Featuring three power modes and two output frequencies, this transmitter incorporates the best technologies for optimal wire tracing and breaker identification on energized and de-energized circuits and automatically sets the signal based on detected voltage, delivering consistently accurate results.
Featuring three power modes and two output frequencies, this transmitter incorporates the best technologies for optimal wire tracing and breaker identification on energized and de-energized circuits and automatically sets the signal based on detected voltage, delivering consistently accurate results.
Discontinued!
This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:
Visit our Transmitters category for similar products.
Or let's do a search and help you find what you need:
Features
Applications
Current Output of Signal (Typical) | |
Energized Circuit | HI mode: 60 mA RMS LO mode: 30 mA RMS |
De-Energized Circuit | HI mode: 130 mA RMS LO mode: 40 mA RMS |
Signal Voltage Output (Nominal) | |
De-energized circuit | LOW: 29 V RMS, 120 Vp-p HIGH: 33V RMS, 140 Vp-p With CT-400: loop mode: 31 V RMS, 120 Vp-p |
General Specifications | |
Operating Temperature | -4 to 122°F (-20 to 50°C) |
Operating Humidity | -4 to <50°F (45%: -20 to <10°C) 50 to <86°F (95%: 10 to <30 °C) 86 to <104°F (75%: 30 to <40°C) 104to 122°F (45%: 40 to 50°C) |
Storage Temperature and Humidity | -4 to 158°F (-20 to 70°C), ≤ 95% RH |
Operating Altitude | 0 to 6561'(0 to 2000 m) |
Transient Protection | 8.00 kV (1.2/50μS surge) |
Drop Test | 3.28'(1 m) |
Fuse | 1.6 A, 700 V, fast-acting Ø 6 x 32 mm |
Response Time | Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec |
Voltage Warning Indicator | >30 V AC/DC |
Signal Indications | LEDs and audible beep |
Operating Frequency | Energized: 6.25 kHz De-Energized: 32.768 kHz |
Acoustic Indication | Audible beep |
Measurement Category | CAT IV 600 V |
Display Size | LED signals |
Booting Time | <2 seconds |
LED Indicator | Operating mode LEDs: red Battery status LEDs: green, yellow, red |
Pollution Degree | 2 |
IP Rating | IP 40 |
Power Supply | 8 x AA (alkaline or NiMH rechargeable) |
Power Consumption | Hi/Lo mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA |
Dimensions | x. 7.2 x 3.66 x 1.97'(183 x 93 x 50 mm) |
Weight | 1.25 lbs (0.57 kg) |
Current Output of Signal (Typical) | |
Energized Circuit | HI mode: 60 mA RMS LO mode: 30 mA RMS |
De-Energized Circuit | HI mode: 130 mA RMS LO mode: 40 mA RMS |
Signal Voltage Output (Nominal) | |
De-energized circuit | LOW: 29 V RMS, 120 Vp-p HIGH: 33V RMS, 140 Vp-p With CT-400: loop mode: 31 V RMS, 120 Vp-p |
General Specifications | |
Operating Temperature | -4 to 122°F (-20 to 50°C) |
Operating Humidity | -4 to <50°F (45%: -20 to <10°C) 50 to <86°F (95%: 10 to <30 °C) 86 to <104°F (75%: 30 to <40°C) 104to 122°F (45%: 40 to 50°C) |
Storage Temperature and Humidity | -4 to 158°F (-20 to 70°C), ≤ 95% RH |
Operating Altitude | 0 to 6561'(0 to 2000 m) |
Transient Protection | 8.00 kV (1.2/50μS surge) |
Drop Test | 3.28'(1 m) |
Fuse | 1.6 A, 700 V, fast-acting Ø 6 x 32 mm |
Response Time | Line voltage monitoring: 1 sec Battery voltage monitoring: 5 sec |
Voltage Warning Indicator | >30 V AC/DC |
Signal Indications | LEDs and audible beep |
Operating Frequency | Energized: 6.25 kHz De-Energized: 32.768 kHz |
Acoustic Indication | Audible beep |
Measurement Category | CAT IV 600 V |
Display Size | LED signals |
Booting Time | <2 seconds |
LED Indicator | Operating mode LEDs: red Battery status LEDs: green, yellow, red |
Pollution Degree | 2 |
IP Rating | IP 40 |
Power Supply | 8 x AA (alkaline or NiMH rechargeable) |
Power Consumption | Hi/Lo mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA |
Dimensions | x. 7.2 x 3.66 x 1.97'(183 x 93 x 50 mm) |
Weight | 1.25 lbs (0.57 kg) |