Built with a design using dust-penetrating technology, this scanner measures multiple points for unsurpassed bin volume accuracy. Additionally, when used in a multi-scanner system, it provides accurate readings of level and volume for stored materials based on two or more synchronized MVL units with extended temperature up to 365"F.
Built with a design using dust-penetrating technology, this scanner measures multiple points for unsurpassed bin volume accuracy. Additionally, when used in a multi-scanner system, it provides accurate readings of level and volume for stored materials based on two or more synchronized MVL units with extended temperature up to 365"F.
Features
Applications
Measuring Range | 200' (61 meters) |
Process Temperatures | -40 to 185°F (-40 to 85°C) Standard |
Process Pressure | -2.9 to 14.5 psi (-0.2 to 3 bar) |
Signal Output | 4-wire 4 to 20 mA / HART / RS-485 / Modbus |
Emitting Frequency | 3 to 10 KHz |
Supply Voltage | 20 to 32 VDC |
Power Consumption | Maximum 1.5 W @ 24 VDC |
Preferred Applications | Powders and solids |
Hazardous Locations | CFM Intrinsically Safe Class I, II, Division I, Groups C, D, E, F, G (US & Canada) |
Click on a category to view a selection of compatible accessories with the BinMaster 3DLS-MVL-HT Hight Temperature Multiple Scanner System, 365"F.
Measuring Range | 200' (61 meters) |
Process Temperatures | -40 to 185°F (-40 to 85°C) Standard |
Process Pressure | -2.9 to 14.5 psi (-0.2 to 3 bar) |
Signal Output | 4-wire 4 to 20 mA / HART / RS-485 / Modbus |
Emitting Frequency | 3 to 10 KHz |
Supply Voltage | 20 to 32 VDC |
Power Consumption | Maximum 1.5 W @ 24 VDC |
Preferred Applications | Powders and solids |
Hazardous Locations | CFM Intrinsically Safe Class I, II, Division I, Groups C, D, E, F, G (US & Canada) |
Click on a category to view a selection of compatible accessories with the BinMaster 3DLS-MVL-HT Hight Temperature Multiple Scanner System, 365"F.