Used to trace live, de-energized, or open (broken) wires behind walls that are up to 13 feet (4m) thick, safe to use in data centers.
Used to trace live, de-energized, or open (broken) wires behind walls that are up to 13 feet (4m) thick, safe to use in data centers.
Discontinued!
This product has been discontinued and is no longer available.
This is the direct replacement:
Features
General | |
Operating Temperature | 0 to 120°F (-18°C to 49°C) |
Storage Temperature | -40 to 150°F (-40° to 66°C) |
Case Material | ABS |
Case Size | 11" x 15.5" x 4" (39.4 x 27.9 x 10.2 cm) |
R2000 Receiver | |
Detectors | Electromagnetic coil pickup for short mode Electrostatic plate pickup for open mode |
Sensitivity Selection | x1, x10, x100 course gain adjustment; 0-10 fine adjustment |
Short Mode Performance | Over 20 feet in air under test conditions |
Open Mode Performance | Over 12 feet in air under test conditions |
60Hz Rejection | 120 db |
Power Source | 9V alkaline battery |
Display | 10 LED's with chroma filter lens |
S2600 Load Signal Generator | |
Operating Voltage | 9-600 volts AC or DC |
Operating Frequency | 32.768 KHz |
Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
Current Output | Low mode: 35 mA peak, 4mA average High mode: 70 mA peal, 6mA average |
Fuse | Fast acting 250mA @ 660V (6mm x 32mm)Cat. No. 660.25-6X32 |
T2200 Transmitter | |
Operating Frequency | 32.768 KHz |
Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
Fuse | Fast acting 2A @ 250V 3AG .25" x 1.25" Cat No. 2502-6x32 |
Battery | 9V alkaline - 24V jack will accept battery pack accessory (B2024 or B2025) |
Signal Output | 9V supply / 24V supply |
High Setting | 1A, 31V / 3A, 105V |
Medium Setting | 1.8A, 13V / 6A, 45V |
Low Setting | 3A, 6.5V / 10A, 22V |
A2201 Clamp-on Transmitter Accessory | |
Operating Frequency | 32.768 KHz as supplied by the T2200 |
Case Breakdown Voltage | 3000 V |
Maximum Wiresize | 2000 MCM or 2" dia. cable |
General | |
Operating Temperature | 0 to 120°F (-18°C to 49°C) |
Storage Temperature | -40 to 150°F (-40° to 66°C) |
Case Material | ABS |
Case Size | 11" x 15.5" x 4" (39.4 x 27.9 x 10.2 cm) |
R2000 Receiver | |
Detectors | Electromagnetic coil pickup for short mode Electrostatic plate pickup for open mode |
Sensitivity Selection | x1, x10, x100 course gain adjustment; 0-10 fine adjustment |
Short Mode Performance | Over 20 feet in air under test conditions |
Open Mode Performance | Over 12 feet in air under test conditions |
60Hz Rejection | 120 db |
Power Source | 9V alkaline battery |
Display | 10 LED's with chroma filter lens |
S2600 Load Signal Generator | |
Operating Voltage | 9-600 volts AC or DC |
Operating Frequency | 32.768 KHz |
Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
Current Output | Low mode: 35 mA peak, 4mA average High mode: 70 mA peal, 6mA average |
Fuse | Fast acting 250mA @ 660V (6mm x 32mm)Cat. No. 660.25-6X32 |
T2200 Transmitter | |
Operating Frequency | 32.768 KHz |
Duty Cycle | Transmits 2 pulses with a duration of 0.0625 every 0.5 seconds |
Fuse | Fast acting 2A @ 250V 3AG .25" x 1.25" Cat No. 2502-6x32 |
Battery | 9V alkaline - 24V jack will accept battery pack accessory (B2024 or B2025) |
Signal Output | 9V supply / 24V supply |
High Setting | 1A, 31V / 3A, 105V |
Medium Setting | 1.8A, 13V / 6A, 45V |
Low Setting | 3A, 6.5V / 10A, 22V |
A2201 Clamp-on Transmitter Accessory | |
Operating Frequency | 32.768 KHz as supplied by the T2200 |
Case Breakdown Voltage | 3000 V |
Maximum Wiresize | 2000 MCM or 2" dia. cable |