AEMC JM850A AC Current Probe, Jack, 1000A/2000A/3000A

Model: JM850A | Order No: 2110.87 | UPC: 685338090093

AEMC JM850A AC Current Probe, Jack, 1000A/2000A/3000A

Model: JM850A | Order No: 2110.87 | UPC: 685338090093

High performance AC Current Probe with excellent transformation and low phase shift. Features a nominal range of 1000A, 2000A, 3000A (continuous cycle for the full temperature range) and a transformation ratio of 1000:1, 2000:1, 3000:1.

High performance AC Current Probe with excellent transformation and low phase shift. Features a nominal range of 1000A, 2000A, 3000A (continuous cycle for the full temperature range) and a transformation ratio of 1000:1, 2000:1, 3000:1.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

AEMC JM810A AC Current Probe, Lead, 2000A AC-

AEMC JM810A AC Current Probe, Lead, 2000A AC

Model: JM810A | Order No: 2110.80

High performance AC Current Probe with excellent transformation and low phase shift. Features a nominal range of 1 to 2000A AC (continuous cycle for the full temperature range) and a Transformation ratio of 2000:2.


AEMC Instruments JM850A Offers

The high quality magnetic core and uniform windings provide for accurate measurements up to 1000A AC/2000A AC/3400A AC. The "squared" jaw permits multiple conductor or bus bar positioning. Provide excellent TRMS capabilities and reliable signal reproduction.

Features

  • Nominal range: 1000A, 2000A, 3000A (continuous cycle for the full temperature range)
  • Transformation ratio: 1000:1 2000:1, 3000:1
  • Output: 1mA/AC/AAC, 0.5mA/AC/A AC, 0.333mA/AC/A AC
  • Designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges

Applications

  • Electrical utility
  • HVAC/R
  • Industrial maintenance
  • Laboratory
  • Plant maintenance

AEMC Instruments JM850A Specifications

Nominal Range 1000A, 2000A, 3000A
Measurement Range 1 to 3400A
Transformation Ratio 1000:1, 2000:1, 3000:1
Output Signal 1mA AC/A AC (1A at 1000A)
0.5mA AC/A AC (1A at 2000A)
0.333mA AC/A AC (1A at 3000A)
Accuracy (1000A Range) 50A: 3% of Reading
200A: 1.5% of Reading
1000A: 1% of Reading
Phase Shift (1000A Range) 50A: 3°
200A: 1.5°
1000A: 1°
Accuracy (2000A Range) 100A: 1.5% of Reading
400A: 0.75% of Reading
2000A: 0.5% of Reading
Phase Shift (2000A Range) 100A: 1.5°
400A: 0.75°
2000A: 0.5°
Accuracy (3000A Range) 150A: 1.5% of Reading
600A: 0.75% of Reading
3000A: 0.5% of Reading
Phase Shift (2000A Range) 150A: 1.5°
600A: 0.75°
3000A: 0.5°
Overload 1400A for 10 min (1000A)
2400A for 10 min (2000A)
3400A for 10 min (3000A)
Frequency Range 30 to 1000Hz
Current derating above 1000Hz for continuous use
Load Impedance 2.5Ω (1000A)
5Ω (2000A
10Ω (3000A)
Working/Common Mode Voltage 600V AC
Output Termination Jack

What's included with the AEMC Instruments JM850A

  • AEMC JM850A AC Current Probe, Jack, 1000A/2000A/3000A

Ask a question about AEMC JM850A AC Current Probe, Jack, 1000A/2000A/3000A

Customer Reviews for the AEMC Instruments JM850A

AEMC Instruments JM850A Offers

The high quality magnetic core and uniform windings provide for accurate measurements up to 1000A AC/2000A AC/3400A AC. The "squared" jaw permits multiple conductor or bus bar positioning. Provide excellent TRMS capabilities and reliable signal reproduction.

Features

  • Nominal range: 1000A, 2000A, 3000A (continuous cycle for the full temperature range)
  • Transformation ratio: 1000:1 2000:1, 3000:1
  • Output: 1mA/AC/AAC, 0.5mA/AC/A AC, 0.333mA/AC/A AC
  • Designed for use on DMMs, power and harmonic meters, recorders or instruments with AC current ranges

Applications

  • Electrical utility
  • HVAC/R
  • Industrial maintenance
  • Laboratory
  • Plant maintenance

AEMC Instruments JM850A Specifications

Nominal Range 1000A, 2000A, 3000A
Measurement Range 1 to 3400A
Transformation Ratio 1000:1, 2000:1, 3000:1
Output Signal 1mA AC/A AC (1A at 1000A)
0.5mA AC/A AC (1A at 2000A)
0.333mA AC/A AC (1A at 3000A)
Accuracy (1000A Range) 50A: 3% of Reading
200A: 1.5% of Reading
1000A: 1% of Reading
Phase Shift (1000A Range) 50A: 3°
200A: 1.5°
1000A: 1°
Accuracy (2000A Range) 100A: 1.5% of Reading
400A: 0.75% of Reading
2000A: 0.5% of Reading
Phase Shift (2000A Range) 100A: 1.5°
400A: 0.75°
2000A: 0.5°
Accuracy (3000A Range) 150A: 1.5% of Reading
600A: 0.75% of Reading
3000A: 0.5% of Reading
Phase Shift (2000A Range) 150A: 1.5°
600A: 0.75°
3000A: 0.5°
Overload 1400A for 10 min (1000A)
2400A for 10 min (2000A)
3400A for 10 min (3000A)
Frequency Range 30 to 1000Hz
Current derating above 1000Hz for continuous use
Load Impedance 2.5Ω (1000A)
5Ω (2000A
10Ω (3000A)
Working/Common Mode Voltage 600V AC
Output Termination Jack

What's included with the AEMC Instruments JM850A

  • AEMC JM850A AC Current Probe, Jack, 1000A/2000A/3000A

Ask a question about AEMC JM850A AC Current Probe, Jack, 1000A/2000A/3000A

Customer Reviews for the AEMC Instruments JM850A

More AEMC Instruments Products