Altech 2DU6R D-Trip UL1077 Circuit Breaker, two-pole, 6.0 A

Model: 2DU6R

Altech 2DU6R D-Trip UL1077 Circuit Breaker, two-pole, 6.0 A

Model: 2DU6R

UL1077 recognized circuit breaker for supplementary protection has D-trip characteristics, magnetic trip-point, and relatively long thermal trip delay. In addition, this model is a two-pole 6 A with DIN rail-mounted miniature.

UL1077 recognized circuit breaker for supplementary protection has D-trip characteristics, magnetic trip-point, and relatively long thermal trip delay. In addition, this model is a two-pole 6 A with DIN rail-mounted miniature.

Sale Price $25.88 USD
Regular Price $34.97 USD
Availability 2 to 3 Weeks
Quantity

Altech 2DU6R Offers

Features

  • DIN rail mounted
  • Thermal magnetic
  • 10 kA short circuit withstand capacity
  • Positive trip indicator (Green-off/tripped, Red-on)

Applications

  • Control transformers
  • Power supplies
  • Reactive loads

Altech 2DU6R Specifications

Voltage Rating 480 Y /277 V AC
Short Circuit Withstand Rating (UL - Ratings) 0.5 to 6 A (RC): 10 kA with no back-up fuse
8 to 63 A (RC): 10 kA with UL-listed
Class J back-up fuse; 5 kA with no back-up fuse
Interrupting Capacity (IEC/EN60898/60947-2) 0.5 to 63 A (RC): 10 kA
Temperature Calibration: 86°F (30°C)
Operating: -13 to 140°F (-25 to 60°C)
Storage: -13 to 167°F (-25 to 75°C)
Terminal Size Acceptability and Torque 14-3 AWG: 17.5 lb-in (2.0 Nm)
18-16 AWG: 25 lb-in (2.8 Nm)
Terminal Protection Degree IP20 at front
Electrical Life 6,000 cycles on/off
Mechanical Life 10,000 cycles on/off
Wire Connection copper wire only 60/75°C
Vibration Resistance 3 g (18 to 50 Hz)
Mounting Orientation In any plane
Width 0.69" (17.5 mm) per pole
Click here for complete specifications on the Altech 2DU6R

What's included with the Altech 2DU6R

  • Altech 2DU6R D-Trip UL1077 Circuit Breaker, two-pole, 6.0 A

Ask a question about Altech 2DU6R D-Trip UL1077 Circuit Breaker, two-pole, 6.0 A

Customer Reviews for the Altech 2DU6R

Altech 2DU6R Offers

Features

  • DIN rail mounted
  • Thermal magnetic
  • 10 kA short circuit withstand capacity
  • Positive trip indicator (Green-off/tripped, Red-on)

Applications

  • Control transformers
  • Power supplies
  • Reactive loads

Altech 2DU6R Specifications

Voltage Rating 480 Y /277 V AC
Short Circuit Withstand Rating (UL - Ratings) 0.5 to 6 A (RC): 10 kA with no back-up fuse
8 to 63 A (RC): 10 kA with UL-listed
Class J back-up fuse; 5 kA with no back-up fuse
Interrupting Capacity (IEC/EN60898/60947-2) 0.5 to 63 A (RC): 10 kA
Temperature Calibration: 86°F (30°C)
Operating: -13 to 140°F (-25 to 60°C)
Storage: -13 to 167°F (-25 to 75°C)
Terminal Size Acceptability and Torque 14-3 AWG: 17.5 lb-in (2.0 Nm)
18-16 AWG: 25 lb-in (2.8 Nm)
Terminal Protection Degree IP20 at front
Electrical Life 6,000 cycles on/off
Mechanical Life 10,000 cycles on/off
Wire Connection copper wire only 60/75°C
Vibration Resistance 3 g (18 to 50 Hz)
Mounting Orientation In any plane
Width 0.69" (17.5 mm) per pole
Click here for complete specifications on the Altech 2DU6R