TX4000 TDR Cable Fault Locator is designed for identifying and locating faults on all metallic cables with two or more insulated conductors. This cable fault locator TDR is a hand-held Time Domain Reflectometer with 11 range scales up to 4000m (4km).
TX4000 TDR Cable Fault Locator is designed for identifying and locating faults on all metallic cables with two or more insulated conductors. This cable fault locator TDR is a hand-held Time Domain Reflectometer with 11 range scales up to 4000m (4km).
Features
Ranges | Meters 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km feet 23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 13120 |
Range Selection | Manual range control |
Accuracy | 1% of selected range |
Resolution | Approx 1% of range |
Sensitivity | Min 3 pixel return at 4km on 0,6mm , PE , TP |
Velocity Factor | Adjustable from 1% to 99% |
Output Pulse | 5 volts peak to peak. Into open circuit |
Output Impedance | Selectable 25, 50, 75 and 100 ohms |
Output Pulse Width | 3 ns to 3 ms, Automatic with range |
Scan Rate | 2 scans / second or scan held (not on 3km/6km range) |
Tone Generator | 810 to 1100Hz |
Battery Life | 60 hours continuous scanning |
Power Supply | 6 volts 4 x 1.5 AA Alkaline cells |
Power Down | Selectable 1, 2, 3, 5 minutes or disabled |
Back Lit Display | 128 x 64 pixel |
Voltage Detection | 250 volts AC |
Operating Temp | -10 to 50°C |
Storage Temp | -20 to 70°C |
Safety | IEC 61010-1, EN 60950, EMC BS/EN 61326-1, IP54 |
Dimensions | 165 x 90 x 37mm (6.5 x 3.5 x 1.5 ins) |
Weight | 350 g (12 oz) |
Ranges | Meters 7, 15, 30, 60, 120, 250, 500, 1km, 2km, 3km, 4km feet 23, 49, 98, 197, 394, 820, 1640, 3280, 6560, 9850, 13120 |
Range Selection | Manual range control |
Accuracy | 1% of selected range |
Resolution | Approx 1% of range |
Sensitivity | Min 3 pixel return at 4km on 0,6mm , PE , TP |
Velocity Factor | Adjustable from 1% to 99% |
Output Pulse | 5 volts peak to peak. Into open circuit |
Output Impedance | Selectable 25, 50, 75 and 100 ohms |
Output Pulse Width | 3 ns to 3 ms, Automatic with range |
Scan Rate | 2 scans / second or scan held (not on 3km/6km range) |
Tone Generator | 810 to 1100Hz |
Battery Life | 60 hours continuous scanning |
Power Supply | 6 volts 4 x 1.5 AA Alkaline cells |
Power Down | Selectable 1, 2, 3, 5 minutes or disabled |
Back Lit Display | 128 x 64 pixel |
Voltage Detection | 250 volts AC |
Operating Temp | -10 to 50°C |
Storage Temp | -20 to 70°C |
Safety | IEC 61010-1, EN 60950, EMC BS/EN 61326-1, IP54 |
Dimensions | 165 x 90 x 37mm (6.5 x 3.5 x 1.5 ins) |
Weight | 350 g (12 oz) |