Image is for reference only, refer to product info for complete details.
Designed to give fast, accurate indication of differential pressures. The gage may be used as a readout device when measuring flowing fluids, pressure drop across filters, liquid levels in storage tanks and many other applications involving pressure, vacuum or differential pressure.
Designed to give fast, accurate indication of differential pressures. The gage may be used as a readout device when measuring flowing fluids, pressure drop across filters, liquid levels in storage tanks and many other applications involving pressure, vacuum or differential pressure.
NOTE: May be used with Hydrogen where pressures are less than 35 psi.
Specifications:
Service: Aluminum Case: Air and compatible gases and oil based liquids.
Brass Case: Air and compatible gases and water based liquids.
Wetted Materials: Consult factory.
Housing: Die cast aluminum with impregnated hard coating, standard.
Optional forged brass housing is required for water or water based fluids.Special material diaphragms available, contact factory.
Accuracy: ±3% of full scale at 70°F (21.1°C).
(±2% on 4000S models, ±4% on 4200, 4210, 4215, 4220, 4300, 4400, and 4500).
Pressure Limits: -20" Hg to 500 psig.
(-0.677 bar to 34.4 bar).
Temperature Limits: 20 to 200°F (-6.67 to 93.3°C).
Size: 4" (101.6 mm) diameter dial face.
Mounting Orientation: Diaphragm in vertical position.
Consult factory for other position orientations.
Process Connections: 1/4" female NPT high and low pressure taps, duplicated - one pair top for air and gas, and one pair bottom for liquids.
Weight: 3 lb, 3 oz (1.45 kg) aluminum case; 7 lb, 13 oz (3.54 kg) brass case.
Standard Accessories: Two 1/4" NPT plugs for duplicate pressure taps, four flush mounting adapters with screws and four surface mounting screws.
Earth Resistance Auto Range | 20.00/200.00/1500Ω |
AC Current (50Hz/60Hz) Auto Range | Values are displayed, but accuracy isn't guaranted(600 - 1580Ω) 100.0/1000mA/10.00/30.0A |
Over-Range Indication | "OL" is displayed when input exceeds the upper limit of a measuring range |
Response Time | Approx. 7 seconds (Earth resistance), Approx. 2 seconds (AC Current) |
Sample Rate | Approx. 1 times per second |
Communication Interface | Bluetooth Ver2.1 + EDR Class2 |
Current Consumption | Approx. 50mA (max.100mA) |
Measurement Time | Approx. 5 hours (when R6 is used) Approx. 21 hours (when LR6 is used) |
Auto power-off | Turns power off about 10 minutes after the last button operation |
Conductor Size | Approx.Ø32mm |
Applicable Standards | IEC 61010-1 CAT Ⅳ 300V Pollution degree2, IEC 61010-2-032, IEC 61326 (EMC) |
Power source | DC6V : R6(sizeAA manganese battery) x 4 or LR6 (sizeAA alkaline battery) x 4 |
Dimensions | 246(L)×120(W)×54(D)mm |
Weight | Approx. 780g (including batteries) |
Earth Resistance Auto Range | 20.00/200.00/1500Ω |
AC Current (50Hz/60Hz) Auto Range | Values are displayed, but accuracy isn't guaranted(600 - 1580Ω) 100.0/1000mA/10.00/30.0A |
Over-Range Indication | "OL" is displayed when input exceeds the upper limit of a measuring range |
Response Time | Approx. 7 seconds (Earth resistance), Approx. 2 seconds (AC Current) |
Sample Rate | Approx. 1 times per second |
Communication Interface | Bluetooth Ver2.1 + EDR Class2 |
Current Consumption | Approx. 50mA (max.100mA) |
Measurement Time | Approx. 5 hours (when R6 is used) Approx. 21 hours (when LR6 is used) |
Auto power-off | Turns power off about 10 minutes after the last button operation |
Conductor Size | Approx.Ø32mm |
Applicable Standards | IEC 61010-1 CAT Ⅳ 300V Pollution degree2, IEC 61010-2-032, IEC 61326 (EMC) |
Power source | DC6V : R6(sizeAA manganese battery) x 4 or LR6 (sizeAA alkaline battery) x 4 |
Dimensions | 246(L)×120(W)×54(D)mm |
Weight | Approx. 780g (including batteries) |