Compatible with the CFC and HCFC Refrigerant Leak Detectors, this gas leak analyzer can detect over 40 refrigerant gases and uses patented Advanced Leak Quantification (ALQ™) technology to quickly detect and quantify leaks.
Compatible with the CFC and HCFC Refrigerant Leak Detectors, this gas leak analyzer can detect over 40 refrigerant gases and uses patented Advanced Leak Quantification (ALQ™) technology to quickly detect and quantify leaks.
Many probe options, ranging from basic all the way to a "smart" probe that mirrors the instrument's user interface. Probes are available in 6 and 12 ft. lengths, enabling it to be customized to specific applications and user requirements.
Features
Applications
Gases Measured | Standard model: all CFC, HFC and HCFC refrigerants Including but not limited to: R-11, R-12, R-21, R-22, R-23, R-32, R-113, R-114, R-123, R-124, R-125, R-134a, R-227, R-236fa, R-401A, R-402A, R-402B, R-404A, R-407A, R-407C, R-408A, R-409A, R-410A, R-422A, R-422D, R-424A, R-426A, R-427A, R-438A, R-500, R-502, R-503, R-507, R-508B, HFP, H-1211, HFO-1234yf, H-1301, H-2402, N-1230, FA-188 and FC-72 |
Measurement Range | 0.03 to 3.49 oz/yr (1 to 99 g/yr) |
Sensitivity | 0.03 oz/yr (1 g/yr) |
Response Time | < 1 second (typical, dependent on probe length) |
Leak Indicators | Visual (instrument display and smart probe, if equipped) and Audible (via internal speaker or headphones) |
Power | 100 to 240 VAC, 50/60 Hz |
Size | Unit: 15.5 x 10.8 x 4.0" (39.4 x 27.3 x 10.2 cm) Probe: 6 ft |
Weight | 18.0 lbs (8.2 kg) |
Operating Conditions | 32 to 122°F (0 to 50°C), 5 to 90% RH (Non-Condensing), 1 ATM |
Warm-Up Time | 1 minute |
Approvals | CE mark; UL/CSA/IEC/EN 61010-1 |
Warranty | 2 Years |
Gases Measured | Standard model: all CFC, HFC and HCFC refrigerants Including but not limited to: R-11, R-12, R-21, R-22, R-23, R-32, R-113, R-114, R-123, R-124, R-125, R-134a, R-227, R-236fa, R-401A, R-402A, R-402B, R-404A, R-407A, R-407C, R-408A, R-409A, R-410A, R-422A, R-422D, R-424A, R-426A, R-427A, R-438A, R-500, R-502, R-503, R-507, R-508B, HFP, H-1211, HFO-1234yf, H-1301, H-2402, N-1230, FA-188 and FC-72 |
Measurement Range | 0.03 to 3.49 oz/yr (1 to 99 g/yr) |
Sensitivity | 0.03 oz/yr (1 g/yr) |
Response Time | < 1 second (typical, dependent on probe length) |
Leak Indicators | Visual (instrument display and smart probe, if equipped) and Audible (via internal speaker or headphones) |
Power | 100 to 240 VAC, 50/60 Hz |
Size | Unit: 15.5 x 10.8 x 4.0" (39.4 x 27.3 x 10.2 cm) Probe: 6 ft |
Weight | 18.0 lbs (8.2 kg) |
Operating Conditions | 32 to 122°F (0 to 50°C), 5 to 90% RH (Non-Condensing), 1 ATM |
Warm-Up Time | 1 minute |
Approvals | CE mark; UL/CSA/IEC/EN 61010-1 |
Warranty | 2 Years |