Bacharach 7-08-1234-33-0 Refrigerant Analyzer Legend

Model: 7-08-1234-33-0

Bacharach 7-08-1234-33-0 Refrigerant Analyzer Legend

Model: 7-08-1234-33-0

This portable refrigerant analyzer is designed to assess the purity of refrigerant storage cylinders or directly in vehicle air conditioning systems. Furthermore, it measures R-1234yf, R-134a, and R-12 refrigerants while detecting the presence of harmful refrigerants or air.

This portable refrigerant analyzer is designed to assess the purity of refrigerant storage cylinders or directly in vehicle air conditioning systems. Furthermore, it measures R-1234yf, R-134a, and R-12 refrigerants while detecting the presence of harmful refrigerants or air.

Sale Price $4247.10 USD
Regular Price $4719.00 USD
Availability 2 to 3 Weeks
Quantity

Bacharach 7-08-1234-33-0 Offers

With the introduction of the new HFO-1234yf refrigerant to the automobile market, vehicle manufacturers worldwide have developed new standards for vehicle A/C service. These standards require that the refrigerant purity be verified prior to the recovery of the refrigerant from a system. The acceptable refrigerant purity as defined by the SAE is a refrigerant mixture that contains 98. 0% or greater of R-1234yf or R-134a by weight. The Neutronics gas refrigerant identifier will meet the service needs of HFO-1234yf equipped vehicles.

The Neutronic automotive analyzer is certified to the SAE J2912 standard and connects directly to SAE J2843 and J3030 AC Service machines that have an external analyzer USB port. The Neutronics Legend refrigerant identifier control panel serves as the user interface. The control panel features three soft buttons, a full-color graphic LCD, and an alarm to alert of an instrument fault condition or contaminated refrigerant presence. The sample gas is admitted into the instrument through the sample hose and presented to the sensing device. After analysis, the refrigerant analyzer provides the user with a digital display of refrigerant purity and color cues. The refrigerant analyzer only considers the weights of the refrigerant and contaminates in the total mixture. Air is measured and displayed separately. Other contents such as refrigerant oil and dye are not considered contaminants.

Understanding Test Results: A green background will be displayed if the refrigerant sample is 98% pure or greater. In this case, the refrigerant is deemed suitable for standard recovery and reuse. A yellow background will be displayed if the refrigerant sample is between 95% - 98% pure. In this case, the refrigerant is not suitable for standard recovery and should not be reused. A red screen is displayed when the sampled refrigerant is less than 95% pure, presents hydrocarbons, or has large contamination. Caution should be taken when handling this vehicle or cylinder. It is important to note air is measured independently of the refrigerant. This means you could have a percentage of AIR present in a sample or refrigerant that totals or equals 100% refrigerant.

Features

  • Quickly and accurately determines refrigerant purity
  • Displays percentage purity of R-1234yf, R-134a, R-12, R-22 and Hydrocarbons
  • Displays % air in pure R-1234yf andamp; R-134a
  • Capable of testing R-12 with optional R-12 hose accessory
  • Improved oil resistance with the user replaceable oil restrictor
  • Store test data on external USB drive
  • Supports 10 languages for global operations
  • Quickly and accurately determines refrigerant purity
  • Advanced ergonomic design
  • Displays % purity for R-1234yf, R-134a, and R-12
  • Displays % for R-22, unknown refrigerant, and hydrocarbons
  • Displays air % independent of the refrigerant sampled
  • Capable of analyzing R-12 (1/4 flare coupler sold separately)
  • Multiple languages: English (default), German, Spanish, French, Italian, Portuguese, Chinese, Japanese, Korean, and Russian
  • Improved oil resistance with user replaceable hose assembly
  • Fender-compatible resting surface
  • Full color liquid crystal display (LCD) with on-screen instructions
  • Accelerated 70 second test time
  • Internal, rechargeable lithium-ion battery for cordless operation in any location
  • USB port for connection to the A/C service machine and remote software updates
  • All accessories stored in a hard-shell portable storage case

Applications

  • Automotive technicians, shop owners, refrigerant suppliers, A/C service equipment, and customer's vehicle to meet requirements for safe refrigerant practices.

Bacharach 7-08-1234-33-0 Specifications

Measuring Range 90 to 100% Pure Refrigerant for analyzed gases
Accuracy +/-2%
Resolution Exceeds the requirements of SAE J2912
User Interface Graphic Display, Soft Keys, Built in Printer
Display Size 5" (12.70 cm)
Power Supply Input: 90/264 V AC, 50/60 HZ Output: 12 V DC, 1.6 A
Digital Communications USB 2.0, Optional Bluetooth 2.0
Operating Voltage 12 V DC
Ambient Temperature 50 to 120°F (10 to 49°C)
Humidity 0 to 95% RH non-condensing
Pressure Adequate 30 to 500 psig (2 to 34 Bar)
Altitude 0 to 8000' (2,440 m)
Dimensions 10.5 x 6 x 3" (26.67 x 15.24 x 7.62 cm)
Product Weight 3.5 lbs (1.6 kg)
Approvals CE, UL, SAE J2912
Warranty 1 Year
Sample Type Vapor
Refrigerant % Displayed R-1234yf, R-134a, R-12, R-22, Hydrocarbons (HC), Unknown, Air
Refrigerants Measured R-1234yf, R-134a, R-12
Contaminants Measured R-22, Hydrocarbons, Unknown
Communication Protocols USB 2.0, Bluetooth 2.0
Languages ENG, FRE, GER, ITA, POR, SPA, CHI, JAP, KOR, RUS
Test Time 90 seconds

What's included with the Bacharach 7-08-1234-33-0

  • Refrigerant Analyzer Legend 7-08-1234-33-0
  • Couplers for both R-134a and R-1234yf
  • 2 x R-1234yf sample hoses
  • 2 x R-134a sample hoses
  • Sample hose extensions
  • AC power supply
  • Tank adapters for both R-134a and R-1234yf
  • Internal Rechargeable Battery
  • Internal Air Sensor And All Required Plumbing
  • Rugged, Portable, Storage Case
  • One-year Warranty

Ask a question about Bacharach 7-08-1234-33-0 Refrigerant Analyzer Legend

Customer Reviews for the Bacharach 7-08-1234-33-0

Bacharach 7-08-1234-33-0 Offers

With the introduction of the new HFO-1234yf refrigerant to the automobile market, vehicle manufacturers worldwide have developed new standards for vehicle A/C service. These standards require that the refrigerant purity be verified prior to the recovery of the refrigerant from a system. The acceptable refrigerant purity as defined by the SAE is a refrigerant mixture that contains 98. 0% or greater of R-1234yf or R-134a by weight. The Neutronics gas refrigerant identifier will meet the service needs of HFO-1234yf equipped vehicles.

The Neutronic automotive analyzer is certified to the SAE J2912 standard and connects directly to SAE J2843 and J3030 AC Service machines that have an external analyzer USB port. The Neutronics Legend refrigerant identifier control panel serves as the user interface. The control panel features three soft buttons, a full-color graphic LCD, and an alarm to alert of an instrument fault condition or contaminated refrigerant presence. The sample gas is admitted into the instrument through the sample hose and presented to the sensing device. After analysis, the refrigerant analyzer provides the user with a digital display of refrigerant purity and color cues. The refrigerant analyzer only considers the weights of the refrigerant and contaminates in the total mixture. Air is measured and displayed separately. Other contents such as refrigerant oil and dye are not considered contaminants.

Understanding Test Results: A green background will be displayed if the refrigerant sample is 98% pure or greater. In this case, the refrigerant is deemed suitable for standard recovery and reuse. A yellow background will be displayed if the refrigerant sample is between 95% - 98% pure. In this case, the refrigerant is not suitable for standard recovery and should not be reused. A red screen is displayed when the sampled refrigerant is less than 95% pure, presents hydrocarbons, or has large contamination. Caution should be taken when handling this vehicle or cylinder. It is important to note air is measured independently of the refrigerant. This means you could have a percentage of AIR present in a sample or refrigerant that totals or equals 100% refrigerant.

Features

  • Quickly and accurately determines refrigerant purity
  • Displays percentage purity of R-1234yf, R-134a, R-12, R-22 and Hydrocarbons
  • Displays % air in pure R-1234yf andamp; R-134a
  • Capable of testing R-12 with optional R-12 hose accessory
  • Improved oil resistance with the user replaceable oil restrictor
  • Store test data on external USB drive
  • Supports 10 languages for global operations
  • Quickly and accurately determines refrigerant purity
  • Advanced ergonomic design
  • Displays % purity for R-1234yf, R-134a, and R-12
  • Displays % for R-22, unknown refrigerant, and hydrocarbons
  • Displays air % independent of the refrigerant sampled
  • Capable of analyzing R-12 (1/4 flare coupler sold separately)
  • Multiple languages: English (default), German, Spanish, French, Italian, Portuguese, Chinese, Japanese, Korean, and Russian
  • Improved oil resistance with user replaceable hose assembly
  • Fender-compatible resting surface
  • Full color liquid crystal display (LCD) with on-screen instructions
  • Accelerated 70 second test time
  • Internal, rechargeable lithium-ion battery for cordless operation in any location
  • USB port for connection to the A/C service machine and remote software updates
  • All accessories stored in a hard-shell portable storage case

Applications

  • Automotive technicians, shop owners, refrigerant suppliers, A/C service equipment, and customer's vehicle to meet requirements for safe refrigerant practices.

Bacharach 7-08-1234-33-0 Specifications

Measuring Range 90 to 100% Pure Refrigerant for analyzed gases
Accuracy +/-2%
Resolution Exceeds the requirements of SAE J2912
User Interface Graphic Display, Soft Keys, Built in Printer
Display Size 5" (12.70 cm)
Power Supply Input: 90/264 V AC, 50/60 HZ Output: 12 V DC, 1.6 A
Digital Communications USB 2.0, Optional Bluetooth 2.0
Operating Voltage 12 V DC
Ambient Temperature 50 to 120°F (10 to 49°C)
Humidity 0 to 95% RH non-condensing
Pressure Adequate 30 to 500 psig (2 to 34 Bar)
Altitude 0 to 8000' (2,440 m)
Dimensions 10.5 x 6 x 3" (26.67 x 15.24 x 7.62 cm)
Product Weight 3.5 lbs (1.6 kg)
Approvals CE, UL, SAE J2912
Warranty 1 Year
Sample Type Vapor
Refrigerant % Displayed R-1234yf, R-134a, R-12, R-22, Hydrocarbons (HC), Unknown, Air
Refrigerants Measured R-1234yf, R-134a, R-12
Contaminants Measured R-22, Hydrocarbons, Unknown
Communication Protocols USB 2.0, Bluetooth 2.0
Languages ENG, FRE, GER, ITA, POR, SPA, CHI, JAP, KOR, RUS
Test Time 90 seconds

What's included with the Bacharach 7-08-1234-33-0

  • Refrigerant Analyzer Legend 7-08-1234-33-0
  • Couplers for both R-134a and R-1234yf
  • 2 x R-1234yf sample hoses
  • 2 x R-134a sample hoses
  • Sample hose extensions
  • AC power supply
  • Tank adapters for both R-134a and R-1234yf
  • Internal Rechargeable Battery
  • Internal Air Sensor And All Required Plumbing
  • Rugged, Portable, Storage Case
  • One-year Warranty

Ask a question about Bacharach 7-08-1234-33-0 Refrigerant Analyzer Legend

Customer Reviews for the Bacharach 7-08-1234-33-0

More Bacharach Products