Dwyer MS-121 Magnesense Transmitter .1" .25" .5" w.c.

Model: MS-121

Dwyer MS-121 Magnesense Transmitter .1" .25" .5" w.c.

Model: MS-121

Field Upgradeable LCD. No need to order two separate transmitters. Simply stock a transmitter and display and you can satisfy any customer's requests. Simply remove cover and snap the LCD onto the board. Field Selectable Ranges in metric or Engl.

Field Upgradeable LCD. No need to order two separate transmitters. Simply stock a transmitter and display and you can satisfy any customer's requests. Simply remove cover and snap the LCD onto the board. Field Selectable Ranges in metric or Engl.

Discontinued!

This product has been discontinued and is no longer available. There is no direct replacement. Don't worry, we have some options to help you find what you need:

Visit our Differential Transmitters category for similar products.

Or let's do a search and help you find what you need:


Dwyer MS Series Offers

Features

  • Field Upgradeable LCD. No need to order two separate transmitters. Simply stock a transmitter and display and you can satisfy any customer's requests. Simply remove cover and snap the LCD onto the board.
  • Field Selectable Ranges in metric or English. Lowers stock and inventory requirements. You'll always have the right transmitter for every job.
  • Digital Push Button Zero and Span. Reduces calibration time significantly over other transmitters that utilize potentiometers. Lowers maintenance time and costs.
  • Adjustable Digital Dampening smooths out unstable pressure fluctuations common in air flow applications.
  • Field Selectable Air Velocity Mode for fan and blower applications. Unit provides square root output that accurately tracks fpm or m/s flow rate. No need for a smart programmable indicator or PLC to convert pressure to air flow. Reduces components and installation time lowering overall costs.
Functional Specifications
  • Service: Air and non-combustible compatible gases
  • Stability: ±1% F.S./year
  • Temperature Limits: 0 to 150°F (-18 to 66°C)
  • Pressure Limits: 1 psi maximum, operation; 10 psi, burst
  • Output Signals: 4 to 20 mA (2-wire); 0 to 5 V, 0 to 10 V (3-wire)
  • Response Time: Field adjustable 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds
  • Zero & Span Adjustments: Digital push button
  • Loop Resistance: Current Output: 0-1250 max. Voltage Output: min. load resistance 1 k
  • Current Consumption: 40 mA max
  • Display (optional): 4 digit LCD
  • Electrical Entry: 1/2" NPS Thread. Accessory: Cable Gland for 5 to 10 mm diameter cable
  • Process Connection: 3/16" (5 mm) ID tubing. Maximum OD 9 mm
  • Enclosure Rating: NEMA 4X (IP66)
  • Mounting Orientation: Diaphragm in vertical position
General Specifications
  • Power Requirements: 10 to 35 VDC (2-wire)
  • 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire)
  • Weight: 8.0 oz (230 g)

What's included with the Dwyer MS-121

  • Dwyer MS-121 Magnesense Transmitter .1" .25" .5" w.c.

Ask a question about Dwyer MS-121 Magnesense Transmitter .1" .25" .5" w.c.

Customer Reviews for the Dwyer MS-121

Dwyer MS Series Offers

Features

  • Field Upgradeable LCD. No need to order two separate transmitters. Simply stock a transmitter and display and you can satisfy any customer's requests. Simply remove cover and snap the LCD onto the board.
  • Field Selectable Ranges in metric or English. Lowers stock and inventory requirements. You'll always have the right transmitter for every job.
  • Digital Push Button Zero and Span. Reduces calibration time significantly over other transmitters that utilize potentiometers. Lowers maintenance time and costs.
  • Adjustable Digital Dampening smooths out unstable pressure fluctuations common in air flow applications.
  • Field Selectable Air Velocity Mode for fan and blower applications. Unit provides square root output that accurately tracks fpm or m/s flow rate. No need for a smart programmable indicator or PLC to convert pressure to air flow. Reduces components and installation time lowering overall costs.
Functional Specifications
  • Service: Air and non-combustible compatible gases
  • Stability: ±1% F.S./year
  • Temperature Limits: 0 to 150°F (-18 to 66°C)
  • Pressure Limits: 1 psi maximum, operation; 10 psi, burst
  • Output Signals: 4 to 20 mA (2-wire); 0 to 5 V, 0 to 10 V (3-wire)
  • Response Time: Field adjustable 0.5 to 15 sec. time constant. Provides a 95% response time of 1.5 to 45 seconds
  • Zero & Span Adjustments: Digital push button
  • Loop Resistance: Current Output: 0-1250 max. Voltage Output: min. load resistance 1 k
  • Current Consumption: 40 mA max
  • Display (optional): 4 digit LCD
  • Electrical Entry: 1/2" NPS Thread. Accessory: Cable Gland for 5 to 10 mm diameter cable
  • Process Connection: 3/16" (5 mm) ID tubing. Maximum OD 9 mm
  • Enclosure Rating: NEMA 4X (IP66)
  • Mounting Orientation: Diaphragm in vertical position
General Specifications
  • Power Requirements: 10 to 35 VDC (2-wire)
  • 17 to 36 VDC or isolated 21.6 to 33 VAC (3-wire)
  • Weight: 8.0 oz (230 g)

What's included with the Dwyer MS-121

  • Dwyer MS-121 Magnesense Transmitter .1" .25" .5" w.c.

Ask a question about Dwyer MS-121 Magnesense Transmitter .1" .25" .5" w.c.

Customer Reviews for the Dwyer MS-121

More Dwyer Products