Ideal for superior energy measurements, this versatile multi-circuit power submeter features 48 channels for monitoring voltage, current, power, energy, and many other electrical parameters on any combination of single and three-phase systems. In addition, this revenue-grade submeter comes with an enclosure and a display.
Ideal for superior energy measurements, this versatile multi-circuit power submeter features 48 channels for monitoring voltage, current, power, energy, and many other electrical parameters on any combination of single and three-phase systems. In addition, this revenue-grade submeter comes with an enclosure and a display.
Features
Applications
| AC Protection | 0.5 A fuse 200 kA interrupt capacity |
| Accuracy | 0.2% ANSI C12.20-2010 Class 0.2 |
| Current Channels | 48 channels, 0.525 VAC maximum, 333 mV CTs, 0 to 4000+ A, depending on CT |
| Data Bits | 8 |
| Data Formats | Modbus, BACnet MS/TP, Modbus TCP or BACnet IP |
| Dimensions | 13.5 x 10 x 3" (34.3 x 25.4 x 7.6 cm) |
| Display | 4-line display, tri-color backlight (PhaseChek) |
| Hardware | RS-485, Ethernet, and USB (for ViewPoint HD use only) |
| Line Frequency | 50/60 Hz |
| Max Distance | 1200 meters with data range of 100 K bits per second or less |
| Maximum Current Input | 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs |
| Measurement Type | True RMS using high-speed digital signal processing (DSP) with continuous sampling |
| Measurements | Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (received) kWh, export (delivered) kWh, net kWh, import (received) kVAh, export (delivered) kVAh, net kVAh, import (received) kVARh, export (delivered) kVARh, net kVARh, THD, theta, frequency. All parameters for each phase and system total |
| Parameter Update Rate | 1 second |
| Parity | None, even, odd |
| Power | From L1 phase to L2 phase. 90 to 600 VAC RMS CAT III 50/60 Hz, 500 mA AC maximum |
| Power Out | Unregulated 12 VDC output, 200 mA, self-resetting fuse |
| Resolution | Values reported in IEEE-754 single precision floating point format (32 bit) |
| Service Type | Single phase, split phase, three phase-four wire (WYE), three phase-three wire (delta) |
| Stop Bit | 2, 1 |
| Supported BAUD Rates | 9600, 19200, 38400, 57600, 76800, 115200 |
| Supported Protocols | Modbus (using SunSpec IEEE-754 single precision floating point model), or BACnet |
| Voltage Channels | 80 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III |
| Waveform Sampling | 1.8 kHz |
| AC Protection | 0.5 A fuse 200 kA interrupt capacity |
| Accuracy | 0.2% ANSI C12.20-2010 Class 0.2 |
| Current Channels | 48 channels, 0.525 VAC maximum, 333 mV CTs, 0 to 4000+ A, depending on CT |
| Data Bits | 8 |
| Data Formats | Modbus, BACnet MS/TP, Modbus TCP or BACnet IP |
| Dimensions | 13.5 x 10 x 3" (34.3 x 25.4 x 7.6 cm) |
| Display | 4-line display, tri-color backlight (PhaseChek) |
| Hardware | RS-485, Ethernet, and USB (for ViewPoint HD use only) |
| Line Frequency | 50/60 Hz |
| Max Distance | 1200 meters with data range of 100 K bits per second or less |
| Maximum Current Input | 150% of current transducer rating (mV CTs) to maintain accuracy. Measure up to 4000 A with RōCoil CTs |
| Measurement Type | True RMS using high-speed digital signal processing (DSP) with continuous sampling |
| Measurements | Volts, amps, kW, kVAR, kVA, aPF, dPF, kW demand, kVA demand, import (received) kWh, export (delivered) kWh, net kWh, import (received) kVAh, export (delivered) kVAh, net kVAh, import (received) kVARh, export (delivered) kVARh, net kVARh, THD, theta, frequency. All parameters for each phase and system total |
| Parameter Update Rate | 1 second |
| Parity | None, even, odd |
| Power | From L1 phase to L2 phase. 90 to 600 VAC RMS CAT III 50/60 Hz, 500 mA AC maximum |
| Power Out | Unregulated 12 VDC output, 200 mA, self-resetting fuse |
| Resolution | Values reported in IEEE-754 single precision floating point format (32 bit) |
| Service Type | Single phase, split phase, three phase-four wire (WYE), three phase-three wire (delta) |
| Stop Bit | 2, 1 |
| Supported BAUD Rates | 9600, 19200, 38400, 57600, 76800, 115200 |
| Supported Protocols | Modbus (using SunSpec IEEE-754 single precision floating point model), or BACnet |
| Voltage Channels | 80 to 346 V AC line-to-neutral, 600 V line-to-line, CAT III |
| Waveform Sampling | 1.8 kHz |