Amprobe CT-53 Flex Current Sensor, 3000A

Model: CT-53 | UPC: 095969808774

Amprobe CT-53 Flex Current Sensor, 3000A

Model: CT-53 | UPC: 095969808774

Flexible 3-Sensor Current Transducer with Selectable Input Range for use with the Amprobe DM-5 Power Quality Analyzer.

Flexible 3-Sensor Current Transducer with Selectable Input Range for use with the Amprobe DM-5 Power Quality Analyzer.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Sensors category for similar products.

Or let's do a search and help you find what you need:


Amprobe CT-53 Specifications

Current ranges 300A / 1000A / 3000A, AC rms
Output voltage 300 A range: 500 mVac / 300 Aac (1.67 mV / A)
1000A range: 500 mVac / 1000 Aac (0.5 mV / A)
3000A range: 500 mVac / 3000 Aac (0.167 mV / A)
Measuring range 300 A range: 30 A to 300 A (424 Apeak)
1000A range: 100A to 1000A (1414 Apeak)
3000A range: 300A to 3000A (4243 Apeak)
Accuracy (sine wave) ±1.0% (45 Hz to 65 Hz)
Working voltage 600 Vac rms
Max allowed input 3600 Aac continuous (45 Hz to 65 Hz)
Measurable conductor size Max. 150mm diameter
Output terminal Mini-DIN-6 connector
Output impedance 100 Ω or less
Current consumption
(at power supply 3 V)
15 mA (typical)
Operating temperature and humidity 32 to 122°F (0 to 50°C), ≤85 %RH (no condensation)
Guaranteed accuracy at 73°F ± 9°F (23°C ± 5°C), ≤85 %RH (no condensation)
Storage temperature and humidity -4 to 140°F (-20 to 60°C), ≤ 85 % RH (no condensation)
Operating altitude 0 to 2000m
Weight Approx. 950 g (2.1 lb)
Click here for complete specifications on the Amprobe CT-53

What's included with the Amprobe CT-53

  • Amprobe CT-53 Flex Current Sensor, 3000A

Ask a question about Amprobe CT-53 Flex Current Sensor, 3000A

Customer Reviews for the Amprobe CT-53

Amprobe CT-53 Specifications

Current ranges 300A / 1000A / 3000A, AC rms
Output voltage 300 A range: 500 mVac / 300 Aac (1.67 mV / A)
1000A range: 500 mVac / 1000 Aac (0.5 mV / A)
3000A range: 500 mVac / 3000 Aac (0.167 mV / A)
Measuring range 300 A range: 30 A to 300 A (424 Apeak)
1000A range: 100A to 1000A (1414 Apeak)
3000A range: 300A to 3000A (4243 Apeak)
Accuracy (sine wave) ±1.0% (45 Hz to 65 Hz)
Working voltage 600 Vac rms
Max allowed input 3600 Aac continuous (45 Hz to 65 Hz)
Measurable conductor size Max. 150mm diameter
Output terminal Mini-DIN-6 connector
Output impedance 100 Ω or less
Current consumption
(at power supply 3 V)
15 mA (typical)
Operating temperature and humidity 32 to 122°F (0 to 50°C), ≤85 %RH (no condensation)
Guaranteed accuracy at 73°F ± 9°F (23°C ± 5°C), ≤85 %RH (no condensation)
Storage temperature and humidity -4 to 140°F (-20 to 60°C), ≤ 85 % RH (no condensation)
Operating altitude 0 to 2000m
Weight Approx. 950 g (2.1 lb)