Ideal for non-contact voltage testing, this digital multimeter offers Voltect non-contact voltage technology along with a full complement of measurement functions. In addition, it features low battery indication, over-range indication, minimum/maximum, and data hold.
Ideal for non-contact voltage testing, this digital multimeter offers Voltect non-contact voltage technology along with a full complement of measurement functions. In addition, it features low battery indication, over-range indication, minimum/maximum, and data hold.
Manual ranging digital multimeter with non-contact voltage tester.
Features
Applications:
| DC Voltage Ranges | 200 mV, 2 V, 20 V, 200 V, 600 V |
| DC Voltage Accuracy | all Ranges: ± (1 % rdg + 1 dgt) |
| DC Voltage Resolution | 100 µV |
| DC Voltage Input Impedance | 10 MO |
| AC Voltage (45 Hz to 500 Hz) Ranges | 200 mV, 2 V, 20 V, 200 V, 600 V |
| AC Voltage (45 Hz to 500 Hz) Accuracy | all Ranges: ± (1.5 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) Resolution | 100 µV |
| AC Voltage (45 Hz to 500 Hz) Input Impedance | 10 MO |
| DC Current Ranges | 200 µA, 2 mA, 20 mA, 200 mA, 10 A |
| DC Current Accuracy | 200 µA to 200 mA Ranges: ± (1.5 % rdg + 1 dgt) |
| DC Current Accuracy | 10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current Resolution | 0.1 µA |
| DC Current voltage burden (max) | 200 µA range: 1 mV/µA |
| DC Current voltage burden (max) | 2 mA range: 100 mV/1mA |
| DC Current voltage burden (max) | 20 mA range: 13 mV/1 mA |
| DC Current voltage burden (max) | 200 mA range: 4.6 mV/1 mA |
| DC Current voltage burden (max) | 10A range: 40 mV/1 A |
| AC Current (45 Hz to 500 Hz) Ranges | 200 µA, 2 mA, 20 mA, 200 mA, 10 A |
| AC Current (45 Hz to 500 Hz) Accuracy | 200 µA to 200 mA Ranges: ± (2.0 % rdg + 4 dgts) |
| AC Current (45 Hz to 500 Hz) Accuracy | 10A Range: ± (2.5 % rdg + 4 dgts) |
| AC Current Resolution | 0.1 µA |
| AC Current voltage Burden | See DC Current |
| Non-contact voltage detector (NCV) AC Volts | 70 to 600 V ac |
| Non-contact voltage detector (NCV) | Red LED and Audible Indicator |
| DC Voltage Ranges | 200 mV, 2 V, 20 V, 200 V, 600 V |
| DC Voltage Accuracy | all Ranges: ± (1 % rdg + 1 dgt) |
| DC Voltage Resolution | 100 µV |
| DC Voltage Input Impedance | 10 MO |
| AC Voltage (45 Hz to 500 Hz) Ranges | 200 mV, 2 V, 20 V, 200 V, 600 V |
| AC Voltage (45 Hz to 500 Hz) Accuracy | all Ranges: ± (1.5 % rdg + 4 dgts) |
| AC Voltage (45 Hz to 500 Hz) Resolution | 100 µV |
| AC Voltage (45 Hz to 500 Hz) Input Impedance | 10 MO |
| DC Current Ranges | 200 µA, 2 mA, 20 mA, 200 mA, 10 A |
| DC Current Accuracy | 200 µA to 200 mA Ranges: ± (1.5 % rdg + 1 dgt) |
| DC Current Accuracy | 10 A range: ± (2.0 % rdg + 3 dgts) |
| DC Current Resolution | 0.1 µA |
| DC Current voltage burden (max) | 200 µA range: 1 mV/µA |
| DC Current voltage burden (max) | 2 mA range: 100 mV/1mA |
| DC Current voltage burden (max) | 20 mA range: 13 mV/1 mA |
| DC Current voltage burden (max) | 200 mA range: 4.6 mV/1 mA |
| DC Current voltage burden (max) | 10A range: 40 mV/1 A |
| AC Current (45 Hz to 500 Hz) Ranges | 200 µA, 2 mA, 20 mA, 200 mA, 10 A |
| AC Current (45 Hz to 500 Hz) Accuracy | 200 µA to 200 mA Ranges: ± (2.0 % rdg + 4 dgts) |
| AC Current (45 Hz to 500 Hz) Accuracy | 10A Range: ± (2.5 % rdg + 4 dgts) |
| AC Current Resolution | 0.1 µA |
| AC Current voltage Burden | See DC Current |
| Non-contact voltage detector (NCV) AC Volts | 70 to 600 V ac |
| Non-contact voltage detector (NCV) | Red LED and Audible Indicator |