Bacharach Fyrite INSIGHT Plus 0024-8516 with Reporting Kit and 2 Year O2 Sensor

Model: 0024-8516

Bacharach Fyrite INSIGHT Plus 0024-8516 with Reporting Kit and 2 Year O2 Sensor

Model: 0024-8516

Fast and accurate O2, CO (0-4,000 ppm), T-stack/air temperature and draft/pressure measurements. On-screen "hotspot finder" to detect the optimal measurement site.

Fast and accurate O2, CO (0-4,000 ppm), T-stack/air temperature and draft/pressure measurements. On-screen "hotspot finder" to detect the optimal measurement site.

Discontinued!

This product has been discontinued and is no longer available.
This is the direct replacement:

Bacharach 0024-8518 Fyrite Insight Plus Combustion Analyzer with reporting kit and 3 year 0<sub>2</sub> sensor-

Bacharach 0024-8518 Fyrite Insight Plus Combustion Analyzer with reporting kit and 3 year 02 sensor

Model: 0024-8518

The combustion analyzer is an all-in-one instrument that makes combustion tuning quick and easy with readings for 0⊂2, CO, CO⊂2, combustion efficiency, temperature, and draft. Additionally, it allows users to create custom reports with comments and send them through email.


Bacharach 0024-8516 Offers

Features

  • Five-in-one steady state combustion analyzer that is capable of measuring flue gas and room air CO, and can also function as a dual channel digital thermometer (up to 999°F) and a digital manometer (which measures draft, gas pressure, ESP, and up to ±40" w.c.)
  • On-screen "hotspot finder" to detect the optimal measurement site
  • Nine user-selectable fuels, plus 2 custom
  • B-Smart® technology enables in-field sensor replacement with pre-calibrated CO sensors, avoiding costly downtime and inconvenience
  • Manual zero/auto-zero (CO) feature
  • High CO shut-off/protection feature
  • 2-year or 3-year O2 sensor warranty
  • As easy as 1-2-3: Select fuel type, select appliance type and then start analysis
  • Exclusive Tune-Rite™ On-Demand HVAC/R Assistant: At the touch of a button, the software monitors the combustion analysis process in real-time to deliver the most accurate analysis every time; make instant troubleshooting suggestions; and provide guidance based on live data plus typical characteristics of the combustion appliance
  • Combustion analysis should be performed only after combustion para-meters indicate that the appliance has reached "steady-state" operating conditions. Steady-state can be gauged by three things: the change in temperature of combustion products in the vent system; the change in the percentage of oxygen in the flue gas mix, which assists in determining if there is excess air or excess fuel in the combustion process; the change in carbon monoxide (CO) over time - CO levels will spike during the initial fire which is normal, but they should normalize to a lower output as steady-state is reached
  • Tune-Rite™ software eliminates the guesswork commonly involved in determining steady-state by showing you a live graphical representation of all combustion parameters as they settle into a steady-state condition
  • Measured values of oxygen, stack temperature and carbon monoxide are compared to typical values for the equipment under optimum conditions
  • Programmed into the Tune-Rite™ software typical ranges for oxygen, stack temperature and carbon monoxide based on the fuel and equipment type which vary depending on the heating equipment and fuel type
  • Typical ranges can be seen in an easy-to-read bar graph format, along with the current values. Green, red and yellow indicators show whether the readings are in range (green), out of range (red), or unstable (yellow)
  • TuneRite™ software recommends possible causes for out-of-range measurements - and it will display a prioritized list of most likely potential issues to investigate
  • Using your saved "As Found" and "As Left" readings, Tune-Rite™ generates a comprehensive leave-behind service report showing the homeowner what was inspected, adjusted or repaired
  • Print stored data (100 records) and data download via USB with Fyrite® User Software

Bacharach 0024-8516 Specifications

Measured Ranges
Combustion Air Temperature -4 to 600°F (-20 to 316°C)
Flue Gas Temperature -4 to 1202°F (-20 to 650°C)
Oxygen (O2) 0.0 to 20.9%
Carbon Monoxide (CO2) 0 to 4,000 ppm
Draft/Differential Pressure: -40 to +40 INWC (100 mBar)
Calculated Ranges
Combustion Efficiency 0.1 to 100%
Carbon Dioxide (CO2) 0.1 to a fuel dependent max.value in percent
Carbon Monoxide (air free) 0 to 9,999 ppm
Excess Air 0 to 250%
General Specifications
User-Selectable Fuels 6 pre-programmed: Natural Gas, Oil #2, Oil #6, Kerosene, B5, and propane/LPG
(10 fuels avail able with Seigert model)
Data Storage Up to 10 complete records, internal storage
Power Supply 4 AA alkaline batteries
Dimensions 8.0 x 3.6 x 2.3" (203 x 91 x 58mm)/16 oz (0.45kg)
Click here for complete specifications on the Bacharach 0024-8516

What's included with the Bacharach 0024-8516

  • Combustion Analyzer
  • Probe
  • Protective Rubber Boot
  • Spare Filters
  • IrDA Printer
  • USB Cable
  • Fyrite® User Software
  • 8 'AA' Alkaline Batteries
  • Hard Carrying Case
  • User Manual

Click on a category to view a selection of compatible accessories with the Bacharach Fyrite INSIGHT Plus 0024-8516 with Reporting Kit and 2 Year O2 Sensor.

Bacharach 0024-1591 Long-Life O2 Replacement Sensor for the Fyrite Insight Plus Series 0024-1591
Compatible with the Fyrite Insight Plus Combustion Gas Analyzer.




Bacharach 0024-1593 CO Sensor for the Fyrite Insight Plus Series, NOx filter 0024-1593
Compatible with the Fyrite Insight Plus Combustion Gas Analyzer.




Bacharach B-Smart CO Sensor for the Fyrite, Insight, and Plus Series, pre-calibrated 0024-1616
Compatible with the Fryite, Insight and Plus Residential Combustion Analyzers.




Bacharach 0024-1611 Universal AC Power Adapter 0024-1611
For use with the Bacharach Fyrite Insight Plus Combustion Gas Analyzer.




Bacharach 0024-8242 Differential Pressure & Temperature Kit 0024-8242
For use with Bacharach Fryite Insight and Insight Plus Combustion Analyzers.




Bacharach 0104-1797 Combustion Air Temperature Thermocouple, 10 ft 0104-1797
10ft Thermocouple Probe that can be used with all of Bacharach Combustion Analyzers.




Bacharach 0104-1798 Type-K Ambient Air Temperature Thermocouple, 1" 0104-1798
Measuring 1" (25.4 mm) in length, this Type-K ambient air thermocouple is for use with combustion analyzers.




Bacharach 0024-1400 IrDA Printer 0024-1400
For use with Bacharach Combustion Analyzers and includes disposable batteries.




Bacharach 0007-1644 Replacement Filters for Water Trap, Pack of 3 07-1644
For use with Bacharach Residential Combustion Analyzers.




Ask a question about Bacharach Fyrite INSIGHT Plus 0024-8516 with Reporting Kit and 2 Year O2 Sensor

Customer Reviews for the Bacharach 0024-8516

Bacharach 0024-8516 Offers

Features

  • Five-in-one steady state combustion analyzer that is capable of measuring flue gas and room air CO, and can also function as a dual channel digital thermometer (up to 999°F) and a digital manometer (which measures draft, gas pressure, ESP, and up to ±40" w.c.)
  • On-screen "hotspot finder" to detect the optimal measurement site
  • Nine user-selectable fuels, plus 2 custom
  • B-Smart® technology enables in-field sensor replacement with pre-calibrated CO sensors, avoiding costly downtime and inconvenience
  • Manual zero/auto-zero (CO) feature
  • High CO shut-off/protection feature
  • 2-year or 3-year O2 sensor warranty
  • As easy as 1-2-3: Select fuel type, select appliance type and then start analysis
  • Exclusive Tune-Rite™ On-Demand HVAC/R Assistant: At the touch of a button, the software monitors the combustion analysis process in real-time to deliver the most accurate analysis every time; make instant troubleshooting suggestions; and provide guidance based on live data plus typical characteristics of the combustion appliance
  • Combustion analysis should be performed only after combustion para-meters indicate that the appliance has reached "steady-state" operating conditions. Steady-state can be gauged by three things: the change in temperature of combustion products in the vent system; the change in the percentage of oxygen in the flue gas mix, which assists in determining if there is excess air or excess fuel in the combustion process; the change in carbon monoxide (CO) over time - CO levels will spike during the initial fire which is normal, but they should normalize to a lower output as steady-state is reached
  • Tune-Rite™ software eliminates the guesswork commonly involved in determining steady-state by showing you a live graphical representation of all combustion parameters as they settle into a steady-state condition
  • Measured values of oxygen, stack temperature and carbon monoxide are compared to typical values for the equipment under optimum conditions
  • Programmed into the Tune-Rite™ software typical ranges for oxygen, stack temperature and carbon monoxide based on the fuel and equipment type which vary depending on the heating equipment and fuel type
  • Typical ranges can be seen in an easy-to-read bar graph format, along with the current values. Green, red and yellow indicators show whether the readings are in range (green), out of range (red), or unstable (yellow)
  • TuneRite™ software recommends possible causes for out-of-range measurements - and it will display a prioritized list of most likely potential issues to investigate
  • Using your saved "As Found" and "As Left" readings, Tune-Rite™ generates a comprehensive leave-behind service report showing the homeowner what was inspected, adjusted or repaired
  • Print stored data (100 records) and data download via USB with Fyrite® User Software

Bacharach 0024-8516 Specifications

Measured Ranges
Combustion Air Temperature -4 to 600°F (-20 to 316°C)
Flue Gas Temperature -4 to 1202°F (-20 to 650°C)
Oxygen (O2) 0.0 to 20.9%
Carbon Monoxide (CO2) 0 to 4,000 ppm
Draft/Differential Pressure: -40 to +40 INWC (100 mBar)
Calculated Ranges
Combustion Efficiency 0.1 to 100%
Carbon Dioxide (CO2) 0.1 to a fuel dependent max.value in percent
Carbon Monoxide (air free) 0 to 9,999 ppm
Excess Air 0 to 250%
General Specifications
User-Selectable Fuels 6 pre-programmed: Natural Gas, Oil #2, Oil #6, Kerosene, B5, and propane/LPG
(10 fuels avail able with Seigert model)
Data Storage Up to 10 complete records, internal storage
Power Supply 4 AA alkaline batteries
Dimensions 8.0 x 3.6 x 2.3" (203 x 91 x 58mm)/16 oz (0.45kg)
Click here for complete specifications on the Bacharach 0024-8516

What's included with the Bacharach 0024-8516

  • Combustion Analyzer
  • Probe
  • Protective Rubber Boot
  • Spare Filters
  • IrDA Printer
  • USB Cable
  • Fyrite® User Software
  • 8 'AA' Alkaline Batteries
  • Hard Carrying Case
  • User Manual

Click on a category to view a selection of compatible accessories with the Bacharach Fyrite INSIGHT Plus 0024-8516 with Reporting Kit and 2 Year O2 Sensor.

Bacharach 0024-1591 Long-Life O2 Replacement Sensor for the Fyrite Insight Plus Series 0024-1591
Compatible with the Fyrite Insight Plus Combustion Gas Analyzer.




Bacharach 0024-1593 CO Sensor for the Fyrite Insight Plus Series, NOx filter 0024-1593
Compatible with the Fyrite Insight Plus Combustion Gas Analyzer.




Bacharach B-Smart CO Sensor for the Fyrite, Insight, and Plus Series, pre-calibrated 0024-1616
Compatible with the Fryite, Insight and Plus Residential Combustion Analyzers.




Bacharach 0024-1611 Universal AC Power Adapter 0024-1611
For use with the Bacharach Fyrite Insight Plus Combustion Gas Analyzer.




Bacharach 0024-8242 Differential Pressure & Temperature Kit 0024-8242
For use with Bacharach Fryite Insight and Insight Plus Combustion Analyzers.




Bacharach 0104-1797 Combustion Air Temperature Thermocouple, 10 ft 0104-1797
10ft Thermocouple Probe that can be used with all of Bacharach Combustion Analyzers.




Bacharach 0104-1798 Type-K Ambient Air Temperature Thermocouple, 1" 0104-1798
Measuring 1" (25.4 mm) in length, this Type-K ambient air thermocouple is for use with combustion analyzers.




Bacharach 0024-1400 IrDA Printer 0024-1400
For use with Bacharach Combustion Analyzers and includes disposable batteries.




Bacharach 0007-1644 Replacement Filters for Water Trap, Pack of 3 07-1644
For use with Bacharach Residential Combustion Analyzers.




Ask a question about Bacharach Fyrite INSIGHT Plus 0024-8516 with Reporting Kit and 2 Year O2 Sensor

Customer Reviews for the Bacharach 0024-8516

More Bacharach Products