Designed for monitoring voltage, current, power, and energy on single- and three-phase circuits, this 12-channel power submeter is supplied as a board on a mounting plate with no local display. Additionally, it samples continuously at 7.2 kHz at Class 0.2 accuracy. It suits panel builds and OEM assemblies.
Designed for monitoring voltage, current, power, and energy on single- and three-phase circuits, this 12-channel power submeter is supplied as a board on a mounting plate with no local display. Additionally, it samples continuously at 7.2 kHz at Class 0.2 accuracy. It suits panel builds and OEM assemblies.
PowerScout™ FLEX 12 is DENT’s next-generation multi-circuit submeter engineered for faster setup, smarter commissioning, and clearer system insight. Replacing the PowerScout™ HD, FLEX simplifies installation, enhances configuration workflows, and delivers accurate, real-time data across a wide range of electrical environments. Whether deploying in the field or overseeing large-scale facilities, FLEX provides the flexibility, performance, and control today’s teams need.
Features
Applications
| Service Type | Single phase, split phase, three phase-four wire (WYE), three phase-three wire (delta) |
| Power | Supply: from L1 phase to L2 phase, 90-600 V AC RMS CAT III 50/60 Hz, 500 mA AC maximum |
| Voltage Channels | 90-346 V AC line-to-neutral, 600 V line-to-line, CAT III |
| Current Channels | 12 channels, 0.525 V AC maximum, 333.3 mV CTs, 0-4,000 amps depending on CT |
| Measurement | Type: true RMS using high-speed digital signal processing (DSP) with continuous sampling |
| Measurements | Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (delivered) kWh, export (received) kWh, net kWh, import (delivered) kVAh, export (received) kVAh, net kVAh, import (delivered) kVARh, export (received) kVARh, net kVARh, THD, theta, frequency; all parameters for each phase and virtual meter |
| Accuracy | 0.2% ANSI C12.1-2024 Class 0.2 |
| Resolution | Values in IEEE-754 single precision floating point format (32 bit) |
| Alarm Output | Under voltage (open collector - 30 V DC maximum) |
| Pulse Inputs | Four inputs, 3.3 V sourcing voltage (current limited) to customer dry contact pulse output; maximum pulse rate 10 Hz (50 ms minimum transition time) |
| Communications | Hardware: RS-485, Ethernet, and USB (for configuration only) |
| Wire Connections | 12-28 AWG 600 V AC; voltage connection must be #14 AWG or larger and 600 V AC rated |
| Mounting | Panel mount/enclosure |
| High Voltage Cover | IP30; supplied with PS12 enclosure models |
| Environment | Operating temperature: -4 to 140°F (-20 to 60°C) |
| Enclosure | ABS plastic, 94-V0 flammability rating; connections: 1" (2.54 cm) EMT conduit |
| Certifications | UL Recognized (E186827): conforms to UL Std 61010-1 3rd Edition, certified to CSA Std C22.2 No. 61010-1 3rd Edition |
| FLEXPoint Software | Operating system: Windows® 11, Windows® 10 |
| Dimensions | 7 x 10.4 x 3.1" (17.8 x 26.3 x 8 cm) |
| Service Type | Single phase, split phase, three phase-four wire (WYE), three phase-three wire (delta) |
| Power | Supply: from L1 phase to L2 phase, 90-600 V AC RMS CAT III 50/60 Hz, 500 mA AC maximum |
| Voltage Channels | 90-346 V AC line-to-neutral, 600 V line-to-line, CAT III |
| Current Channels | 12 channels, 0.525 V AC maximum, 333.3 mV CTs, 0-4,000 amps depending on CT |
| Measurement | Type: true RMS using high-speed digital signal processing (DSP) with continuous sampling |
| Measurements | Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (delivered) kWh, export (received) kWh, net kWh, import (delivered) kVAh, export (received) kVAh, net kVAh, import (delivered) kVARh, export (received) kVARh, net kVARh, THD, theta, frequency; all parameters for each phase and virtual meter |
| Accuracy | 0.2% ANSI C12.1-2024 Class 0.2 |
| Resolution | Values in IEEE-754 single precision floating point format (32 bit) |
| Alarm Output | Under voltage (open collector - 30 V DC maximum) |
| Pulse Inputs | Four inputs, 3.3 V sourcing voltage (current limited) to customer dry contact pulse output; maximum pulse rate 10 Hz (50 ms minimum transition time) |
| Communications | Hardware: RS-485, Ethernet, and USB (for configuration only) |
| Wire Connections | 12-28 AWG 600 V AC; voltage connection must be #14 AWG or larger and 600 V AC rated |
| Mounting | Panel mount/enclosure |
| High Voltage Cover | IP30; supplied with PS12 enclosure models |
| Environment | Operating temperature: -4 to 140°F (-20 to 60°C) |
| Enclosure | ABS plastic, 94-V0 flammability rating; connections: 1" (2.54 cm) EMT conduit |
| Certifications | UL Recognized (E186827): conforms to UL Std 61010-1 3rd Edition, certified to CSA Std C22.2 No. 61010-1 3rd Edition |
| FLEXPoint Software | Operating system: Windows® 11, Windows® 10 |
| Dimensions | 7 x 10.4 x 3.1" (17.8 x 26.3 x 8 cm) |