600A AC/DC True-RMS Clamp Multimeter. Offers a complete range of functions for electrical and industrial environments.
600A AC/DC True-RMS Clamp Multimeter. Offers a complete range of functions for electrical and industrial environments.
Features
Applications
AC voltage (True-rms) | Range: | 0 to 600.0 V |
Accuracy: | ±1.0% + 5LSD (50 to 60 Hz) | |
DC voltage | Range: | 0 to 600.0 V |
Accuracy: | ±1.0% + 5LSD | |
AC and DC Voltage | Range: | 0 to 600.0 V |
Accuracy: | ±1.2% + 7LSD (50 to 60 Hz) | |
AC current | Range: | 0 to 600.0 A |
Accuracy: | ±1.8% + 5LSD (50 to 60 Hz) ±2.0% + 5LSD (100 to 400 Hz) |
|
DC current | Range: | 0 to 600.0 A |
Accuracy: | ±2.0% + 5LSD (DC 50 to 100 Hz) | |
AC and DC Current | Range: | 0 to 600.0 A |
Accuracy: | ±2.2% + 7LSD (DC 50 to 100 Hz) ±2.7% + 7LSD (100 to 400 Hz) |
|
Precise low current AC | Range: | 0 to 60.00 A |
Accuracy: | ±1.5% + 5LSD (50 to 60 Hz) | |
Precise low current DC | Range: | 0 to 60.00 A |
Accuracy: | ±2.0% + 5LSD | |
Frequency | Range: | 5.00 to 999.9 Hz |
Accuracy: | ±1.0% + 5LSD (600 V range) | |
Resistance | Range: | 0.0 to 60.00 kΩ |
Accuracy: | ±1.0% + 5LSD | |
Capacitance | Range: | 0.0 to 2500 µF |
Accuracy: | ±2.0% + 4LSD | |
Continuity beeper | On: | ≤ 10 Ω |
Off: | > 250 Ω | |
Non-contact voltage | 10 V to 1000 V AC (50 to 60 Hz) | |
Diode test | yes | |
Jaw opening | 1.37 in (35 mm) | |
Saftey rating | CAT III 600 V |
AC voltage (True-rms) | Range: | 0 to 600.0 V |
Accuracy: | ±1.0% + 5LSD (50 to 60 Hz) | |
DC voltage | Range: | 0 to 600.0 V |
Accuracy: | ±1.0% + 5LSD | |
AC and DC Voltage | Range: | 0 to 600.0 V |
Accuracy: | ±1.2% + 7LSD (50 to 60 Hz) | |
AC current | Range: | 0 to 600.0 A |
Accuracy: | ±1.8% + 5LSD (50 to 60 Hz) ±2.0% + 5LSD (100 to 400 Hz) |
|
DC current | Range: | 0 to 600.0 A |
Accuracy: | ±2.0% + 5LSD (DC 50 to 100 Hz) | |
AC and DC Current | Range: | 0 to 600.0 A |
Accuracy: | ±2.2% + 7LSD (DC 50 to 100 Hz) ±2.7% + 7LSD (100 to 400 Hz) |
|
Precise low current AC | Range: | 0 to 60.00 A |
Accuracy: | ±1.5% + 5LSD (50 to 60 Hz) | |
Precise low current DC | Range: | 0 to 60.00 A |
Accuracy: | ±2.0% + 5LSD | |
Frequency | Range: | 5.00 to 999.9 Hz |
Accuracy: | ±1.0% + 5LSD (600 V range) | |
Resistance | Range: | 0.0 to 60.00 kΩ |
Accuracy: | ±1.0% + 5LSD | |
Capacitance | Range: | 0.0 to 2500 µF |
Accuracy: | ±2.0% + 4LSD | |
Continuity beeper | On: | ≤ 10 Ω |
Off: | > 250 Ω | |
Non-contact voltage | 10 V to 1000 V AC (50 to 60 Hz) | |
Diode test | yes | |
Jaw opening | 1.37 in (35 mm) | |
Saftey rating | CAT III 600 V |