Delivers up to 1440 W of clean power on a single output, this DC power supply has a compact and high-density 1U to meet the needs of both system integrators and benchtop users. In addition, it provides an output voltage/current of up to 100 V/14.4 A and features GPIB, LAN, USB, and RS485 interfaces.
Delivers up to 1440 W of clean power on a single output, this DC power supply has a compact and high-density 1U to meet the needs of both system integrators and benchtop users. In addition, it provides an output voltage/current of up to 100 V/14.4 A and features GPIB, LAN, USB, and RS485 interfaces.
Features
Master/slave operation
Up to four models with the same rating can be connected in parallel or series and operate in master/slave mode. The RS485 interface is used for communication between the master and slave(s). Once configured, the master will automatically search for and detect slave units, and display the voltage and current of the complete system.
Extensive device protection
To protect your DUT, this unit provides more safety features than any other system power supply in this category: overvoltage (OVP), overcurrent (OCP), overpower (OPP), and overtemperature (OTP) protection. When a fault occurs, the power supply will turn off the output, sound an alarm, and display an error message. Similarly, with constant voltage-to-constant current (CV-to-CC) or constant current-to-constant voltage (CC-to-CV) foldback protection mode activated, the supply will shut down if load changes force the supply to transition between the two operating modes. This power supply is also able to detect abnormally low AC input power and turn the output off when this condition occurs.
Current flow timer for breaker or fuse testing
It can be used to accurately measure the time for a fuse or circuit breaker to open. After the voltage and current levels are set, the On/Off button turns on the output and the time when the fuse/breaker opens is measured to the nearest 100 µs. The maximum counting period is one hour.
External analog programming interface
In addition to the front panel or remote interface control, voltage and current values can also be programmed with an analog control signal. This power supply can be externally controlled from zero to full scale by an analog voltage source (0 to 5 V/0 to 10 V selectable).
Test sequence execution in list mode
The list mode feature allows users to download a list of commands to the power supply's internal memory and execute them. Up to 10 sets of programs can be stored with a total of 150 steps allocated among the memory locations. The test sequence can be programmed remotely via the USB, GPIB, or LAN interfaces using SCPI commands or the included application software. Each step's voltage, current, and duration parameters can be set, with sequences configured for single or repeated execution.
Applications
Perfectly suited for ATE systems integration, product design and development, product QC and burn-in testing, and other applications requiring excellent regulation, high power, low noise, and a wide range of voltage and current ratings.
Output Ratings | Output voltage: 0 to 100 V Output current: 0 to 14.4 A |
Output Protection | OVP adjustment range: 5 to 105 V OVP accuracy: 500 mV |
Regulation | Line: Voltage: ≤10 mV Current: ≤4 mA Load: Voltage: ≤12 mV Current: ≤6 mA |
Ripple and Noise (20 Hz to 20 MHz) | Normal mode voltage (load ≥0.5% of maximum load): ≤8 mVrms/≤80 mVpp Normal current mode: ≤40 mA |
Programming Resolution | Programming and readback: 2.5 mV/1 mA |
Programming and Readback Accuracy ±(% Output + Offset) |
Voltage: 0.05% + 25 mV Current: 0.05% + 6 mA |
Average Command Response Time | ≤50 ms |
Power Factor Correction (PFC) | ≥0.99 (full load) |
Efficiency | ≥80% (full load) |
Remote Sense Compensation | 2 V |
Rise Time at Full/No Load | ≤30 ms |
Fall Time | Full load: ≤30 ms No load: ≤1000 ms |
Transient Response Time | ≤1 ms |
AC Line Rated Input Voltage/Hz | 100 to 240 V AC /47 to 63 Hz |
Tolerance/Variation in Voltage | -15 to 10% (10% power de-rating mode when voltage under 95 V AC) |
Maximum Rated Input Power | 1700 VA |
Temperature Ratings | Operating: 32 to 104°F (0 to 40°C) Storage: 14 to 158°F (-10 to 70°C) |
Interface | USB, RS485, analog interface, LAN, GPIB |
Electromagnetic Compatibility | EMC Directive 2004/108/EC, EN61326-1: 2006, CISPR11, Class B, EN 61000 3-2 : 2006, EN 61000-3-3: 1995 + A1: 2001 + A2: 2005, EN 61000-4-2/-3/-4/-5/-6/-11 |
Safety | EN61010-1:2001, EU Low Voltage Directive 2006/95/EC |
Dimensions | 16.5 x 1.72 x 17" (420 x 43.6 x 432 mm) |
Weight | 19.8 lbs (9 kg) |
Output Ratings | Output voltage: 0 to 100 V Output current: 0 to 14.4 A |
Output Protection | OVP adjustment range: 5 to 105 V OVP accuracy: 500 mV |
Regulation | Line: Voltage: ≤10 mV Current: ≤4 mA Load: Voltage: ≤12 mV Current: ≤6 mA |
Ripple and Noise (20 Hz to 20 MHz) | Normal mode voltage (load ≥0.5% of maximum load): ≤8 mVrms/≤80 mVpp Normal current mode: ≤40 mA |
Programming Resolution | Programming and readback: 2.5 mV/1 mA |
Programming and Readback Accuracy ±(% Output + Offset) |
Voltage: 0.05% + 25 mV Current: 0.05% + 6 mA |
Average Command Response Time | ≤50 ms |
Power Factor Correction (PFC) | ≥0.99 (full load) |
Efficiency | ≥80% (full load) |
Remote Sense Compensation | 2 V |
Rise Time at Full/No Load | ≤30 ms |
Fall Time | Full load: ≤30 ms No load: ≤1000 ms |
Transient Response Time | ≤1 ms |
AC Line Rated Input Voltage/Hz | 100 to 240 V AC /47 to 63 Hz |
Tolerance/Variation in Voltage | -15 to 10% (10% power de-rating mode when voltage under 95 V AC) |
Maximum Rated Input Power | 1700 VA |
Temperature Ratings | Operating: 32 to 104°F (0 to 40°C) Storage: 14 to 158°F (-10 to 70°C) |
Interface | USB, RS485, analog interface, LAN, GPIB |
Electromagnetic Compatibility | EMC Directive 2004/108/EC, EN61326-1: 2006, CISPR11, Class B, EN 61000 3-2 : 2006, EN 61000-3-3: 1995 + A1: 2001 + A2: 2005, EN 61000-4-2/-3/-4/-5/-6/-11 |
Safety | EN61010-1:2001, EU Low Voltage Directive 2006/95/EC |
Dimensions | 16.5 x 1.72 x 17" (420 x 43.6 x 432 mm) |
Weight | 19.8 lbs (9 kg) |