Enerac M700 Commercial Combustion Analyzer

Model: M700

Enerac M700 Commercial Combustion Analyzer

Model: M700

M700 Combustion Analyzer is a complete stack and exhaust gas analysis system in the palm of your hand. It measures O2 (0-25%), CO SEM Sensor Dual Range (0-500/2,000 or 0-2,500/10,000ppm), Draft, Combustibles (0-6%), (Dual ranges for CO, SO2 , NO and NO2; (not available if Combustible Sensor is selected) Stack and Ambient Temperature.

M700 Combustion Analyzer is a complete stack and exhaust gas analysis system in the palm of your hand. It measures O2 (0-25%), CO SEM Sensor Dual Range (0-500/2,000 or 0-2,500/10,000ppm), Draft, Combustibles (0-6%), (Dual ranges for CO, SO2 , NO and NO2; (not available if Combustible Sensor is selected) Stack and Ambient Temperature.

Your Price $4495.00 USD
Availability 2 to 3 Weeks
Quantity

Enerac M700 Offers

Features

  • Measures O2 (0-25%), CO SEM Sensor Dual Range (0-500/2,000 or 0-2,500/10,000ppm), Draft, Combustibles (0-6%), (Dual ranges for CO, SO2 , NO and NO2; *not available if Combustible Sensor is selected) Stack and Ambient Temperature
  • Computes Efficiency, CO2 and Excess air
  • Easy to use, easy to calibrate
  • Bright 128 x 64 display
  • High speed graphic printer
  • Interal test storage
  • Computer / PDA interface
  • Auto Zero
  • RS-232 Port
  • USB port
  • Enercom Software
  • Firmware upgrades IN-THE-FIELD
  • Rugged aluminum case
  • Analyzer weighs less than 6 lbs
  • Rechargeable Battery, AC Adapter, Printer (2 inch Wide line printer), Storage (100 Complete Test Printouts), Calibration Certificate
  • Two-Year Warranty on the Unit and a Two-Year Warranty (Pro-Rated) on the Sensors

Top 5 Reasons to Own Enerac M700 Combustion Emissions Analyzer.

Compact/Rugged: Weighs 6 lbs and is easy to operate (no technical expertise is needed). The Enerac 700 combustion emissions analyzers are rugged, made with a metal case, and considered the workhorse of the industry, withstanding years of use and abuse.

Versatile: The most common applications are those related to combustion sources, such as Boilers, Burners, Engines, Turbines, Generators, Kilns, Dryers, Heaters, Ovens, and more. Excellent for combustion/emissions experiments typically found in the University research environment and the private sector.

User Friendly: Enerac 700 has easy access for replacing sensors in the field. These sensors are field-replaceable without returning to the factory for sensor replacement. Free factory tech support is always available.

Compliance Level:

  • The Enerac M700 is fully upgradeable.
  • Features a standard sample conditioning system (thermoelectric condenser, also called a Peltier cooler) necessary for correctly detecting and measuring NO2 and SO2 gasses.
  • Enerac M700 also has proper control over the NO sensor's tendency to drift over time with increasing ambient temperatures.
  • NO SEM sensor incorporates a proprietary temperature control system to automatically hold the nominal filter and sensor temperatures at < 30 degrees C. This ultimately prevents rising measurement data drift and maintains the actual lower readings of the NO (NOx). This prevents one from overstating one's NO (NOx) emissions.
  • The Enerac Model 700 combines high-quality tubing (Viton hose with its specific dimensions and flow rate) and an accurate and reliable conditioning system (Peltier cooler) with the benefits of precise, highly SEM sensors. The result is a Compliance-Level Emissions Analyzer that produces reliable, accurate data.
  • Enerac M700 is perfect for gathering extraordinarily accurate and reliable data for internal needs and the necessary emissions reporting requirements for local, district, county, state, and federal agencies. The Model 700 Is perfect for S.C.A.Q.M.D. compliance requirements (and the other CA districts) EPA compli-ance tests (i.e. ctm 30, ASTM – 6522, ctm 34, for CO, (NOx) requirements), method 2 (stack gas velocity), and method 25B (Hydrocarbons).

Communications: The Enerac 700 comes with 500 internal storage buffers for storing collected data during a testing event. With Enerac’s free Enercom software, one can use it during the testing event or download the stored data later. There is a serial port (RS 232 port), USB port, and Bluetooth for communicating with your Enerac Model 700 and your computer.

Applications

  • Emissions monitoring
  • Fuel energy savings
  • Compliance testing
  • EPA Testing
  • Mobile Engine and Automotive Industry
  • Power Plants
  • Maintenance and tuning of combustion processes such as burners, boilers, diesel and gas engines, laboratory analysis, heaters, kilns, furnaces, and turbines
  • Industrial furnaces, boilers and water heaters

What's included with the Enerac M700

  • Enerac M700 Commercial Combustion Analyzer

Ask a question about Enerac M700 Commercial Combustion Analyzer

Customer Reviews for the Enerac M700

Enerac M700 Offers

Features

  • Measures O2 (0-25%), CO SEM Sensor Dual Range (0-500/2,000 or 0-2,500/10,000ppm), Draft, Combustibles (0-6%), (Dual ranges for CO, SO2 , NO and NO2; *not available if Combustible Sensor is selected) Stack and Ambient Temperature
  • Computes Efficiency, CO2 and Excess air
  • Easy to use, easy to calibrate
  • Bright 128 x 64 display
  • High speed graphic printer
  • Interal test storage
  • Computer / PDA interface
  • Auto Zero
  • RS-232 Port
  • USB port
  • Enercom Software
  • Firmware upgrades IN-THE-FIELD
  • Rugged aluminum case
  • Analyzer weighs less than 6 lbs
  • Rechargeable Battery, AC Adapter, Printer (2 inch Wide line printer), Storage (100 Complete Test Printouts), Calibration Certificate
  • Two-Year Warranty on the Unit and a Two-Year Warranty (Pro-Rated) on the Sensors

Top 5 Reasons to Own Enerac M700 Combustion Emissions Analyzer.

Compact/Rugged: Weighs 6 lbs and is easy to operate (no technical expertise is needed). The Enerac 700 combustion emissions analyzers are rugged, made with a metal case, and considered the workhorse of the industry, withstanding years of use and abuse.

Versatile: The most common applications are those related to combustion sources, such as Boilers, Burners, Engines, Turbines, Generators, Kilns, Dryers, Heaters, Ovens, and more. Excellent for combustion/emissions experiments typically found in the University research environment and the private sector.

User Friendly: Enerac 700 has easy access for replacing sensors in the field. These sensors are field-replaceable without returning to the factory for sensor replacement. Free factory tech support is always available.

Compliance Level:

  • The Enerac M700 is fully upgradeable.
  • Features a standard sample conditioning system (thermoelectric condenser, also called a Peltier cooler) necessary for correctly detecting and measuring NO2 and SO2 gasses.
  • Enerac M700 also has proper control over the NO sensor's tendency to drift over time with increasing ambient temperatures.
  • NO SEM sensor incorporates a proprietary temperature control system to automatically hold the nominal filter and sensor temperatures at < 30 degrees C. This ultimately prevents rising measurement data drift and maintains the actual lower readings of the NO (NOx). This prevents one from overstating one's NO (NOx) emissions.
  • The Enerac Model 700 combines high-quality tubing (Viton hose with its specific dimensions and flow rate) and an accurate and reliable conditioning system (Peltier cooler) with the benefits of precise, highly SEM sensors. The result is a Compliance-Level Emissions Analyzer that produces reliable, accurate data.
  • Enerac M700 is perfect for gathering extraordinarily accurate and reliable data for internal needs and the necessary emissions reporting requirements for local, district, county, state, and federal agencies. The Model 700 Is perfect for S.C.A.Q.M.D. compliance requirements (and the other CA districts) EPA compli-ance tests (i.e. ctm 30, ASTM – 6522, ctm 34, for CO, (NOx) requirements), method 2 (stack gas velocity), and method 25B (Hydrocarbons).

Communications: The Enerac 700 comes with 500 internal storage buffers for storing collected data during a testing event. With Enerac’s free Enercom software, one can use it during the testing event or download the stored data later. There is a serial port (RS 232 port), USB port, and Bluetooth for communicating with your Enerac Model 700 and your computer.

Applications

  • Emissions monitoring
  • Fuel energy savings
  • Compliance testing
  • EPA Testing
  • Mobile Engine and Automotive Industry
  • Power Plants
  • Maintenance and tuning of combustion processes such as burners, boilers, diesel and gas engines, laboratory analysis, heaters, kilns, furnaces, and turbines
  • Industrial furnaces, boilers and water heaters

What's included with the Enerac M700

  • Enerac M700 Commercial Combustion Analyzer

Ask a question about Enerac M700 Commercial Combustion Analyzer

Customer Reviews for the Enerac M700

More Enerac Products