120mm) |
| Weight | 9.9 lbs (4.5kg) |
| Safety | |
| Rating | EN 61010-1, 100V Cat. I, CE Mark |
| Power Supply Inputs | Overvoltage Cat. 300V Cat. II |
| Electrical | |
| Technology | Linear |
| Number of Outputs | 2 |
| Voltage | |
| Output 1 | 0 to 30V DC |
| Output 2 | 0 to 30V DC |
| Output 3 (No display) | N/A |
| Display Resolution | 100mV |
| Accuracy | ±0.5% Reading ±1ct |
| Ripple | ±1mVrms |
| Line Regulation | ±10% Line Voltage |
| Load Regulation | |
| 0 to 2.5A | ±0.02% Voltage Reading ±5mV |
| 0 to 5A | N/A |
| Current | |
| Output 1 | 0 to 2.5A |
| Output 2 | 0 to 2.5A |
| Output 3 (No display) | N/A |
| Resolution | 10mA |
| Basic Accuracy | ±0.5% Reading ±1ct |
| Limit Indicator | LED, Outputs 1 & 2 |
| Short-circuit Protection | Electronic current limitation with voltage shutdown |
| Overheating Protection | Thermal protection |
| Output Coupling | |
| Tracking | Output 1: Master Output 2: Slave Proportional Slave tracking 0 to 100% of Master |
| Series Mode | 0 to 60V DC / 0 to 2.5A |
| Parallel Mode | 0 to 30V DC / 0 to 5A |
| General | |
| Power Source | 115VAC ±10% |
| Display (LED) | Dual Display: VOLTAGE in Green, CURRENT in Red 0.56" (14.2mm) digit size |
| Operating Temperature Range | 50 to 104°F (10 to 40°C) |
| Operating Relative Humidity | <80% RH up to 104°F (40°C)</td> |
| Storage Temperature Range | -4 to 158°F (-20 to 70°C) |
| Dimensions | 10.63 x 8.86 x 4.73" (270 x 225 x 120mm) |
| Weight | 9.9 lbs (4.5kg) |
| Safety | |
| Rating | EN 61010-1, 100V Cat. I, CE Mark |
| Power Supply Inputs | Overvoltage Cat. 300V Cat. II |