Blancett 1100 Turbine Flow Meter with 304 SS flange connections, 100 to 1200 gpm, 600# RF

Model: B111-140-FECAA

Blancett 1100 Turbine Flow Meter with 304 SS flange connections, 100 to 1200 gpm, 600# RF

Model: B111-140-FECAA

Ideal for liquid flow measurement on/off the oil field, this flow meter can withstand the demands of the most rigorous flow measurement applications. In addition, it offers accurate and repeatable flow measurements from 100 to 1200 gpm (3400 to 41,000 bpd) and has a maximum pressure of 1440 psi and 304 stainless steel flange connections.

Ideal for liquid flow measurement on/off the oil field, this flow meter can withstand the demands of the most rigorous flow measurement applications. In addition, it offers accurate and repeatable flow measurements from 100 to 1200 gpm (3400 to 41,000 bpd) and has a maximum pressure of 1440 psi and 304 stainless steel flange connections.

Regular Price $7422.00 USD
Availability 2 to 3 Weeks
Quantity

Blancett B111-140-FECAA Offers

Whether on or off the oil field, this turbine flow meter maintains measurement accuracy and mechanical integrity in the corrosive and abrasive fluids commonly found in water flood projects and many industrial applications.

Features

  • Offers accurate and repeatable flow measurement
  • Cost-effective solution for turbine flow meter applications
  • Simple installation: Built for simple installation and service, requiring a minimum of 10 diameters upstream and 5 diameters downstream straight pipe length
  • Flexible operation: Designed to operate in any orientation (horizontal to vertical) as long as the flow direction arrow is aligned with the actual line flow
  • Durable construction: Rugged 316 stainless steel housing and rotor support assemblies with CD4CU stainless steel rotor offers long service life in severe operating environments
  • NPT end connections
  • Can integrate electronically with a Blancett flow monitor (sold separately)
  • K-factor Scaler, or the F to I/F to V Intelligent Converter Field replaceable repair kits (sold separately) allow for turbine replacement without loss of accuracy

Installation

This turbine meter is simple to install and service. It operates in any orientation (horizontal to vertical) as long as the "flow direction" arrow is aligned in the same direction as the actual line flow. For optimum performance, the flow meter should be installed with a minimum of 10 diameters upstream straight pipe length and 5 diameters downstream straight pipe length.

Operating principle

Fluid entering the meter passes through the inlet flow straightener which reduces its turbulent flow pattern and improves the fluid's velocity profile. Fluid then passes through the turbine, causing it to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field at the base of the transducer, an AC voltage pulse is generated in the pickup coil. These pulses produce an output frequency proportional to the volumetric flow through the meter.

K-factor

The K-factor represents the number of output pulses transmitted per gallon of fluid passing through this turbine meter. Each turbine has a unique K-factor. However, turbine meters are not functionally consistent throughout the full flow range of the meter. There are several forms of friction inherent in this turbine meter that retards the rotational movement of the turbine rotor. These frictional forces include: magnetic drag, created by electromagnetic forces of pickup transducers; mechanical drag, due to bearing friction; and viscous drag, produced by flowing fluid. As flow increases, the frictional forces are minimized and the free-wheeling motion of the turbine rotor becomes more linear (proportional to flow). The K-factor becomes relatively constant and the linear throughout the balance of the linear flow range. This is approximately a 10:1 turndown ratio from the maximum flow rate down to the minimum flow rate.

Applications

  • Concrete production and consolidation
  • Utility water treatment and distribution
  • Oil and gas
  • Process and general industry
  • Refining, chemical, and petrochemical

Blancett B111-140-FECAA Specifications

Flow Ranges 100 to 1200 gpm (378.5 to 4542.5 lpm)
3400 to 41,000 bpd
545 to 6540 m3/d
Maximum Pressure 1440 psi
Approximate K-Factor Pulse/Gal 29
Flow Accuracy ±1% of reading
Repeatability ±0.1%
Turndown Ratio 10:1
Calibration Water (NIST traceable calibration)
Strainer Mesh 10
End Connections 600# RF
Operating Temperature -150 to 350°F (-101 to 177°C)
Materials Body: 316 stainless steel
Rotor: CD4MCU stainless steel
Rotor Shaft: Tungsten carbide
Rotor Support: 316 stainless steel
Flanges: 304 stainless steel
Certifications CSA Class I Div 1, Groups C and D
Class II Div 1, Groups E, F and G: intrinsically safe
CSA Class I Div 1, Groups C and D; complies with UL 1203 and CSA 22.2 No. 30
Magnetic Pickup Body thread: ⅝ to 18 UNF
Termination type: 2-pin MS
Mounthing thread electrical: MS3106-10SL-4S
Output: MAG (mV Freq)
Resistance: 1500 Ω ±10%
Gauss: ~1200
Temperature range: -150 to 330°F (-101 to 165°C)
Pinouts: A = Coil, B = Coil (no polarity)
Dimensions Meter: 4" (101.6 mm)
Bore size: 4" (101.6 mm)
End-to-end length: 12" (304.8 mm)
Click here for complete specifications on the Blancett B111-140-FECAA

What's included with the Blancett B111-140-FECAA

  • Turbine Flow Meter
  • NIST Traceable Calibration
  • One-Year Warranty

Ask a question about Blancett 1100 Turbine Flow Meter with 304 SS flange connections, 100 to 1200 gpm, 600# RF

Customer Reviews for the Blancett B111-140-FECAA

Blancett B111-140-FECAA Offers

Whether on or off the oil field, this turbine flow meter maintains measurement accuracy and mechanical integrity in the corrosive and abrasive fluids commonly found in water flood projects and many industrial applications.

Features

  • Offers accurate and repeatable flow measurement
  • Cost-effective solution for turbine flow meter applications
  • Simple installation: Built for simple installation and service, requiring a minimum of 10 diameters upstream and 5 diameters downstream straight pipe length
  • Flexible operation: Designed to operate in any orientation (horizontal to vertical) as long as the flow direction arrow is aligned with the actual line flow
  • Durable construction: Rugged 316 stainless steel housing and rotor support assemblies with CD4CU stainless steel rotor offers long service life in severe operating environments
  • NPT end connections
  • Can integrate electronically with a Blancett flow monitor (sold separately)
  • K-factor Scaler, or the F to I/F to V Intelligent Converter Field replaceable repair kits (sold separately) allow for turbine replacement without loss of accuracy

Installation

This turbine meter is simple to install and service. It operates in any orientation (horizontal to vertical) as long as the "flow direction" arrow is aligned in the same direction as the actual line flow. For optimum performance, the flow meter should be installed with a minimum of 10 diameters upstream straight pipe length and 5 diameters downstream straight pipe length.

Operating principle

Fluid entering the meter passes through the inlet flow straightener which reduces its turbulent flow pattern and improves the fluid's velocity profile. Fluid then passes through the turbine, causing it to rotate at a speed proportional to fluid velocity. As each turbine blade passes through the magnetic field at the base of the transducer, an AC voltage pulse is generated in the pickup coil. These pulses produce an output frequency proportional to the volumetric flow through the meter.

K-factor

The K-factor represents the number of output pulses transmitted per gallon of fluid passing through this turbine meter. Each turbine has a unique K-factor. However, turbine meters are not functionally consistent throughout the full flow range of the meter. There are several forms of friction inherent in this turbine meter that retards the rotational movement of the turbine rotor. These frictional forces include: magnetic drag, created by electromagnetic forces of pickup transducers; mechanical drag, due to bearing friction; and viscous drag, produced by flowing fluid. As flow increases, the frictional forces are minimized and the free-wheeling motion of the turbine rotor becomes more linear (proportional to flow). The K-factor becomes relatively constant and the linear throughout the balance of the linear flow range. This is approximately a 10:1 turndown ratio from the maximum flow rate down to the minimum flow rate.

Applications

  • Concrete production and consolidation
  • Utility water treatment and distribution
  • Oil and gas
  • Process and general industry
  • Refining, chemical, and petrochemical

Blancett B111-140-FECAA Specifications

Flow Ranges 100 to 1200 gpm (378.5 to 4542.5 lpm)
3400 to 41,000 bpd
545 to 6540 m3/d
Maximum Pressure 1440 psi
Approximate K-Factor Pulse/Gal 29
Flow Accuracy ±1% of reading
Repeatability ±0.1%
Turndown Ratio 10:1
Calibration Water (NIST traceable calibration)
Strainer Mesh 10
End Connections 600# RF
Operating Temperature -150 to 350°F (-101 to 177°C)
Materials Body: 316 stainless steel
Rotor: CD4MCU stainless steel
Rotor Shaft: Tungsten carbide
Rotor Support: 316 stainless steel
Flanges: 304 stainless steel
Certifications CSA Class I Div 1, Groups C and D
Class II Div 1, Groups E, F and G: intrinsically safe
CSA Class I Div 1, Groups C and D; complies with UL 1203 and CSA 22.2 No. 30
Magnetic Pickup Body thread: ⅝ to 18 UNF
Termination type: 2-pin MS
Mounthing thread electrical: MS3106-10SL-4S
Output: MAG (mV Freq)
Resistance: 1500 Ω ±10%
Gauss: ~1200
Temperature range: -150 to 330°F (-101 to 165°C)
Pinouts: A = Coil, B = Coil (no polarity)
Dimensions Meter: 4" (101.6 mm)
Bore size: 4" (101.6 mm)
End-to-end length: 12" (304.8 mm)
Click here for complete specifications on the Blancett B111-140-FECAA

What's included with the Blancett B111-140-FECAA

  • Turbine Flow Meter
  • NIST Traceable Calibration
  • One-Year Warranty